ZMNHBD Flush 2 relays

This describes the Z-Wave device ZMNHBD, manufactured by Goap with the thing type UID of qubino_zmnhbd_00_000.

The device is in the category of Wall Switch, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch.

ZMNHBD product image

The ZMNHBD supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.

Overview

This Z-Wave module is used for switching on or off two electrical devices (e.g. lights or fans,..). The module can be controlled either through Z-Wave network or through the wallswitches. The module is designed to be mounted inside a "flush mountingbox", hidden behind a traditional wall switch. Module measures power consumption of two electrical devices and supports connection of digital temperature sensor. It is designed to act as repeater in order to improve range and stability of Z-wave network.

Inclusion Information

Module Inclusion (Adding to Z-Wave network)

  • Connect module to power supply (with temperature sensor connected -if purchased)
  • Enable add/remove mode on main controller
  • Auto-inclusion (works forabout 5 seconds after connected to power supply) or
  • Press push button I1 three times within 3s (3 times change switch state within 3 seconds) or
  • Press service button S (only applicable for 24 V SELV supply voltage) for more than 2 seconds.

NOTE1: For auto-inclusion procedure, first set main controller into inclusion mode and then connect module to power supply.

NOTE2: When connecting temperature sensor to module that has already been included, you have to exclude module first. Switch off power supply , connect the sensor and re-include the module.

Exclusion Information

Module Exclusion/Reset (Removing from Z-Wavenetwork)

  • Connect module to power supply
  • Bring module within maximum 1 meter (3 feet) of the main controller,
  • Enable add/remove mode on main controller,
  • Press push button I1 five times within 3s (5 times change switch state within 3 seconds) in the first 60 seconds after the module is connected to the power supply or
  • Press service button S (only applicable for 24 V SELV supply voltage) for more than 6 seconds.

By this function all parameters of the module are set to default values and own ID is deleted.

If push button I1 is pressed three times within 3s (or service button S is pressed more than 2 and less than 6 seconds) module is excluded, but configuration parameters are not set to default values.

Channels

The following table summarises the channels available for the ZMNHBD -:

Channel Channel Id Category Item Type
Switch switch_binary Switch Switch
Sensor (temperature) sensor_temperature Temperature Number:Temperature
Electric meter (watts) meter_watts Energy Number
Electric meter (kWh) meter_kwh Energy Number
Switch 1 switch_binary1 Switch Switch
Electric meter (watts) 1 meter_watts1 Energy Number
Electric meter (kWh) 1 meter_kwh1 Energy Number
Switch 2 switch_binary2 Switch Switch
Electric meter (watts) 2 meter_watts2 Energy Number
Electric meter (kWh) 2 meter_kwh2 Energy Number
Sensor (temperature) sensor_temperature3 Temperature Number:Temperature

Switch

Switch the power on and off.

The switch_binary channel supports the Switch item and is in the Switch category.

Sensor (temperature)

Indicates the current temperature.

The sensor_temperature channel supports the Number:Temperature item and is in the Temperature category.

Electric meter (watts)

Indicates the instantaneous power consumption.

The meter_watts channel supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (kWh)

Indicates the energy consumption (kWh).

The meter_kwh channel supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Switch 1

Switch the power on and off.

The switch_binary1 channel supports the Switch item and is in the Switch category.

Electric meter (watts) 1

Indicates the instantaneous power consumption.

The meter_watts1 channel supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (kWh) 1

Indicates the energy consumption (kWh).

The meter_kwh1 channel supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Switch 2

Switch the power on and off.

The switch_binary2 channel supports the Switch item and is in the Switch category.

Electric meter (watts) 2

Indicates the instantaneous power consumption.

The meter_watts2 channel supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (kWh) 2

Indicates the energy consumption (kWh).

The meter_kwh2 channel supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Sensor (temperature)

Indicates the current temperature.

The sensor_temperature3 channel supports the Number:Temperature item and is in the Temperature category.

Device Configuration

The following table provides a summary of the 17 configuration parameters available in the ZMNHBD. Detailed information on each parameter can be found in the sections below.

Param Name Description
1 Input 1 switch type Input 1 switch type
2 Input 2 switch type Input 2 switch type
10 Functions ALL ON/ALL OFF Activate / deactivate functions ALL ON/ALL OFF
11 Automatic turning off output Q1 after set time When relay Q1 is ON it goes automatically OFF after defined time
12 Automatic turning on output Q1 after set time When relay Q1 is OFF it goes automatically ON after defined time
13 Automatic turning off relay Q2 after set time When relay Q2 is ON it goes automatically OFF after defined time
14 Automatic turning on output Q2 after set time When relay Q2 is OFF it goes automatically ON after defined time
15 Automatic turning off / on seconds or milliseconds selection Automatic turning off / on seconds or milliseconds selection
30 Saving the state after a power failure Saving the state of the relays Q1 and Q2 after a power failure
40 Power reporting in Watts for Q1 Power reporting in Watts on power change for Q1
41 Power reporting in Watts for Q2 Power reporting in Watts on power change for Q2
42 Power reporting time interval for Q1 Power reporting in Watts by time interval for Q1
43 Power reporting time interval for Q2 Power reporting in Watts by time interval for Q2
63 Output Q1 Switch selection
64 Output Q2 Switch selection
110 Temperature sensor offset Temperature sensor offset settings
120 Digital temperature sensor reporting Digital temperature sensor reporting
Switch All Mode Set the mode for the switch when receiving SWITCH ALL commands

Parameter 1: Input 1 switch type

Input 1 switch type

The following option values may be configured -:

Value Description
0 mono-stable switch type (push button)
1 bi-stable switch type

The manufacturer defined default value is 1 (bi-stable switch type).

This parameter has the configuration ID config_1_1 and is of type INTEGER.

Parameter 2: Input 2 switch type

Input 2 switch type

The following option values may be configured -:

Value Description
0 mono-stable switch type (push button)
1 bi-stable switch type

The manufacturer defined default value is 1 (bi-stable switch type).

This parameter has the configuration ID config_2_1 and is of type INTEGER.

Parameter 10: Functions ALL ON/ALL OFF

Activate / deactivate functions ALL ON/ALL OFF Flush 1 relay module responds to commands ALL ON / ALL OFF that may be sent by the main controller or by other controller belonging to the system. The following option values may be configured -:

Value Description
0 ALL ON is not active ALL OFF is not active
1 ALL ON is not active ALL OFF active
2 ALL ON active ALL OFF is not active
255 ALL ON active, ALL OFF active

The manufacturer defined default value is 255 (ALL ON active, ALL OFF active).

This parameter has the configuration ID config_10_2 and is of type INTEGER.

Parameter 11: Automatic turning off output Q1 after set time

When relay Q1 is ON it goes automatically OFF after defined time Timer is reset to zero each time the module receive ON command regardless from where it comes  (push button, associated module, controller,..).

  • 0 - Auto OFF disabled
  • 1 - 32535 = 1second (0,01s) - 32535 seconds (325,35s) Auto OFF enabled with define time, step is 1s or 10ms according to parameter nr.15. Values in the range 0 to 32535 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_11_2 and is of type INTEGER.

Parameter 12: Automatic turning on output Q1 after set time

When relay Q1 is OFF it goes automatically ON after defined time Timer is reset to zero each time the module receive OFF command regardless from where it comes (push button, associated module, controller,..).

  • 0 - Auto ON disabled
  • 1 - 32535 = 1second (0,01s) - 32536 seconds (325,35s) Auto ON enabled with define time, step is 1s or 10ms according to parameter nr.15. Values in the range 0 to 32535 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_12_2 and is of type INTEGER.

Parameter 13: Automatic turning off relay Q2 after set time

When relay Q2 is ON it goes automatically OFF after defined time Timer is reset to zero each time the module receive ON command regardless from where it comes (push button, associated module, controller,..).

  • 0 -Auto OFF disabled
  • 1 - 32535 = 1second (0,01s) - 32535 seconds (325,35s) Auto OFF enabled with define time, step is 1s or 10ms according to parameter nr.15. Values in the range 0 to 32535 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_13_2 and is of type INTEGER.

Parameter 14: Automatic turning on output Q2 after set time

When relay Q2 is OFF it goes automatically ON after defined time Timer is reset to zero each time the module receive OFF command regardless from where it comes (push button, associated module, controller,..).

  • 0 -Auto ON disabled
  • 1 - 32535 = 1second (0,01s) - 32536 seconds (325,35s) Auto ON enabled with define time, step is 1s or 10ms according to parameter nr.15. Values in the range 0 to 32535 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_14_2 and is of type INTEGER.

Parameter 15: Automatic turning off / on seconds or milliseconds selection

Automatic turning off / on seconds or milliseconds selection Available configuration parameters:

  • 0 – seconds selected
  • 1 – milliseconds selected

NOTE: Parameter is valid for both outputs Q1, Q2 and is the same for turning off or on. Values in the range 0 to 255 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_15_1 and is of type INTEGER.

Parameter 30: Saving the state after a power failure

Saving the state of the relays Q1 and Q2 after a power failure

The following option values may be configured -:

Value Description
0 Saves its state before power failure
1 Does not save the state after a power failure

The manufacturer defined default value is 0 (Saves its state before power failure).

This parameter has the configuration ID config_30_1 and is of type INTEGER.

Parameter 40: Power reporting in Watts for Q1

Power reporting in Watts on power change for Q1 Set value means percentage, set value from 0 –100 = 0% -100%.

Available configuration parameters:

  • 0 - reporting disabled
  • 1 -100 = 1% -100% Reporting enabled. Power report is send (push) only when actual power in Watts in real time changes for more than set percentage comparing to previous actual power in Watts, step is 1%.

NOTE: If power changed is less than 1W, the report is not send (pushed), independent of percentage set. Values in the range 0 to 100 may be set.

The manufacturer defined default value is 10.

This parameter has the configuration ID config_40_1 and is of type INTEGER.

Parameter 41: Power reporting in Watts for Q2

Power reporting in Watts on power change for Q2 Set value means percentage, set value from 0 –100 = 0% -100%. Available configuration parameters:

  • 0 - reporting disabled
  • 1 - 100 = 1% - 100% Reporting enabled. Power report is send (push) only when actual power in Watts in real time changes for more than set percentage comparing to previous actual power in Watts, step is 1%.

NOTE: If power changed is less than 1W, the report is not send (pushed), independent of percentage set. Values in the range 0 to 100 may be set.

The manufacturer defined default value is 10.

This parameter has the configuration ID config_41_1 and is of type INTEGER.

Parameter 42: Power reporting time interval for Q1

Power reporting in Watts by time interval for Q1 Set value means time interval (0 – 32535) in seconds, when power report is send. Available configuration parameters:

  • Default value 300 (power report in Watts is send each 300s)
  • 0 - reporting disabled
  • 1 - 32535 = 1 second - 32535 seconds. Reporting enabled, Power report is send with time interval set by entered value. Values in the range 0 to 32535 may be set.

The manufacturer defined default value is 300.

This parameter has the configuration ID config_42_2 and is of type INTEGER.

Parameter 43: Power reporting time interval for Q2

Power reporting in Watts by time interval for Q2 Set value means time interval (0 –32535) in seconds, when power report is send. Available configuration parameters:

  • Default value 300 (power report in Watts is send each 300s)
  • 0 - reporting disabled
  • 1 - 32535 = 1 second - 32535 seconds. Reporting enabled, Power report is send with time interval set by entered value. Values in the range 0 to 32535 may be set.

The manufacturer defined default value is 300.

This parameter has the configuration ID config_43_2 and is of type INTEGER.

Parameter 63: Output Q1 Switch selection

The following option values may be configured -:

Value Description
0 When system is turned off the output is 0V (NC)
1 When system is turned off the output is 230V or 24V (NO)

The manufacturer defined default value is 0 (When system is turned off the output is 0V (NC)).

This parameter has the configuration ID config_63_1 and is of type INTEGER.

Parameter 64: Output Q2 Switch selection

The following option values may be configured -:

Value Description
0 When system is turned off the output is 0V (NC)
1 When system is turned off the output is 230V or 24V (NO)

The manufacturer defined default value is 0 (When system is turned off the output is 0V (NC)).

This parameter has the configuration ID config_64_1 and is of type INTEGER.

Parameter 110: Temperature sensor offset

Temperature sensor offset settings Set value is added or subtracted to actual measured value by sensor. Available configuration parameters:

  • Default value 32536
  • 32536 - offset is 0.0C
  • From 1 to 100 - value from 0.1 °C to 10.0 °C is added to actual measured temperature.
  • From 1001 to 1100 -value from -0.1 °C to -10.0 °C is subtracted to actual measured temperature. Values in the range 0 to 32536 may be set.

The manufacturer defined default value is 32536.

This parameter has the configuration ID config_110_2 and is of type INTEGER.

Parameter 120: Digital temperature sensor reporting

Digital temperature sensor reporting If digital temperature sensor is connected, module reports measured temperature on temperature change defined by this parameter. Available configuration parameters:

  • Default value 5 = 0,5°C
  • 0 – Reporting disabled
  • 1 - 127 = 0,1°C – 12,7°C, step is 0,1°C Values in the range 0 to 127 may be set.

The manufacturer defined default value is 5.

This parameter has the configuration ID config_120_1 and is of type INTEGER.

Switch All Mode

Set the mode for the switch when receiving SWITCH ALL commands.

The following option values may be configured -:

Value Description
0 Exclude from All On and All Off groups
1 Include in All On group
2 Include in All Off group
255 Include in All On and All Off groups

This parameter has the configuration ID switchall_mode and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The ZMNHBD supports 8 association groups.

Group 1: Default Reporting Group

Association group 1 supports 1 node.

Group 2: Q1 basic on/off

Association group 2 supports 16 nodes.

Group 3: Q1 switch binary

Association group 3 supports 16 nodes.

Group 4: Q1 power meter

Association group 4 supports 16 nodes.

Group 5: Q2 basic on/off

Association group 5 supports 16 nodes.

Group 6: Q2 switch binary

Association group 6 supports 16 nodes.

Group 7: Q2 power meter

Association group 7 supports 16 nodes.

Group 8: Multilevel sensor

Association group 8 supports 16 nodes.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_BINARY_V1 Linked to BASIC
COMMAND_CLASS_SWITCH_ALL_V1
COMMAND_CLASS_SENSOR_MULTILEVEL_V7
COMMAND_CLASS_METER_V3
COMMAND_CLASS_MULTI_CHANNEL_V2
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_ASSOCIATION_V1
COMMAND_CLASS_VERSION_V1

Endpoint 1

Command Class Comment
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_BINARY_V1 Linked to BASIC
COMMAND_CLASS_METER_V3
COMMAND_CLASS_ASSOCIATION_V1
COMMAND_CLASS_VERSION_V1

Endpoint 2

Command Class Comment
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_BINARY_V1 Linked to BASIC
COMMAND_CLASS_METER_V3
COMMAND_CLASS_ASSOCIATION_V1
COMMAND_CLASS_VERSION_V1

Endpoint 3

Command Class Comment
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SENSOR_MULTILEVEL_V7 Linked to BASIC
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V2
COMMAND_CLASS_ZWAVEPLUS_INFO_V2
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_VERSION_V2

Documentation Links


Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.