layout | title |
---|---|
documentation |
RF9517 - ZWave |
{% include base.html %}
This describes the Z-Wave device RF9517, manufactured by Cooper Wiring Devices with the thing type UID of cooper_rf9517_00_000
.
The RF9517 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
Aspire RF Accessory Switch Compatible with Aspire RF switch (RF9501, RF9518) for wireless 3-way control eliminating the need for traditional 3-way wiring (up to 5 locations)
switch will have blinking blue LED when first powered on initiate inclusion mode on controller device press the RF9517 button once RF9517 blue LED should turn solid indicating inclusion.
initiate exclusion mode on controller device press the RF9517 button once RF9517 blue LED should begin blinking indicating inclusion.
The following table summarises the channels available for the RF9517 -:
Channel | Channel Id | Category | Item Type |
---|---|---|---|
Switch | switch_binary | Switch | Switch |
Scene Number | scene_number | Number |
Switch the power on and off.
The switch_binary
channel supports the Switch
item and is in the Switch
category.
Triggers when a scene button is pressed.
The scene_number
channel supports the Number
item.
The following table provides a summary of the 1 configuration parameters available in the RF9517. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
1 | Delayed OFF time | The time in seconds the switch will delay when trigger the delayed off feature |
Switch All Mode | Set the mode for the switch when receiving SWITCH ALL commands |
The time in seconds the switch will delay when trigger the delayed off feature
Values in the range 0 to 255 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_1_1
and is of type INTEGER
.
Set the mode for the switch when receiving SWITCH ALL commands.
The following option values may be configured -:
Value | Description |
---|---|
0 | Exclude from All On and All Off groups |
1 | Include in All On group |
2 | Include in All Off group |
255 | Include in All On and All Off groups |
This parameter has the configuration ID switchall_mode
and is of type INTEGER
.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The RF9517 supports 2 association groups.
Association group 1 supports 5 nodes.
Association group 127 supports 1 node.
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_BINARY_V1 | Linked to BASIC |
COMMAND_CLASS_SWITCH_ALL_V1 | |
COMMAND_CLASS_SCENE_ACTIVATION_V1 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_NODE_NAMING_V1 | |
COMMAND_CLASS_HAIL_V1 | |
COMMAND_CLASS_ASSOCIATION_V1 | |
COMMAND_CLASS_VERSION_V1 | |
COMMAND_CLASS_INDICATOR_V1 |
Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.