FGWP102 Metered Wall Plug Switch

This describes the Z-Wave device FGWP102, manufactured by Fibargroup with the thing type UID of fibaro_fgwp102_02_001. This version of the device is limited to firmware version 2.1

The device is in the category of Power Outlet, defining Small devices to be plugged into a power socket in a wall which stick there.

FGWP102 product image

The FGWP102 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.

Overview

FIBARO Wall Plug is a universal, Z-Wave Plus compatible, remotely controlled outlet adapter. This device may be applied wherever you want to control electrical devices with up to 2500W load.

The Wall Plug is equipped with a power and energy metering function. It uses a LED ring to visualize the current load with colour changing illumination and operating mode. This is the smallest and most attractive device of this type available in the world.

The Wall Plug may be operated using the B-button located on its casing or via any Z-Wave compatible controller.

Inclusion Information

To add the device to the Z-Wave network:

    Plug the device into a socket nearby the main Z-Wave controller.
    The LED ring will glow red signalling not being added (reset or remove the device otherwise).
    Set the main controller in (security/non-security) add mode (see the controller’s manual).
    Quickly, triple click the B-button located on the casing.
    Wait for the adding process to end.
    Successful adding will be confirmed by the Z-Wave controller’s message.

Exclusion Information

To remove the device from the Z-Wave network:

    Plug the device into a socket nearby the main Z-Wave controller.
    The LED ring will glow green signalling being added (removing is not necessary otherwise).
    Set the main controller into remove mode (see the controller’s manual).
    Quickly, triple click the B-button located on the casing.
    Wait for the removing process to end.
    Successful removing will be confirmed by the Z-Wave controller’s message.

Channels

The following table summarises the channels available for the FGWP102 -:

Channel Channel Id Category Item Type
Switch switch_binary Switch Switch
Sensor (power) sensor_power Energy Number
Electric meter (kWh) meter_kwh Energy Number
Electric meter (watts) meter_watts Energy Number
Reset the total power consumption meter_reset Energy Switch
Alarm alarm_general Door Switch

Switch

Switch the power on and off.

The switch_binary channel supports the Switch item and is in the Switch category.

Sensor (power)

Indicates the energy consumption (kWh).

The sensor_power channel supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (kWh)

Indicates the energy consumption (kWh).

The meter_kwh channel supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (watts)

Indicates the instantaneous power consumption.

The meter_watts channel supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Reset the total power consumption

Reset the meter.

The meter_reset channel supports the Switch item and is in the Energy category.

Alarm

Indicates if an alarm is triggered.

The alarm_general channel supports the Switch item and is in the Door category. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
OFF OK
ON Alarm

Device Configuration

The following table provides a summary of the 19 configuration parameters available in the FGWP102. Detailed information on each parameter can be found in the sections below.

Param Name Description
1 Always on function Stops reacting to alarm frames and B-button pushes
16 Remember device status after power failure Define how the plug reacts after the power supply is back on.
34 Reaction to alarms Alarms to which the Wall Plug will respond
35 Response to alarms Defines responds to alarms (device's status change).
39 Alarm duration Wall Plug's alarm mode duration.
40 Immediate power report Defines how much power load must change to be reported.
42 Standard power load report Defines how much power load must change to be reported,
43 Power reporting frequency Frequence of standard power reports
45 Reporting Changes in energy consumed by controlled devices Required change in power to generate power report.
47 Time Period between reports on power and energy consumption Time between reports in power load not been recorded.
49 Metering energy consumed by the Wall Plug itself. Reports amount of energy consumed by the Wall Plug itself.
50 DOWN value Lower power threshold, used in parameter 52.
51 UP value Upper power threshold, used in parameter 52.
52 Action in case defined power values exceeded Defines the way 2nd association group devices are controlled
60 Power load to make red ring flash violet Red ring flashes violet when parameter 61 is set to 0 or 1.
61 LED color when device is on
62 LED color when device is off
63 LED color when Z Wave alarm
70 Overload safety switch Turns off controlled device in case of exceeding power.

Parameter 1: Always on function

Stops reacting to alarm frames and B-button pushes Once activated, Wall Plug will keep a connected device constantly ON, will stop reacting to alarm frames and B-button push.

'Always on' function turns the Plug into a power and energy meter. The following option values may be configured -:

Value Description
0 Activated
1 Inactive

The manufacturer defined default value is 1 (Inactive).

This parameter has the configuration ID config_1_1 and is of type INTEGER.

Parameter 16: Remember device status after power failure

Define how the plug reacts after the power supply is back on. Define how will the Plug react after the power supply is back on.

Default setting: 1

Available settings:0 - Wall Plug does not memorize its state after a power failure. Connected device will be off after the power supply is reconnected. The following option values may be configured -:

Value Description
0 Do not remember state
1 Remember state before power failure

The manufacturer defined default value is 1 (Remember state before power failure).

This parameter has the configuration ID config_16_1 and is of type INTEGER.

Parameter 34: Reaction to alarms

Alarms to which the Wall Plug will respond Define Z-Wave network alarms to which the Wall Plug will respond.

Default setting: 63

Available settings: 0 - 63

1 - general alarm

2 - smoke alarm

4- CO alarm

8 - CO2 alarm

16 - high temperature alarm Values in the range 0 to 63 may be set.

The manufacturer defined default value is 63.

This parameter has the configuration ID config_34_1 and is of type INTEGER.

Parameter 35: Response to alarms

Defines responds to alarms (device's status change). Parameter defines how the Wall Plug will respond to alarms (device's status change).

Available settings:

0 - no reaction

1 - turn on connected device. LED ring signals an alarm through defined time period (parameter 39) The following option values may be configured -:

Value Description
0 No reaction
1 Turn ON
2 Turn OFF
3 Cycle ON/OFF

The manufacturer defined default value is 0 (No reaction).

This parameter has the configuration ID config_35_1 and is of type INTEGER.

Parameter 39: Alarm duration

Wall Plug's alarm mode duration. Wall Plug's alarm mode duration. If a device sending an alarm frame through the Z-Wave network sets alarm duration as well, this parameter's settings are ignored.Default setting: 600 (seconds).Available settings: 1 - 65535 (seconds) Values in the range 1 to 65535 may be set.

The manufacturer defined default value is 600.

This parameter has the configuration ID config_39_2 and is of type INTEGER.

Parameter 40: Immediate power report

Defines how much power load must change to be reported. Parameter defines by how much power load must change, in percents, to be reported to the main controller, with the highest priority in the Z-Wave network. By default, Fibaro Wall Plug immediately sends power report if the power load changes by 80%. Values in the range 1 to 100 may be set.

The manufacturer defined default value is 80.

This parameter has the configuration ID config_40_1 and is of type INTEGER.

Parameter 42: Standard power load report

Defines how much power load must change to be reported, Parameter defines by how much power load must change, in percents, to be reported to the main controller. By default, Fibaro Wall Plug sends power report if the power load changes by 15%. By default such changes in power load may be reported up to 5 times Values in the range 1 to 100 may be set.

The manufacturer defined default value is 15.

This parameter has the configuration ID config_42_1 and is of type INTEGER.

Parameter 43: Power reporting frequency

Frequence of standard power reports This parameter defines how frequently standard power reports (parameter 42) will be sent. By default Wall Plug sends up to 5 reports each 30 seconds, provided the power load changes by 15%.

Default seting: 30 (s)

Available settings: 1 - 254 Values in the range 1 to 255 may be set.

The manufacturer defined default value is 30.

This parameter has the configuration ID config_43_1 and is of type INTEGER.

Parameter 45: Reporting Changes in energy consumed by controlled devices

Required change in power to generate power report. Defines the required change in power to generate an unsolicited power report.

New, reported energy value is calculated based on last reported value. Default setting: 10 (0,1 kWh).

Available settings: 1 - 254 (0,01kWh - 2,54kWh). Values in the range 1 to 255 may be set.

The manufacturer defined default value is 1.

This parameter has the configuration ID config_45_1 and is of type INTEGER.

Parameter 47: Time Period between reports on power and energy consumption

Time between reports in power load not been recorded. Parameter defines time period between reports sent when changes in power load have not been recorded. By default, if power load changes have not been recorded, reports are sent every hour. Default setting: 3 600 (s)Available settings: 1 - 65534 (s) Values in the range 1 to 65534 may be set.

The manufacturer defined default value is 3600.

This parameter has the configuration ID config_47_2 and is of type INTEGER.

Parameter 49: Metering energy consumed by the Wall Plug itself.

Reports amount of energy consumed by the Wall Plug itself. This parameter determines whether energy metering should include the amount of energy consumed by the Wall Plug itself.

Results are being added to energy consumed by controlled device.

Default setting: INACTIVE The following option values may be configured -:

Value Description
0 Inactive
1 Activated

The manufacturer defined default value is 0 (Inactive).

This parameter has the configuration ID config_49_1 and is of type INTEGER.

Parameter 50: DOWN value

Lower power threshold, used in parameter 52. Lower power threshold, used in parameter 52.

Default setting: 300 (30 W)

Available settings: 0 - 25 000 (0,0W - 2 500W)

DOWN value cannot be higher than a value specified in parameter 51. Values in the range 0 to 65535 may be set.

The manufacturer defined default value is 300.

This parameter has the configuration ID config_50_2 and is of type INTEGER.

Parameter 51: UP value

Upper power threshold, used in parameter 52. Upper power threshold, used in parameter 52.

Default setting: 500 (50 W)

Available settings: 0 - 25 000 (0,0W - 2 500W)

UP value cannot be lower than a value specified in parameter 510 Values in the range 0 to 65535 may be set.

The manufacturer defined default value is 500.

This parameter has the configuration ID config_51_2 and is of type INTEGER.

Parameter 52: Action in case defined power values exceeded

Defines the way 2nd association group devices are controlled Parameter defines the way 2nd association group devices are controlled, depending on the current power load.

Values are defined in parameters 50 and 51.

Available settings:

0 - function inactive

1 - turn the associated devices on The following option values may be configured -:

Value Description
0 Function inactive
1 Turn devices ON when power below DOWN
2 Turn devices OFF when power below DOWN
3 Turn devices ON when power above UP
4 Turn devices OFF when power above UP
5 Turn devices ON power below DOWN, OFF power above UP
6 Devices OFF power below DOWN, ON when power above UP

The manufacturer defined default value is 6 (Devices OFF power below DOWN, ON when power above UP).

This parameter has the configuration ID config_52_1 and is of type INTEGER.

Parameter 60: Power load to make red ring flash violet

Red ring flashes violet when parameter 61 is set to 0 or 1. Function is active only when parameter 61 is set to 0 or 1.

Default setting: 25 000 (2 500W)

Available settings: 1 000 - 32 000 (100W - 3200W). Values in the range 0 to 65535 may be set.

The manufacturer defined default value is 25000.

This parameter has the configuration ID config_60_2 and is of type INTEGER.

Parameter 61: LED color when device is on

The following option values may be configured -:

Value Description
0 LED will use predefined steps depending on power
1 LED will use continuous color depending on power
2 White illumination
3 Red illumination
4 Green illumination
5 Blue illumination
6 Yellow illumination
7 Cyan illumination
8 Magenta illumination
9 NO illumination

The manufacturer defined default value is 1 (LED will use continuous color depending on power).

This parameter has the configuration ID config_61_1 and is of type INTEGER.

Parameter 62: LED color when device is off

The following option values may be configured -:

Value Description
0 LED steps depending on the last power when on
1 White illumination
2 Red illumination
3 Green illumination
4 Blue illumination
5 Yellow illumination
6 Cyan illumination
7 Magenta illumination
8 NO illumination

The manufacturer defined default value is 8 (NO illumination).

This parameter has the configuration ID config_62_1 and is of type INTEGER.

Parameter 63: LED color when Z Wave alarm

The following option values may be configured -:

Value Description
0 No change in color
1 LED flashes RED BLUE WHITE
2 White illumination
3 Red illumination
4 Green illumination
5 Blue illumination
6 Yellow illumination
7 Cyan illumination
8 Magenta illumination
9 NO illumination

The manufacturer defined default value is 1 (LED flashes RED BLUE WHITE).

This parameter has the configuration ID config_63_1 and is of type INTEGER.

Parameter 70: Overload safety switch

Turns off controlled device in case of exceeding power. This function allows for turning off the controlled device in case of exceeding the defined power. Controlled device will be turned off even if 'always on' function is active (parameter 1).

Controlled device can be turned back on via B-button Values in the range 0 to 65535 may be set.

The manufacturer defined default value is 65535.

This parameter has the configuration ID config_70_2 and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The FGWP102 supports 3 association groups.

Group 1: Group 1

Is assigned to the device status – sending command frames to the associated devices whenever the Wall Plug is turned ON or OFF via B-button.

Fibaro Association Group Info

Allows to control 5 regular and 5 multichannel devices per an association group.

Association group 1 supports 10 nodes.

Group 2: Group 2

Is assigned to the measured active power – sending command frames to the associated devices depending on the measured load (configured via advanced parameters 50, 51 and 52).

Fibaro Association Group Info

Allows to control 5 regular and 5 multichannel devices per an association group.

Association group 2 supports 10 nodes.

Group 3: Controller Updates

Reports the device status and allows to assign single device only (the main controller by default).

Fibaro Association Group Info

3rd group is reserved solely for the controller and hence only 1 node can be assigned.

Association group 3 supports 1 node.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_APPLICATION_STATUS_V1
COMMAND_CLASS_SWITCH_BINARY_V1 Linked to BASIC
COMMAND_CLASS_SENSOR_MULTILEVEL_V5
COMMAND_CLASS_METER_V2
COMMAND_CLASS_CRC_16_ENCAP_V1
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1
COMMAND_CLASS_ZWAVEPLUS_INFO_V1
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_ALARM_V1
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_POWERLEVEL_V1
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1
COMMAND_CLASS_ASSOCIATION_V1
COMMAND_CLASS_VERSION_V1
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3

Documentation Links