CC2420 and probably others: CCA_MODE / CCA_HYST not evaluated #45

Open
cmorty opened this issue Sep 4, 2015 · 0 comments
Open

CC2420 and probably others: CCA_MODE / CCA_HYST not evaluated #45

cmorty opened this issue Sep 4, 2015 · 0 comments

Comments

@cmorty
Copy link
Contributor

cmorty commented Sep 4, 2015

Is not evaluated. The default mode is 3 -> Signal strength + data, but only the signal strength is evaluated (mode 1). This can have a significant impact with high CCA thesholds.
CCA_HYST is not evaluated, which however isn't that bad as long as there is no noise-model.