layout | title |
---|---|
documentation |
ZW ESJ 300 - ZWave |
{% include base.html %}
This describes the Z-Wave device ZW ESJ 300, manufactured by Reitz-Group.de with the thing type UID of reitz_zwesj300_00_000
.
The ZW ESJ 300 does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. Refer to the Wakeup Information section below for further information.
The ZW ESJ 300 does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour.
The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device.
The following table summarises the channels available for the ZW ESJ 300 -:
Channel | Channel Id | Category | Item Type |
---|---|---|---|
Switch | switch_binary | Switch | Switch |
Blinds Control | blinds_control | Blinds | Rollershutter |
Switch the power on and off.
The switch_binary
channel supports the Switch
item and is in the Switch
category.
Provides start / stop control of blinds.
The blinds_control
channel supports the Rollershutter
item and is in the Blinds
category.
The following table provides a summary of the 2 configuration parameters available in the ZW ESJ 300. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
0 | Running time | Adjustment of the operating times of the sun blind control |
1 | Stop-functionality | Adjusting the Stop-Functionality |
Switch All Mode | Set the mode for the switch when receiving SWITCH ALL commands |
Adjustment of the operating times of the sun blind control
NOTE: The set values remain stored even after a power failure. The adjustment process of the operating times can be repeated anytime.
NOTE: Should the adjustment of the operating times take place with the help of the configuration tool of a third-party manufacturer, you can consider the following values as the basis: Please note that the adjustments should be undertaken only by well-versed technicians.
0x00 = nointerruption/permanent operation
0x01-0x7F = 1 second to 127 seconds in 1-second steps
0x80-0xFE = 130 seconds (0x80) to 1390 seconds (0xFE) in 10 second-steps
0xFF = factory settings 120 seconds Values in the range 0 to 255 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_0_1
and is of type INTEGER
.
Adjusting the Stop-Functionality 5.2.2 ADJUSTING THE STOP-FUNCTIONALITY:
You can also programm the shutter actuator in a way, that in case of a press in the apposite direction, the shutter won‘t stop, but continue directly in the opposite way (Z-Wave conform). Please proceed as follows:
-
Hold the “UP” and “DOWN” button of the shutter actuator simulaneausly for 5 seconds. Please note, that the devise nust not be included in the network!
-
Alternatively by configuration command (only for adviced users): Set the configuration value “1” to the value “0” in or- der to disable the stop-functionality.
In order to enable the stop-functionality, please proceed as follows:
-
Hold the “UP” and “DOWN” button of the shutter actuator simulaneausly for 5 seconds. Please note, that the devise
nust not be included in the network!
-
Alternatively by configuration command (only for adviced users): Set the configuration value “1” to the value “1” in order
to enable the stop-functionality. The following option values may be configured -:
Value | Description |
---|---|
0 | Disabled |
1 | Enabled (default) |
The manufacturer defined default value is 1
(Enabled (default)).
This parameter has the configuration ID config_1_1
and is of type INTEGER
.
Set the mode for the switch when receiving SWITCH ALL commands.
The following option values may be configured -:
Value | Description |
---|---|
0 | Exclude from All On and All Off groups |
1 | Include in All On group |
2 | Include in All Off group |
255 | Include in All On and All Off groups |
This parameter has the configuration ID switchall_mode
and is of type INTEGER
.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The device does not support associations.
Command Class | Comment |
---|---|
COMMAND_CLASS_SWITCH_BINARY_V1 | |
COMMAND_CLASS_SWITCH_MULTILEVEL_V1 | |
COMMAND_CLASS_SWITCH_ALL_V1 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_PROTECTION_V1 | |
COMMAND_CLASS_HAIL_V1 | |
COMMAND_CLASS_ASSOCIATION_V1 | |
COMMAND_CLASS_VERSION_V1 | |
COMMAND_CLASS_INDICATOR_V1 |
Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.