layout title
documentation
ZW500D - ZWave

{% include base.html %}

ZW500D Dimmer

This describes the Z-Wave device ZW500D, manufactured by Wenzhou MTLC Electric Appliances Co.,Ltd. with the thing type UID of enerwave_zw500d_00_000.

The ZW500D supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.

Overview

No device information is provided in the database. Consider updating the database to improve the documentation.

Channels

The following table summarises the channels available for the ZW500D -:

Channel Channel Id Category Item Type
Dimmer switch_dimmer DimmableLight Dimmer

Dimmer

The brightness channel allows to control the brightness of a light. It is also possible to switch the light on and off.

The switch_dimmer channel supports the Dimmer item and is in the DimmableLight category.

Device Configuration

The following table provides a summary of the 2 configuration parameters available in the ZW500D. Detailed information on each parameter can be found in the sections below.

Param Name Description
1 configure LED light state configure LED light state
2 Reverse installed direction Control if switch up is on or off
Switch All Mode Set the mode for the switch when receiving SWITCH ALL commands

Parameter 1: configure LED light state

configure LED light state 0 = LED off with load on

1 = LED on with load on The following option values may be configured -:

Value Description
0 LED off with load on
1 LED on with load on

The manufacturer defined default value is 0 (LED off with load on).

This parameter has the configuration ID config_1_1 and is of type INTEGER.

Parameter 2: Reverse installed direction

Control if switch up is on or off 0 = normal install, up is on

1 = invert switch The following option values may be configured -:

Value Description
0 normal install - up is on
1 invert switch

The manufacturer defined default value is 0 (normal install - up is on).

This parameter has the configuration ID config_2_1 and is of type INTEGER.

Switch All Mode

Set the mode for the switch when receiving SWITCH ALL commands.

The following option values may be configured -:

Value Description
0 Exclude from All On and All Off groups
1 Include in All On group
2 Include in All Off group
255 Include in All On and All Off groups

This parameter has the configuration ID switchall_mode and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The ZW500D supports 1 association group.

Group 1: Group 1

Association group 1 supports 5 nodes.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_MULTILEVEL_V2 Linked to BASIC
COMMAND_CLASS_SWITCH_ALL_V1
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_ASSOCIATION_V1
COMMAND_CLASS_VERSION_V1

Documentation Links