layout | title |
---|---|
documentation |
powerSwitch - ZWave |
{% include base.html %}
This describes the Z-Wave device powerSwitch, manufactured by BeNext with the thing type UID of benext_powerswitch_00_000
.
The powerSwitch supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
No device information is provided in the database. Consider updating the database to improve the documentation.
The following table summarises the channels available for the powerSwitch -:
Channel | Channel Id | Category | Item Type |
---|---|---|---|
Switch | switch_binary | Switch | Switch |
Switch the power on and off.
The switch_binary
channel supports the Switch
item and is in the Switch
category.
The following table provides a summary of the 4 configuration parameters available in the powerSwitch. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
1 | Set to Default | Set all configuration values to default values (factory settings) |
4 | Start up with last known socket status | state in what the switch is when power is supplied |
9 | Relay delay time | When the relay is switched it can't be switched again until the configured time has passed |
10 | Led indicator | Show the led compared to the relay state |
Switch All Mode | Set the mode for the switch when receiving SWITCH ALL commands |
Set all configuration values to default values (factory settings) All values (0x00 – 0xFF) except for 0x55 can be used to default all the configuration params . Values in the range 0 to 255 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_1_1
and is of type INTEGER
.
state in what the switch is when power is supplied If 0x01–0xFF: When power applied socket is the state before power was disconnected Values in the range 0 to 255 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_4_1
and is of type INTEGER
.
When the relay is switched it can't be switched again until the configured time has passed Value * 10 milliseconds Values in the range 0 to 0 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_9_1
and is of type INTEGER
.
Show the led compared to the relay state If value is 0: the indicator led is never switched on If value is 1: the indicator led is switched on when relay is switched on If value is 2: the indicator led is switched on when relay is switched off Values in the range 0 to 2 may be set.
The manufacturer defined default value is 1
.
This parameter has the configuration ID config_10_1
and is of type INTEGER
.
Set the mode for the switch when receiving SWITCH ALL commands.
The following option values may be configured -:
Value | Description |
---|---|
0 | Exclude from All On and All Off groups |
1 | Include in All On group |
2 | Include in All Off group |
255 | Include in All On and All Off groups |
This parameter has the configuration ID switchall_mode
and is of type INTEGER
.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The powerSwitch supports 1 association group.
Association group 1 supports 1 node.
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_BINARY_V1 | Linked to BASIC |
COMMAND_CLASS_SWITCH_ALL_V1 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_POWERLEVEL_V1 | |
COMMAND_CLASS_PROTECTION_V1 | |
COMMAND_CLASS_ASSOCIATION_V1 | |
COMMAND_CLASS_VERSION_V1 |
Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.