forked from Mierdin/UltimateUCSBuilder
-
Notifications
You must be signed in to change notification settings - Fork 1
/
Copy pathUltimateUCSBuilder.ps1
987 lines (798 loc) · 95 KB
/
UltimateUCSBuilder.ps1
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
670
671
672
673
674
675
676
677
678
679
680
681
682
683
684
685
686
687
688
689
690
691
692
693
694
695
696
697
698
699
700
701
702
703
704
705
706
707
708
709
710
711
712
713
714
715
716
717
718
719
720
721
722
723
724
725
726
727
728
729
730
731
732
733
734
735
736
737
738
739
740
741
742
743
744
745
746
747
748
749
750
751
752
753
754
755
756
757
758
759
760
761
762
763
764
765
766
767
768
769
770
771
772
773
774
775
776
777
778
779
780
781
782
783
784
785
786
787
788
789
790
791
792
793
794
795
796
797
798
799
800
801
802
803
804
805
806
807
808
809
810
811
812
813
814
815
816
817
818
819
820
821
822
823
824
825
826
827
828
829
830
831
832
833
834
835
836
837
838
839
840
841
842
843
844
845
846
847
848
849
850
851
852
853
854
855
856
857
858
859
860
861
862
863
864
865
866
867
868
869
870
871
872
873
874
875
876
877
878
879
880
881
882
883
884
885
886
887
888
889
890
891
892
893
894
895
896
897
898
899
900
901
902
903
904
905
906
907
908
909
910
911
912
913
914
915
916
917
918
919
920
921
922
923
924
925
926
927
928
929
930
931
932
933
934
935
936
937
938
939
940
941
942
943
944
945
946
947
948
949
950
951
952
953
954
955
956
957
958
959
960
961
962
963
964
965
966
967
968
969
970
971
972
973
974
975
976
977
978
979
980
981
982
983
984
985
986
987
#---------------------------------------------------------------------
# Name: UltimateUCSBuilder.ps1
# Author: Matthew Oswalt
# Created: 6/10/2013
# Revision: v0.1 - ALPHA
# Rev. Date:
# Description: A script that starts with a completely blank UCS system and configures it to completion.
# This version of the script is very non-modular and static, but that will change in future versions.
# My goal with this version was to define a workflow first, then in later versions, make it more efficient on a module-by-module basis.
#
# Disclaimer: The vast majority of this script is original material, created entirely by me, Matt Oswalt. There are, portions taken from online sources, and although they too
# have been changed to meet my needs, I want to make sure I'm giving credit where it is due, which I will do to the best of my ability.
#
#---------------------------------------------------------------------
#region Imports and Connection
################################################################################################################################
### IMPORTS AND CONNECTION ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
################################################################################################################################
Import-Module CiscoUcsPs
#Import-Module "$pwDir\CustomFunctions.psm1" -- To be implemented later
#Used with the UCS Emulator available at: http://developer.cisco.com/web/unifiedcomputing/ucsemulatordownload
$ucsm_mgmt_address = "10.12.0.109"
$ucsmUsername = "config"
$ucsmPass = "config"
$ucsmSecPass = ConvertTo-SecureString $ucsmPass -AsPlainText -Force
$ucsmCreds = New-Object System.Management.Automation.PSCredential($ucsmUsername, $ucsmSecPass)
## $csv_file = "config\fpod.csv"
#$config = Read-FPodConfig($csv_file) -- To be implemented later
## Make sure no other connection is active
Disconnect-Ucs
## Connect
Connect-Ucs $ucsm_mgmt_address -Credential $ucsmCreds
#endregion
#region Vars and Constants
################################################################################################################################
### VARS ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
################################################################################################################################
$mgmt_ippoolstart = "10.12.0.150"
$mgmt_ippoolfinish = "10.12.0.254"
$mgmt_ippoolgw = "10.12.0.1"
$organization = "SUBORG_01"
$Elapsed = [System.Diagnostics.Stopwatch]::StartNew()
#Set present working directory - to refer to files alongside the script
$scriptpath = $MyInvocation.MyCommand.Path
$pwDir = Split-Path $scriptpath
<#
These vars to be implemented later
$ntp1 = "ntp1.domain.com"
$ntp2 = "ntp2.domain.com"
$snmpcomm = "readonlycommunity"
$snmplocation = "Datacenter Customer Location"
$traphost1 = "10.0.0.100"
$traphost2 = "10.0.0.101"
$fabavsan = "VSAN_4"
$fabavsanid = "4"
$fabbvsan = "VSAN_5"
$fabbvsanid = "5"
$customerportgroup = "Guest_VLAN"
#>
#############################
## Constants ##
#############################
## Variables from config
<#
To be implemented later - taken from Netapp's Flexpod Automation Suite
$VAR_UCSM_INFRA_ORG_NAME = $config.Get_Item("<<var_ucsm_infra_org_name>>")
$VAR_UCSM_MAC_POOL_A_START = $config.Get_Item("<<var_ucsm_mac_pool_A_start>>")
$VAR_UCSM_MAC_POOL_B_START = $config.Get_Item("<<var_ucsm_mac_pool_B_start>>")
$MAC_POOL_A_NAME = "MAC_Pool_A"
$MAC_POOL_B_NAME = "MAC_Pool_B"
$NUMBER_OF_MAC_ADDRS = 33
$WWNN_POOL_NAME = "WWNNPool"
$WWNN_POOL_START = "20:00:00:25:B5:00:00:00"
$WWNN_POOL_END = "20:00:00:25:B5:00:00:20"
$WWPN_POOL_A_NAME = "WWPN_Pool_A"
$WWPN_POOL_B_NAME = "WWPN_Pool_B"
$WWPN_POOL_A_START = "20:00:00:25:B5:00:0A:00"
$WWPN_POOL_A_END = "20:00:00:25:B5:00:0A:3F"
$WWPN_POOL_B_START = "20:00:00:25:B5:00:0B:00"
$WWPN_POOL_B_END = "20:00:00:25:B5:00:0B:3F"
$VSAN_A_NAME = "VSAN_A"
$VSAN_B_NAME = "VSAN_B"
$NCP_NAME = "Net_Ctrl_Policy"
$BEST_EFFORT_MTU = 9000
$VNIC_A_NAME = "vNIC_A"
$VNIC_B_NAME = "vNIC_B"
$VNIC_TEMPLATE_A_NAME = "vNIC_Template_A"
$VNIC_TEMPLATE_B_NAME = "vNIC_Template_B"
$VHBA_A_NAME = "vHBA_A"
$VHBA_B_NAME = "vHBA_B"
$VHBA_TEMPLATE_A_NAME = "vHBA_Template_A"
$VHBA_TEMPLATE_B_NAME = "vHBA_Template_B"
$SERVER_POOL_NAME = "Infra-Pool"
$UUID_POOL_NAME = "UUID_Pool"
$UUID_POOL_START = "0000-000000000001"
$UUID_POOL_END = "0000-000000000064"
$FIBER_CHANNEL_SWITCHING_MODE = "end-host"
#If you want to change any of these to constants (to prevent inadvertent changing), use below:
#Set-Variable FIBER_CHANNEL_SWITCHING_MODE -Option ReadOnly
## Array to loop through both switches
$switchIds_a = "A", "B"
## Match vLan names to ids taken from config
$NAMES_TO_VLANS = @{"MGMT-VLAN" = $config.Get_Item("<<var_global_mgmt_vlan_id>>");
"NFS-VLAN" = $config.Get_Item("<<var_global_nfs_vlan_id>>");
"vMotion-VLAN" = $config.Get_Item("<<var_global_vmotion_vlan_id>>");
"Pkt-Ctrl-VLAN" = $config.Get_Item("<<var_global_packet_control_vlan_id>>");
"VM-Traffic-VLAN" = $config.Get_Item("<<var_global_vm_traffic_vlan_id>>");
"Native-VLAN" = $config.Get_Item("<<var_global_native_vlan_id>>");}
#>
#endregion
#region Infrastructure
<# ### Infrastruction section - work in progress, not ready for this version of the script ###
################################################################################################################################
### INFRASTRUCTURE ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
################################################################################################################################
# This section is based off of a script that I found on the internet, and I can't remember where.
# It will be used in a future version of the script, but rewritten to utilize stored values and loops, rather than static entries on a port-by-port basis.
#Add UCS FI Uplinks on FIA and FIB
add-ucsuplinkport -filancloud A -portid 17 -slotid 1
add-ucsuplinkport -filancloud A -portid 18 -slotid 1
add-ucsuplinkport -filancloud B -portid 17 -slotid 1
add-ucsuplinkport -filancloud B -portid 18 -slotid 1
#Add UCS FI Server Uplinks on FIA and FIB
add-ucsserverport -fabricservercloud A -portid 1 -slotid 1
....
add-ucsserverport -fabricservercloud A -portid 4 -slotid 1
add-ucsserverport -fabricservercloud B -portid 1 -slotid 1
....
add-ucsserverport -fabricservercloud B -portid 4 -slotid 1
#Configre Unified Ports to all be FC
Get-UcsFiSanCloud -Id “A” | Add-UcsFcUplinkPort -ModifyPresent -AdminState “enabled” -SlotId 2 -PortId 1
.......
Get-UcsFiSanCloud -Id “A” | Add-UcsFcUplinkPort -ModifyPresent -AdminState “enabled” -SlotId 2 -PortId 16
Get-UcsFiSanCloud -Id “B” | Add-UcsFcUplinkPort -ModifyPresent -AdminState “enabled” -SlotId 2 -PortId 1
.......
Get-UcsFiSanCloud -Id “B” | Add-UcsFcUplinkPort -ModifyPresent -AdminState “enabled” -SlotId 2 -PortId 16
#CONFIGURE SAN PORTS TO VSAN
get-ucsvsan $fabavsan | add-UcsVsanMemberFcPort -portid 13 -slotid 2 -adminstate enabled -switchid A -modifypresent:$true
...
get-ucsvsan $fabavsan | add-UcsVsanMemberFcPort -portid 16 -slotid 2 -adminstate enabled -switchid A -modifypresent:$true
get-ucsvsan $fabbvsan | add-UcsVsanMemberFcPort -portid 13 -slotid 2 -adminstate enabled -switchid B -modifypresent:$true
...
get-ucsvsan $fabbvsan | add-UcsVsanMemberFcPort -portid 16 -slotid 2 -adminstate enabled -switchid B -modifypresent:$true
#>
#CREATE VLANS
##It is important to give all VLANs names in this part of the script, as the "name" parameter is used later when creating vNICs. Future iterations will not have this requirement.
Get-UcsLanCloud | Add-UcsVlan -Name ESX_MGMT -Id 100
Get-UcsLanCloud | Add-UcsVlan -Name ESX_VMOTION -Id 110
Get-UcsLanCloud | Add-UcsVlan -Name IP_Storage -Id 120
Get-UcsLanCloud | Add-UcsVlan -Name Prod_VM_Traffic -Id 210
Get-UcsLanCloud | Add-UcsVlan -Name NonP_VM_Traffic -Id 220
Get-UcsLanCloud | Add-UcsVlan -Name Prod_Bare_Traffic -Id 230
Get-UcsLanCloud | Add-UcsVlan -Name NonP_Bare_Traffic -Id 240
#CREATE VSANS
Get-UcsFiSanCloud -Id A | Add-UcsVsan -Name VSAN_PROD_A -Id 2100 -fcoevlan 2100 -zoningstate disabled
Get-UcsFiSanCloud -Id A | Add-UcsVsan -Name VSAN_NONP_A -Id 2110 -fcoevlan 2110 -zoningstate disabled
Get-UcsFiSanCloud -Id B | Add-UcsVsan -Name VSAN_PROD_B -Id 2200 -fcoevlan 2200 -zoningstate disabled
Get-UcsFiSanCloud -Id B | Add-UcsVsan -Name VSAN_NONP_B -Id 2210 -fcoevlan 2210 -zoningstate disabled
$rootOrg = Get-UcsOrg -Level root
$result = Get-UcsOrg -Org $rootOrg -Name $organization
if(!$result) {
$ourOrg = Add-UcsOrg -Org $rootOrg -Name $organization
} else {
Write-host "Organization $organization already exists, skipping"
$ourOrg = $result
}
Clear-Variable $result
#endregion
#region Resource Pools
################################################################################################################################
### RESOURCE POOLS ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
################################################################################################################################
#ADD Managment IP Pool Block
add-ucsippoolblock -IpPool "ext-mgmt" -from $mgmt_ippoolstart -to $mgmt_ippoolfinish -defgw $mgmt_ippoolgw -modifypresent:$true
#create UUID pools
$uuidPool = Add-UcsUuidSuffixPool -Org $organization -Name "UUID-ESX-PROD" -AssignmentOrder "sequential" -Descr "Production ESXi" -Prefix derived
Add-UcsUuidSuffixBlock -UuidSuffixPool $uuidPool -From "0000-25B511EE0000" -To "0000-25B511EE00FF"
$uuidPool = Add-UcsUuidSuffixPool -Org $organization -Name "UUID-ESX-NONP" -AssignmentOrder "sequential" -Descr "Production ESXi" -Prefix derived
Add-UcsUuidSuffixBlock -UuidSuffixPool $uuidPool -From "0000-25B511EE1000" -To "0000-25B511EE10FF"
$uuidPool = Add-UcsUuidSuffixPool -Org $organization -Name "UUID-BARE-PROD" -AssignmentOrder "sequential" -Descr "Production ESXi" -Prefix derived
Add-UcsUuidSuffixBlock -UuidSuffixPool $uuidPool -From "0000-25B511BB0000" -To "0000-25B511BB00FF"
$uuidPool = Add-UcsUuidSuffixPool -Org $organization -Name "UUID-BARE-NONP" -AssignmentOrder "sequential" -Descr "Production ESXi" -Prefix derived
Add-UcsUuidSuffixBlock -UuidSuffixPool $uuidPool -From "0000-25B511BB1000" -To "0000-25B511BB10FF"
#create MAC pools
$macPool = Add-UcsMacPool -Org $organization -Name "MAC-ESX-PROD-A" -AssignmentOrder "sequential" -Descr "Production ESXi Fabric A"
Add-UcsMacMemberBlock -MacPool $macPool -From "00:25:B5:11:00:00" -To "00:25:B5:11:00:FF"
$macPool = Add-UcsMacPool -Org $organization -Name "MAC-BARE-PROD-A" -AssignmentOrder "sequential" -Descr "Production Baremetal Fabric A"
Add-UcsMacMemberBlock -MacPool $macPool -From "00:25:B5:11:10:00" -To "00:25:B5:11:10:FF"
$macPool = Add-UcsMacPool -Org $organization -Name "MAC-ESX-NONP-A" -AssignmentOrder "sequential" -Descr "Non-Prod ESXi Fabric A"
Add-UcsMacMemberBlock -MacPool $macPool -From "00:25:B5:11:20:00" -To "00:25:B5:11:20:FF"
$macPool = Add-UcsMacPool -Org $organization -Name "MAC-BARE-NONP-A" -AssignmentOrder "sequential" -Descr "Non-Prod Baremetal Fabric A"
Add-UcsMacMemberBlock -MacPool $macPool -From "00:25:B5:11:30:00" -To "00:25:B5:11:30:FF"
$macPool = Add-UcsMacPool -Org $organization -Name "MAC-ESX-PROD-B" -AssignmentOrder "sequential" -Descr "Production ESXi Fabric B"
Add-UcsMacMemberBlock -MacPool $macPool -From "00:25:B5:11:40:00" -To "00:25:B5:11:40:FF"
$macPool = Add-UcsMacPool -Org $organization -Name "MAC-BARE-PROD-B" -AssignmentOrder "sequential" -Descr "Production Baremetal Fabric B"
Add-UcsMacMemberBlock -MacPool $macPool -From "00:25:B5:11:50:00" -To "00:25:B5:11:50:FF"
$macPool = Add-UcsMacPool -Org $organization -Name "MAC-ESX-NONP-B" -AssignmentOrder "sequential" -Descr "Non-Prod ESXi Fabric B"
Add-UcsMacMemberBlock -MacPool $macPool -From "00:25:B5:11:60:00" -To "00:25:B5:11:60:FF"
$macPool = Add-UcsMacPool -Org $organization -Name "MAC-BARE-NONP-B" -AssignmentOrder "sequential" -Descr "Non-Prod Baremetal Fabric B"
Add-UcsMacMemberBlock -MacPool $macPool -From "00:25:B5:11:70:00" -To "00:25:B5:11:70:FF"
#create WWPN pools
$wwnPool = Add-UcsWwnPool -Org $organization -Name "WWPN-ESX-PROD-A" -AssignmentOrder "sequential" -Purpose "port-wwn-assignment" -Descr "Production ESXi Fabric A"
Add-UcsWwnMemberBlock -wwnPool $wwnPool -From "20:00:00:25:B5:11:00:00" -To "20:00:00:25:B5:11:00:FF"
$wwnPool = Add-UcsWwnPool -Org $organization -Name "WWPN-BARE-PROD-A" -AssignmentOrder "sequential" -Purpose "port-wwn-assignment" -Descr "Production Baremetal Fabric A"
Add-UcsWwnMemberBlock -wwnPool $wwnPool -From "20:00:00:25:B5:11:10:00" -To "20:00:00:25:B5:11:10:FF"
$wwnPool = Add-UcsWwnPool -Org $organization -Name "WWPN-ESX-NONP-A" -AssignmentOrder "sequential" -Purpose "port-wwn-assignment" -Descr "Non-Prod ESXi Fabric A"
Add-UcsWwnMemberBlock -wwnPool $wwnPool -From "20:00:00:25:B5:11:20:00" -To "20:00:00:25:B5:11:20:FF"
$wwnPool = Add-UcsWwnPool -Org $organization -Name "WWPN-BARE-NONP-A" -AssignmentOrder "sequential" -Purpose "port-wwn-assignment" -Descr "Non-Prod Baremetal Fabric A"
Add-UcsWwnMemberBlock -wwnPool $wwnPool -From "20:00:00:25:B5:11:30:00" -To "20:00:00:25:B5:11:30:FF"
$wwnPool = Add-UcsWwnPool -Org $organization -Name "WWPN-ESX-PROD-B" -AssignmentOrder "sequential" -Purpose "port-wwn-assignment" -Descr "Production ESXi Fabric B"
Add-UcsWwnMemberBlock -wwnPool $wwnPool -From "20:00:00:25:B5:11:40:00" -To "20:00:00:25:B5:11:40:FF"
$wwnPool = Add-UcsWwnPool -Org $organization -Name "WWPN-BARE-PROD-B" -AssignmentOrder "sequential" -Purpose "port-wwn-assignment" -Descr "Production Baremetal Fabric B"
Add-UcsWwnMemberBlock -wwnPool $wwnPool -From "20:00:00:25:B5:11:50:00" -To "20:00:00:25:B5:11:50:FF"
$wwnPool = Add-UcsWwnPool -Org $organization -Name "WWPN-ESX-NONP-B" -AssignmentOrder "sequential" -Purpose "port-wwn-assignment" -Descr "Non-Prod ESXi Fabric B"
Add-UcsWwnMemberBlock -wwnPool $wwnPool -From "20:00:00:25:B5:11:60:00" -To "20:00:00:25:B5:11:60:FF"
$wwnPool = Add-UcsWwnPool -Org $organization -Name "WWPN-BARE-NONP-B" -AssignmentOrder "sequential" -Purpose "port-wwn-assignment" -Descr "Non-Prod Baremetal Fabric B"
Add-UcsWwnMemberBlock -wwnPool $wwnPool -From "20:00:00:25:B5:11:70:00" -To "20:00:00:25:B5:11:70:FF"
#create WWNN pools
$wwnPool = Add-UcsWwnPool -Org $organization -Name "WWNN-ESX-PROD" -AssignmentOrder "sequential" -Purpose "node-wwn-assignment" -Descr "Production ESXi"
Add-UcsWwnMemberBlock -wwnPool $wwnPool -From "20:00:00:25:B5:11:A0:00" -To "20:00:00:25:B5:11:A0:FF"
$wwnPool = Add-UcsWwnPool -Org $organization -Name "WWNN-BARE-PROD" -AssignmentOrder "sequential" -Purpose "node-wwn-assignment" -Descr "Production Baremetal"
Add-UcsWwnMemberBlock -wwnPool $wwnPool -From "20:00:00:25:B5:11:B0:00" -To "20:00:00:25:B5:11:B0:FF"
$wwnPool = Add-UcsWwnPool -Org $organization -Name "WWNN-ESX-NONP" -AssignmentOrder "sequential" -Purpose "node-wwn-assignment" -Descr "Non-Prod ESXi"
Add-UcsWwnMemberBlock -wwnPool $wwnPool -From "20:00:00:25:B5:11:C0:00" -To "20:00:00:25:B5:11:C0:FF"
$wwnPool = Add-UcsWwnPool -Org $organization -Name "WWNN-BARE-NONP" -AssignmentOrder "sequential" -Purpose "node-wwn-assignment" -Descr "Non-Prod Baremetal"
Add-UcsWwnMemberBlock -wwnPool $wwnPool -From "20:00:00:25:B5:11:D0:00" -To "20:00:00:25:B5:11:D0:FF"
#create server pools
Add-UcsServerPool -Org $organization -Name "B230-POOL" -Descr "B230 Servers (Vmware)"
Add-UcsServerPool -Org $organization -Name "B200-512-POOL" -Descr "B200 M3 Servers (Windows-SQL)"
Add-UcsServerPool -Org $organization -Name "B200-256-POOL" -Descr "B200 M3 Servers (Vmware)"
Add-UcsServerPool -Org $organization -Name "B420-POOL" -Descr "B420 Servers (Windows-SQL)"
#endregion
#region Policies...
################################################################################################################################
### POLICIES ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
################################################################################################################################
#Set Chassis Discovery Policy
Get-UcsChassisDiscoveryPolicy | Set-UcsChassisDiscoveryPolicy -Action 4-link -LinkAggregationPref port-channel -Rebalance immediate -Force
#Set Power Control Policy
Get-UcsPowerControlPolicy | Set-UcsPowerControlPolicy -Redundancy grid -Force
#Set MAC Aging Policy
get-ucslancloud | set-ucslancloud -macaging mode-default -force
#Set Global Power Allocation Policy
#NOTWORKING - set-ucspowergroup does not modify this... cannot find within PowerTool
#CONFIGURE QOS
get-ucsqosclass platinum | set-ucsqosclass -mtu 1500 -Force -Adminstate disabled
get-ucsqosclass gold | set-ucsqosclass -mtu 1500 -Force -Adminstate disabled
get-ucsqosclass silver | set-ucsqosclass -mtu 9000 -Force -Adminstate enabled
get-ucsqosclass bronze | set-ucsqosclass -mtu 9000 -Force -Adminstate enabled
get-ucsqosclass best-effort | set-ucsqosclass -mtu 1500 -Force -Adminstate enabled
#Configure NTP
#add-ucsntpserver -name $ntp1
#add-ucsntpserver -name $ntp2
#Configure TimeZone
#set-ucstimezone -timezone "America/New_York (Eastern Time)" -Force
#Configure SNMP Community
#set-ucssnmp -community $snmpcomm -syscontact ENOC -syslocation $snmplocation -adminstate enabled -force
#Configure SNMP Traps
#add-ucssnmptrap -hostname $traphost1 -community $snmpcomm -notificationtype traps -port 162 -version v2c
#add-ucssnmptrap -hostname $traphost2 -community $snmpcomm -notificationtype traps -port 162 -version v2c
#Create QOS Policies
Start-UcsTransaction
$mo = Get-UcsOrg -Name $organization | Add-UcsQosPolicy -Name BE
$mo_1 = $mo | Add-UcsVnicEgressPolicy -ModifyPresent -Burst 10240 -HostControl none -Prio "best-effort" -Rate line-rate
Complete-UcsTransaction
Start-UcsTransaction
$mo = Get-UcsOrg -Name $organization | Add-UcsQosPolicy -Name Bronze
$mo_1 = $mo | Add-UcsVnicEgressPolicy -ModifyPresent -Burst 10240 -HostControl none -Prio "bronze" -Rate line-rate
Complete-UcsTransaction
Start-UcsTransaction
$mo = Get-UcsOrg -Name $organization | Add-UcsQosPolicy -Name Gold
$mo_1 = $mo | Add-UcsVnicEgressPolicy -ModifyPresent -Burst 10240 -HostControl none -Prio "gold" -Rate line-rate
Complete-UcsTransaction
Start-UcsTransaction
$mo = Get-UcsOrg -Name $organization | Add-UcsQosPolicy -Name Platinum
$mo_1 = $mo | Add-UcsVnicEgressPolicy -ModifyPresent -Burst 10240 -HostControl none -Prio "platinum" -Rate line-rate
Complete-UcsTransaction
Start-UcsTransaction
$mo = Get-UcsOrg -Name $organization | Add-UcsQosPolicy -Name Silver
$mo_1 = $mo | Add-UcsVnicEgressPolicy -ModifyPresent -Burst 10240 -HostControl none -Prio "silver" -Rate line-rate
Complete-UcsTransaction
#Server Pool Qualification Policies and map to Server Pool
$SPQname = "B200-ODDBALL"
$poolDN = "org-root/org-" + $organization + "/compute-pool-B200-ODDBALL"
$SPQ = Add-UcsServerPoolQualification -Org $organization -Name $SPQname
$SPQ | Add-UcsCpuQualification -Model "UCS-CPU-E5-2665"
Add-UcsServerPoolPolicy -Org $organization -Name "B200-ODDBALL" -Qualifier $SPQname -PoolDN $poolDN
$SPQname = "B200-512-QUAL"
$poolDN = "org-root/org-" + $organization + "/compute-pool-B200-512-POOL"
$SPQ = Add-UcsServerPoolQualification -Org $organization -Name $SPQname
$SPQ | Add-UcsCpuQualification -Model "UCS-CPU-E5-2680"
$SPQ | Add-UcsMemoryQualification -Units 32
Add-UcsServerPoolPolicy -Org $organization -Name "B200-512-PLCY" -Qualifier $SPQname -PoolDN $poolDN
$SPQname = "B200-256-QUAL"
$poolDN = "org-root/org-" + $organization + "/compute-pool-B200-256-POOL"
$SPQ = Add-UcsServerPoolQualification -Org $organization -Name $SPQname
$SPQ | Add-UcsCpuQualification -Model "UCS-CPU-E5-2680"
$SPQ | Add-UcsMemoryQualification -Units 16
Add-UcsServerPoolPolicy -Org $organization -Name "B200-256-PLCY" -Qualifier $SPQname -PoolDN $poolDN
$SPQname = "B420-QUAL"
$poolDN = "org-root/org-" + $organization + "/compute-pool-B420-POOL"
$SPQ = Add-UcsServerPoolQualification -Org $organization -Name $SPQname
$SPQ | Add-UcsCpuQualification -Model "UCS-CPU-E5-4610"
Add-UcsServerPoolPolicy -Org $organization -Name "B420-PLCY" -Qualifier $SPQname -PoolDN $poolDN
$SPQname = "B230-QUAL"
$poolDN = "org-root/org-" + $organization + "/compute-pool-B230-POOL"
$SPQ = Add-UcsServerPoolQualification -Org $organization -Name $SPQname
$SPQ | Add-UcsCpuQualification -Model "UCS-CPU-E72870"
Add-UcsServerPoolPolicy -Org $organization -Name "B230-PLCY" -Qualifier $SPQname -PoolDN $poolDN
#Create blank host firmware package as a placeholder - must manually configure if you want this to do anything.
#More functionality in later versions.
Add-UcsFirmwareComputeHostPack -Org $organization -Name HOSTFW_PLCY
<# Need to flush out host firmware package creation here
$host_firm_pack = Add-UcsFirmwareComputeHostPack -Name host_firm_pack -IgnoreCompCheck no
$host_firm_pack | Add-UcsFirmwarePackItem -Type adaptor -HwModel N20-AC0002 -HwVendor "Cisco Systems Inc" -Version '1.4(1i)'
$host_firm_pack | Get-UcsFirmwarePackItem -HwModel N20-AC0002 | Set-UcsFirmwarePackItem -Version '2.0(1t)'
http://www.cisco.com/en/US/docs/unified_computing/ucs/sw/msft_tools/powertools/ucs_powertool_book/ucs_pwrtool_bkl1.html#wp439024
#>
#IMPORTANT - Add UCS Maintenance Policy for user-ack. Need to map all SPs or SPTs to this policy
Add-UcsMaintenancePolicy -Org $organization -Name "MAINT-USER-ACK" -UptimeDisr user-ack
#Add Boot Policies
$bp = Add-UcsBootPolicy -Org $organization -Name "BFS-ESX-PROD" -EnforceVnicName yes
$bp | Add-UcsLsBootVirtualMedia -Access "read-only" -Order "1"
$bootstorage = $bp | Add-UcsLsbootStorage -ModifyPresent -Order "2"
$bootsanimage = $bootstorage | Add-UcsLsbootSanImage -Type "primary" -VnicName "ESX-PROD-A"
$bootsanimage | Add-UcsLsbootSanImagePath -Lun 0 -Type "primary" -Wwn "50:00:00:00:00:00:00:00"
$bootsanimage | Add-UcsLsbootSanImagePath -Lun 0 -Type "secondary" -Wwn "50:00:00:00:00:00:00:00"
$bootsanimage = $bootstorage | Add-UcsLsbootSanImage -Type "secondary" -VnicName "ESX-PROD-B"
$bootsanimage | Add-UcsLsbootSanImagePath -Lun 0 -Type "primary" -Wwn "50:00:00:00:00:00:00:00"
$bootsanimage | Add-UcsLsbootSanImagePath -Lun 0 -Type "secondary" -Wwn "50:00:00:00:00:00:00:00"
$bp = Add-UcsBootPolicy -Org $organization -Name "BFS-ESX-NONP" -EnforceVnicName yes
$bp | Add-UcsLsBootVirtualMedia -Access "read-only" -Order "1"
$bootstorage = $bp | Add-UcsLsbootStorage -ModifyPresent -Order "2"
$bootsanimage = $bootstorage | Add-UcsLsbootSanImage -Type "primary" -VnicName "ESX-NONP-A"
$bootsanimage | Add-UcsLsbootSanImagePath -Lun 0 -Type "primary" -Wwn "50:00:00:00:00:00:00:00"
$bootsanimage | Add-UcsLsbootSanImagePath -Lun 0 -Type "secondary" -Wwn "50:00:00:00:00:00:00:00"
$bootsanimage = $bootstorage | Add-UcsLsbootSanImage -Type "secondary" -VnicName "ESX-NONP-B"
$bootsanimage | Add-UcsLsbootSanImagePath -Lun 0 -Type "primary" -Wwn "50:00:00:00:00:00:00:00"
$bootsanimage | Add-UcsLsbootSanImagePath -Lun 0 -Type "secondary" -Wwn "50:00:00:00:00:00:00:00"
$bp = Add-UcsBootPolicy -Org $organization -Name "BFS-BARE-PROD" -EnforceVnicName yes
$bp | Add-UcsLsBootVirtualMedia -Access "read-only" -Order "1"
$bootstorage = $bp | Add-UcsLsbootStorage -ModifyPresent -Order "2"
$bootsanimage = $bootstorage | Add-UcsLsbootSanImage -Type "primary" -VnicName "BARE-PROD-A"
$bootsanimage | Add-UcsLsbootSanImagePath -Lun 0 -Type "primary" -Wwn "50:00:00:00:00:00:00:00"
$bootsanimage | Add-UcsLsbootSanImagePath -Lun 0 -Type "secondary" -Wwn "50:00:00:00:00:00:00:00"
$bootsanimage = $bootstorage | Add-UcsLsbootSanImage -Type "secondary" -VnicName "BARE-PROD-B"
$bootsanimage | Add-UcsLsbootSanImagePath -Lun 0 -Type "primary" -Wwn "50:00:00:00:00:00:00:00"
$bootsanimage | Add-UcsLsbootSanImagePath -Lun 0 -Type "secondary" -Wwn "50:00:00:00:00:00:00:00"
$bp = Add-UcsBootPolicy -Org $organization -Name "BFS-BARE-NONP" -EnforceVnicName yes
$bp | Add-UcsLsBootVirtualMedia -Access "read-only" -Order "1"
$bootstorage = $bp | Add-UcsLsbootStorage -ModifyPresent -Order "2"
$bootsanimage = $bootstorage | Add-UcsLsbootSanImage -Type "primary" -VnicName "BARE-NONP-A"
$bootsanimage | Add-UcsLsbootSanImagePath -Lun 0 -Type "primary" -Wwn "50:00:00:00:00:00:00:00"
$bootsanimage | Add-UcsLsbootSanImagePath -Lun 0 -Type "secondary" -Wwn "50:00:00:00:00:00:00:00"
$bootsanimage = $bootstorage | Add-UcsLsbootSanImage -Type "secondary" -VnicName "BARE-NONP-B"
$bootsanimage | Add-UcsLsbootSanImagePath -Lun 0 -Type "primary" -Wwn "50:00:00:00:00:00:00:00"
$bootsanimage | Add-UcsLsbootSanImagePath -Lun 0 -Type "secondary" -Wwn "50:00:00:00:00:00:00:00"
#endregion
#region vNIC / vHBA Templates
################################################################################################################################
### vNIC/vHBA TEMPLATES ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
################################################################################################################################
#Right now, this vNIC/vHBA creation process is pretty much garbage. It works, but it is among the ugliest parts of this script. I will be changing things around quite a bit later.
# $allowedVLANs is an array, so you can define a list like this: $allowedVLANs = 310, 312, 320, 314, 316, 318
#create vNIC Templates
$vNicTemplate = Add-UcsVnicTemplate -Org $organization -Name "ESX-MGMT-PROD" -Descr "Production ESXi Management" -IdentPoolName "MAC-ESX-PROD-A" -Mtu 1500 -SwitchId A-B -TemplType "updating-template" -QosPolicyName "BE"
$allowedVLANs = 100
$nativeVLAN = 100
foreach ($vlan in $allowedVLANs)
{
if($vlan -eq $nativeVLAN) {
$vlanName = Get-UcsVlan -Id $vlan | select name
Add-UcsVnicInterface -VnicTemplate $vNicTemplate -name $vlanName.name -DefaultNet true
} else {
$vlanName = Get-UcsVlan -Id $vlan | select name
Add-UcsVnicInterface -VnicTemplate $vNicTemplate -name $vlanName.name -DefaultNet false
}
}
$vNicTemplate = Add-UcsVnicTemplate -Org $organization -Name "ESX-MGMT-NONP" -Descr "Non-Prod ESXi Management" -IdentPoolName "MAC-ESX-NONP-A" -Mtu 1500 -SwitchId A-B -TemplType "updating-template" -QosPolicyName "BE"
$allowedVLANs = 100
$nativeVLAN = 100
foreach ($vlan in $allowedVLANs)
{
if($vlan -eq $nativeVLAN) {
$vlanName = Get-UcsVlan -Id $vlan | select name
Add-UcsVnicInterface -VnicTemplate $vNicTemplate -name $vlanName.name -DefaultNet true
} else {
$vlanName = Get-UcsVlan -Id $vlan | select name
Add-UcsVnicInterface -VnicTemplate $vNicTemplate -name $vlanName.name -DefaultNet false
}
}
$vNicTemplate = Add-UcsVnicTemplate -Org $organization -Name "ESX-IPST-PROD-A" -Descr "Production ESXi IP Storage Fabric A" -IdentPoolName "MAC-ESX-PROD-A" -Mtu 9000 -SwitchId A -TemplType "updating-template" -QosPolicyName "Silver"
$allowedVLANs = 120
$nativeVLAN = 120
foreach ($vlan in $allowedVLANs)
{
if($vlan -eq $nativeVLAN) {
$vlanName = Get-UcsVlan -Id $vlan | select name
Add-UcsVnicInterface -VnicTemplate $vNicTemplate -name $vlanName.name -DefaultNet true
} else {
$vlanName = Get-UcsVlan -Id $vlan | select name
Add-UcsVnicInterface -VnicTemplate $vNicTemplate -name $vlanName.name -DefaultNet false
}
}
$vNicTemplate = Add-UcsVnicTemplate -Org $organization -Name "ESX-IPST-NONP-A" -Descr "Non-Prod ESXi IP Storage Fabric A" -IdentPoolName "MAC-ESX-NONP-A" -Mtu 9000 -SwitchId A -TemplType "updating-template" -QosPolicyName "Silver"
$allowedVLANs = 120
$nativeVLAN = 120
foreach ($vlan in $allowedVLANs)
{
if($vlan -eq $nativeVLAN) {
$vlanName = Get-UcsVlan -Id $vlan | select name
Add-UcsVnicInterface -VnicTemplate $vNicTemplate -name $vlanName.name -DefaultNet true
} else {
$vlanName = Get-UcsVlan -Id $vlan | select name
Add-UcsVnicInterface -VnicTemplate $vNicTemplate -name $vlanName.name -DefaultNet false
}
}
$vNicTemplate = Add-UcsVnicTemplate -Org $organization -Name "ESX-IPST-PROD-B" -Descr "Production ESXi IP Storage Fabric B" -IdentPoolName "MAC-ESX-PROD-B" -Mtu 9000 -SwitchId B -TemplType "updating-template" -QosPolicyName "Silver"
$allowedVLANs = 120
$nativeVLAN = 120
foreach ($vlan in $allowedVLANs)
{
if($vlan -eq $nativeVLAN) {
$vlanName = Get-UcsVlan -Id $vlan | select name
Add-UcsVnicInterface -VnicTemplate $vNicTemplate -name $vlanName.name -DefaultNet true
} else {
$vlanName = Get-UcsVlan -Id $vlan | select name
Add-UcsVnicInterface -VnicTemplate $vNicTemplate -name $vlanName.name -DefaultNet false
}
}
$vNicTemplate = Add-UcsVnicTemplate -Org $organization -Name "ESX-IPST-NONP-B" -Descr "Non-Prod ESXi IP Storage Fabric B" -IdentPoolName "MAC-ESX-NONP-B" -Mtu 9000 -SwitchId B -TemplType "updating-template" -QosPolicyName "Silver"
$allowedVLANs = 120
$nativeVLAN = 120
foreach ($vlan in $allowedVLANs)
{
if($vlan -eq $nativeVLAN) {
$vlanName = Get-UcsVlan -Id $vlan | select name
Add-UcsVnicInterface -VnicTemplate $vNicTemplate -name $vlanName.name -DefaultNet true
} else {
$vlanName = Get-UcsVlan -Id $vlan | select name
Add-UcsVnicInterface -VnicTemplate $vNicTemplate -name $vlanName.name -DefaultNet false
}
}
$vNicTemplate = Add-UcsVnicTemplate -Org $organization -Name "BARE-IPST-PROD-A" -Descr "Production Baremetal IP Storage Fabric A" -IdentPoolName "MAC-BARE-PROD-A" -Mtu 9000 -SwitchId A -TemplType "updating-template" -QosPolicyName "Silver"
$allowedVLANs = 120
$nativeVLAN = 120
foreach ($vlan in $allowedVLANs)
{
if($vlan -eq $nativeVLAN) {
$vlanName = Get-UcsVlan -Id $vlan | select name
Add-UcsVnicInterface -VnicTemplate $vNicTemplate -name $vlanName.name -DefaultNet true
} else {
$vlanName = Get-UcsVlan -Id $vlan | select name
Add-UcsVnicInterface -VnicTemplate $vNicTemplate -name $vlanName.name -DefaultNet false
}
}
$vNicTemplate = Add-UcsVnicTemplate -Org $organization -Name "BARE-IPST-NONP-A" -Descr "Non-Prod Baremetal IP Storage Fabric A" -IdentPoolName "MAC-BARE-NONP-A" -Mtu 9000 -SwitchId A -TemplType "updating-template" -QosPolicyName "Silver"
$allowedVLANs = 120
$nativeVLAN = 120
foreach ($vlan in $allowedVLANs)
{
if($vlan -eq $nativeVLAN) {
$vlanName = Get-UcsVlan -Id $vlan | select name
Add-UcsVnicInterface -VnicTemplate $vNicTemplate -name $vlanName.name -DefaultNet true
} else {
$vlanName = Get-UcsVlan -Id $vlan | select name
Add-UcsVnicInterface -VnicTemplate $vNicTemplate -name $vlanName.name -DefaultNet false
}
}
$vNicTemplate = Add-UcsVnicTemplate -Org $organization -Name "BARE-IPST-PROD-B" -Descr "Production Baremetal IP Storage Fabric B" -IdentPoolName "MAC-BARE-PROD-B" -Mtu 9000 -SwitchId B -TemplType "updating-template" -QosPolicyName "Silver"
$allowedVLANs = 120
$nativeVLAN = 120
foreach ($vlan in $allowedVLANs)
{
if($vlan -eq $nativeVLAN) {
$vlanName = Get-UcsVlan -Id $vlan | select name
Add-UcsVnicInterface -VnicTemplate $vNicTemplate -name $vlanName.name -DefaultNet true
} else {
$vlanName = Get-UcsVlan -Id $vlan | select name
Add-UcsVnicInterface -VnicTemplate $vNicTemplate -name $vlanName.name -DefaultNet false
}
}
$vNicTemplate = Add-UcsVnicTemplate -Org $organization -Name "BARE-IPST-NONP-B" -Descr "Non-Prod Baremetal IP Storage Fabric B" -IdentPoolName "MAC-BARE-NONP-B" -Mtu 9000 -SwitchId B -TemplType "updating-template" -QosPolicyName "Silver"
$allowedVLANs = 120
$nativeVLAN = 120
foreach ($vlan in $allowedVLANs)
{
if($vlan -eq $nativeVLAN) {
$vlanName = Get-UcsVlan -Id $vlan | select name
Add-UcsVnicInterface -VnicTemplate $vNicTemplate -name $vlanName.name -DefaultNet true
} else {
$vlanName = Get-UcsVlan -Id $vlan | select name
Add-UcsVnicInterface -VnicTemplate $vNicTemplate -name $vlanName.name -DefaultNet false
}
}
$vNicTemplate = Add-UcsVnicTemplate -Org $organization -Name "ESX-VMTR-PROD-A" -Descr "Production ESXi VM Traffic Fabric A" -IdentPoolName "MAC-ESX-PROD-A" -Mtu 1500 -SwitchId A -TemplType "updating-template" -QosPolicyName "BE"
$allowedVLANs = 210
$nativeVLAN = 0
foreach ($vlan in $allowedVLANs)
{
if($vlan -eq $nativeVLAN) {
$vlanName = Get-UcsVlan -Id $vlan | select name
Add-UcsVnicInterface -VnicTemplate $vNicTemplate -name $vlanName.name -DefaultNet true
} else {
$vlanName = Get-UcsVlan -Id $vlan | select name
Add-UcsVnicInterface -VnicTemplate $vNicTemplate -name $vlanName.name -DefaultNet false
}
}
$vNicTemplate = Add-UcsVnicTemplate -Org $organization -Name "ESX-VMTR-NONP-A" -Descr "Non-Prod ESXi VM Traffic Fabric A" -IdentPoolName "MAC-ESX-NONP-A" -Mtu 1500 -SwitchId A -TemplType "updating-template" -QosPolicyName "BE"
$allowedVLANs = 220
$nativeVLAN = 0
foreach ($vlan in $allowedVLANs)
{
if($vlan -eq $nativeVLAN) {
$vlanName = Get-UcsVlan -Id $vlan | select name
Add-UcsVnicInterface -VnicTemplate $vNicTemplate -name $vlanName.name -DefaultNet true
} else {
$vlanName = Get-UcsVlan -Id $vlan | select name
Add-UcsVnicInterface -VnicTemplate $vNicTemplate -name $vlanName.name -DefaultNet false
}
}
$vNicTemplate = Add-UcsVnicTemplate -Org $organization -Name "ESX-VMTR-PROD-B" -Descr "Production ESXi VM Traffic Fabric B" -IdentPoolName "MAC-ESX-PROD-B" -Mtu 1500 -SwitchId B -TemplType "updating-template" -QosPolicyName "BE"
$allowedVLANs = 210
$nativeVLAN = 0
foreach ($vlan in $allowedVLANs)
{
if($vlan -eq $nativeVLAN) {
$vlanName = Get-UcsVlan -Id $vlan | select name
Add-UcsVnicInterface -VnicTemplate $vNicTemplate -name $vlanName.name -DefaultNet true
} else {
$vlanName = Get-UcsVlan -Id $vlan | select name
Add-UcsVnicInterface -VnicTemplate $vNicTemplate -name $vlanName.name -DefaultNet false
}
}
$vNicTemplate = Add-UcsVnicTemplate -Org $organization -Name "ESX-VMTR-NONP-B" -Descr "Non-Prod ESXi VM Traffic Fabric B" -IdentPoolName "MAC-ESX-NONP-B" -Mtu 1500 -SwitchId B -TemplType "updating-template" -QosPolicyName "BE"
$allowedVLANs = 220
$nativeVLAN = 0
foreach ($vlan in $allowedVLANs)
{
if($vlan -eq $nativeVLAN) {
$vlanName = Get-UcsVlan -Id $vlan | select name
Add-UcsVnicInterface -VnicTemplate $vNicTemplate -name $vlanName.name -DefaultNet true
} else {
$vlanName = Get-UcsVlan -Id $vlan | select name
Add-UcsVnicInterface -VnicTemplate $vNicTemplate -name $vlanName.name -DefaultNet false
}
}
$vNicTemplate = Add-UcsVnicTemplate -Org $organization -Name "ESX-VMOT-PROD" -Descr "Production ESXi vMotion" -IdentPoolName "MAC-ESX-PROD-B" -Mtu 9000 -SwitchId B-A -TemplType "updating-template" -QosPolicyName "Bronze"
$allowedVLANs = 110
$nativeVLAN = 110
foreach ($vlan in $allowedVLANs)
{
if($vlan -eq $nativeVLAN) {
$vlanName = Get-UcsVlan -Id $vlan | select name
Add-UcsVnicInterface -VnicTemplate $vNicTemplate -name $vlanName.name -DefaultNet true
} else {
$vlanName = Get-UcsVlan -Id $vlan | select name
Add-UcsVnicInterface -VnicTemplate $vNicTemplate -name $vlanName.name -DefaultNet false
}
}
$vNicTemplate = Add-UcsVnicTemplate -Org $organization -Name "ESX-VMOT-NONP" -Descr "Non-Prod ESXi vMotion" -IdentPoolName "MAC-ESX-NONP-B" -Mtu 9000 -SwitchId B-A -TemplType "updating-template" -QosPolicyName "Bronze"
$allowedVLANs = 110
$nativeVLAN = 110
foreach ($vlan in $allowedVLANs)
{
if($vlan -eq $nativeVLAN) {
$vlanName = Get-UcsVlan -Id $vlan | select name
Add-UcsVnicInterface -VnicTemplate $vNicTemplate -name $vlanName.name -DefaultNet true
} else {
$vlanName = Get-UcsVlan -Id $vlan | select name
Add-UcsVnicInterface -VnicTemplate $vNicTemplate -name $vlanName.name -DefaultNet false
}
}
$vNicTemplate = Add-UcsVnicTemplate -Org $organization -Name "BARE-PROD-A" -Descr "Production Baremetal Fabric A" -IdentPoolName "MAC-BARE-PROD-A" -Mtu 1500 -SwitchId A -TemplType "updating-template" -QosPolicyName "BE"
$allowedVLANs = 230
$nativeVLAN = 0
foreach ($vlan in $allowedVLANs)
{
if($vlan -eq $nativeVLAN) {
$vlanName = Get-UcsVlan -Id $vlan | select name
Add-UcsVnicInterface -VnicTemplate $vNicTemplate -name $vlanName.name -DefaultNet true
} else {
$vlanName = Get-UcsVlan -Id $vlan | select name
Add-UcsVnicInterface -VnicTemplate $vNicTemplate -name $vlanName.name -DefaultNet false
}
}
$vNicTemplate = Add-UcsVnicTemplate -Org $organization -Name "BARE-NONP-A" -Descr "Non-Prod Baremetal Fabric A" -IdentPoolName "MAC-BARE-NONP-A" -Mtu 1500 -SwitchId A -TemplType "updating-template" -QosPolicyName "BE"
$allowedVLANs = 240
$nativeVLAN = 0
foreach ($vlan in $allowedVLANs)
{
if($vlan -eq $nativeVLAN) {
$vlanName = Get-UcsVlan -Id $vlan | select name
Add-UcsVnicInterface -VnicTemplate $vNicTemplate -name $vlanName.name -DefaultNet true
} else {
$vlanName = Get-UcsVlan -Id $vlan | select name
Add-UcsVnicInterface -VnicTemplate $vNicTemplate -name $vlanName.name -DefaultNet false
}
}
$vNicTemplate = Add-UcsVnicTemplate -Org $organization -Name "BARE-PROD-B" -Descr "Production Baremetal Fabric B" -IdentPoolName "MAC-BARE-PROD-B" -Mtu 1500 -SwitchId A -TemplType "updating-template" -QosPolicyName "BE"
$allowedVLANs = 230
$nativeVLAN = 0
foreach ($vlan in $allowedVLANs)
{
if($vlan -eq $nativeVLAN) {
$vlanName = Get-UcsVlan -Id $vlan | select name
Add-UcsVnicInterface -VnicTemplate $vNicTemplate -name $vlanName.name -DefaultNet true
} else {
$vlanName = Get-UcsVlan -Id $vlan | select name
Add-UcsVnicInterface -VnicTemplate $vNicTemplate -name $vlanName.name -DefaultNet false
}
}
$vNicTemplate = Add-UcsVnicTemplate -Org $organization -Name "BARE-NONP-B" -Descr "Non-Prod Baremetal Fabric B" -IdentPoolName "MAC-BARE-NONP-B" -Mtu 1500 -SwitchId A -TemplType "updating-template" -QosPolicyName "BE"
$allowedVLANs = 240
$nativeVLAN = 0
foreach ($vlan in $allowedVLANs)
{
if($vlan -eq $nativeVLAN) {
$vlanName = Get-UcsVlan -Id $vlan | select name
Add-UcsVnicInterface -VnicTemplate $vNicTemplate -name $vlanName.name -DefaultNet true
} else {
$vlanName = Get-UcsVlan -Id $vlan | select name
Add-UcsVnicInterface -VnicTemplate $vNicTemplate -name $vlanName.name -DefaultNet false
}
}
#create vHBA Templates
$vHbaTemplate = Add-UcsVhbaTemplate -Org $organization -Name "ESX-PROD-A" -Descr "Production ESXi Fabric A" -IdentPoolName "WWPN-ESX-PROD-A" -SwitchId A -TemplType "updating-template"
$vsanName = Get-UcsVsan -Id 2100 | select name
Add-UcsVhbaInterface -VhbaTemplate $vHbaTemplate -name $vsanName.name
$vHbaTemplate = Add-UcsVhbaTemplate -Org $organization -Name "ESX-NONP-A" -Descr "Non-Prod ESXi Fabric A" -IdentPoolName "WWPN-ESX-NONP-A" -SwitchId A -TemplType "updating-template"
$vsanName = Get-UcsVsan -Id 2110 | select name
Add-UcsVhbaInterface -VhbaTemplate $vHbaTemplate -name $vsanName.name
$vHbaTemplate = Add-UcsVhbaTemplate -Org $organization -Name "ESX-PROD-B" -Descr "Production ESXi Fabric B" -IdentPoolName "WWPN-ESX-PROD-B" -SwitchId A -TemplType "updating-template"
$vsanName = Get-UcsVsan -Id 2200 | select name
Add-UcsVhbaInterface -VhbaTemplate $vHbaTemplate -name $vsanName.name
$vHbaTemplate = Add-UcsVhbaTemplate -Org $organization -Name "ESX-NONP-B" -Descr "Non-Prod ESXi Fabric B" -IdentPoolName "WWPN-ESX-NONP-B" -SwitchId A -TemplType "updating-template"
$vsanName = Get-UcsVsan -Id 2210 | select name
Add-UcsVhbaInterface -VhbaTemplate $vHbaTemplate -name $vsanName.name
$vHbaTemplate = Add-UcsVhbaTemplate -Org $organization -Name "BARE-PROD-A" -Descr "Production Baremetal Fabric A" -IdentPoolName "WWPN-BARE-PROD-A" -SwitchId A -TemplType "updating-template"
$vsanName = Get-UcsVsan -Id 2100 | select name
Add-UcsVhbaInterface -VhbaTemplate $vHbaTemplate -name $vsanName.name
$vHbaTemplate = Add-UcsVhbaTemplate -Org $organization -Name "BARE-NONP-A" -Descr "Non-Prod Baremetal Fabric A" -IdentPoolName "WWPN-BARE-NONP-A" -SwitchId A -TemplType "updating-template"
$vsanName = Get-UcsVsan -Id 2110 | select name
Add-UcsVhbaInterface -VhbaTemplate $vHbaTemplate -name $vsanName.name
$vHbaTemplate = Add-UcsVhbaTemplate -Org $organization -Name "BARE-PROD-B" -Descr "Production Baremetal Fabric B" -IdentPoolName "WWPN-BARE-PROD-B" -SwitchId A -TemplType "updating-template"
$vsanName = Get-UcsVsan -Id 2200 | select name
Add-UcsVhbaInterface -VhbaTemplate $vHbaTemplate -name $vsanName.name
$vHbaTemplate = Add-UcsVhbaTemplate -Org $organization -Name "BARE-NONP-B" -Descr "Non-Prod Baremetal Fabric B" -IdentPoolName "WWPN-BARE-NONP-B" -SwitchId A -TemplType "updating-template"
$vsanName = Get-UcsVsan -Id 2210 | select name
Add-UcsVhbaInterface -VhbaTemplate $vHbaTemplate -name $vsanName.name
#endregion
#region Service Profiles and Service Profile Templates
################################################################################################################################
### SERVICE PROFILES AND SERVICE PROFILE TEMPLATES ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
################################################################################################################################
#Create SPT basics
$SPName = "BARE-SQL-PROD"
$SPT = Add-UcsServiceProfile `
-Org $organization `
-Name $SPName `
-Descr "Baremetal SQL - Production" `
-ExtIPPoolName "ext-mgmt" `
-ExtIPState "pooled" `
-HostFwPolicyName "HOSTFW-PLCY" `
-IdentPoolName "UUID-BARE-PROD" `
-MaintPolicyName "MAINT-USER-ACK" `
-Type "updating-template"
#Assign SPT to pre-existing server pool
$SPT | Add-UcsServerPoolAssignment -Name "B200-512-POOL" -RestrictMigration "no"
#Assign the appropriate WWNN pool to this SPT
$SPT | Add-UcsVnicFcNode -IdentPoolName "WWNN-BARE-PROD"
#Create a list of vNICs to Assign to this SPT and loop through and assign them
$vNicArray = `
"BARE-PROD-A", `
"BARE-PROD-B", `
"BARE-IPST-PROD-A", `
"BARE-IPST-PROD-B"
foreach ($vNicInstance in $vNicArray) {
Get-UcsServiceProfile -Name $SPName | Add-UcsVnic -NwTemplName $vNicInstance -Name $vNicInstance -AdaptorProfileName "Windows"
}
#Create a list of vHBAs to Assign to this SPT and loop through and assign them
$vHbaArray = `
"BARE-PROD-A", `
"BARE-PROD-B"
foreach ($vHbaInstance in $vHbaArray) {
Get-UcsServiceProfile -Name $SPName | Add-UcsVhba -NwTemplName $vHbaInstance -Name $vHbaInstance -AdaptorProfileName "Windows"
}
#Create SPT basics
$SPName = "BARE-SQL-NONP"
$SPT = Add-UcsServiceProfile `
-Org $organization `
-Name $SPName `
-Descr "Baremetal SQL - Non-Prod" `
-ExtIPPoolName "ext-mgmt" `
-ExtIPState "pooled" `
-HostFwPolicyName "HOSTFW-PLCY" `
-IdentPoolName "UUID-BARE-NONP" `
-MaintPolicyName "MAINT-USER-ACK" `
-Type "updating-template"
#Assign SPT to pre-existing server pool
$SPT | Add-UcsServerPoolAssignment -Name "B230-POOL" -RestrictMigration "no"
#Assign the appropriate WWNN pool to this SPT
$SPT | Add-UcsVnicFcNode -IdentPoolName "WWNN-BARE-NONP"
#Create a list of vNICs to Assign to this SPT and loop through and assign them
$vNicArray = `
"BARE-NONP-A", `
"BARE-NONP-B", `
"BARE-IPST-NONP-A", `
"BARE-IPST-NONP-B"
foreach ($vNicInstance in $vNicArray) {
Get-UcsServiceProfile -Name $SPName | Add-UcsVnic -NwTemplName $vNicInstance -Name $vNicInstance -AdaptorProfileName "Windows"
}
#Create a list of vHBAs to Assign to this SPT and loop through and assign them
$vHbaArray = `
"BARE-NONP-A", `
"BARE-NONP-B"
foreach ($vHbaInstance in $vHbaArray) {
Get-UcsServiceProfile -Name $SPName | Add-UcsVhba -NwTemplName $vHbaInstance -Name $vHbaInstance -AdaptorProfileName "Windows"
}
#Create SPT basics
$SPName = "SPT-ESX-PROD"
$SPT = Add-UcsServiceProfile `
-Org $organization `
-Name $SPName `
-Descr "ESXi - Production" `
-ExtIPPoolName "ext-mgmt" `
-ExtIPState "pooled" `
-HostFwPolicyName "HOSTFW-PLCY" `
-IdentPoolName "UUID-ESX-PROD" `
-MaintPolicyName "MAINT-USER-ACK" `
-Type "updating-template"
#Assign SPT to pre-existing server pool
$SPT | Add-UcsServerPoolAssignment -Name "B200-256-POOL" -RestrictMigration "no"
#Assign the appropriate WWNN pool to this SPT
$SPT | Add-UcsVnicFcNode -IdentPoolName "WWNN-ESX-PROD"
#Create a list of vNICs to Assign to this SPT and loop through and assign them
$vNicArray = `
"ESX-MGMT-PROD", `
"ESX-IPST-PROD-A", `
"ESX-IPST-PROD-B", `
"ESX-VMTR-PROD-A", `
"ESX-VMTR-PROD-B", `
"ESX-VMOT-PROD"
foreach ($vNicInstance in $vNicArray) {
Get-UcsServiceProfile -Name $SPName | Add-UcsVnic -NwTemplName $vNicInstance -Name $vNicInstance -AdaptorProfileName "VMWare"
}
#Create a list of vHBAs to Assign to this SPT and loop through and assign them
$vHbaArray = `
"ESX-PROD-A", `
"ESX-PROD-B"
foreach ($vHbaInstance in $vHbaArray) {
Get-UcsServiceProfile -Name $SPName | Add-UcsVhba -NwTemplName $vHbaInstance -Name $vHbaInstance -AdaptorProfileName "VMWare"
}
#Create SPT basics
$SPName = "SPT-ESX-NONP"
$SPT = Add-UcsServiceProfile `
-Org $organization `
-Name $SPName `
-Descr "ESXi - Non-Prod" `
-ExtIPPoolName "ext-mgmt" `
-ExtIPState "pooled" `
-HostFwPolicyName "HOSTFW-PLCY" `
-IdentPoolName "UUID-ESX-NONP" `
-MaintPolicyName "MAINT-USER-ACK" `
-Type "updating-template"
#Assign SPT to pre-existing server pool
$SPT | Add-UcsServerPoolAssignment -Name "B200-256-POOL" -RestrictMigration "no"
#Assign the appropriate WWNN pool to this SPT
$SPT | Add-UcsVnicFcNode -IdentPoolName "WWNN-ESX-NONP"
#Create a list of vNICs to Assign to this SPT and loop through and assign them
$vNicArray = `
"ESX-MGMT-NONP", `
"ESX-IPST-NONP-A", `
"ESX-IPST-NONP-B", `
"ESX-VMTR-NONP-A", `
"ESX-VMTR-NONP-B", `
"ESX-VMOT-NONP"
foreach ($vNicInstance in $vNicArray) {
Get-UcsServiceProfile -Name $SPName | Add-UcsVnic -NwTemplName $vNicInstance -Name $vNicInstance -AdaptorProfileName "VMWare"
}
#Create a list of vHBAs to Assign to this SPT and loop through and assign them
$vHbaArray = `
"ESX-NONP-A", `
"ESX-NONP-B"
foreach ($vHbaInstance in $vHbaArray) {
Get-UcsServiceProfile -Name $SPName | Add-UcsVhba -NwTemplName $vHbaInstance -Name $vHbaInstance -AdaptorProfileName "VMWare"
}
#Generate 2 Service Profiles from each template - THIS IS TERRIBLE AND UGLY AND YOU NEED TO MAKE THIS NOT SUCK
$SPTArray = Get-UcsServiceProfile -Type updating-template | select name
foreach ($SPTname in $SPTArray) {
$sptNameLength = $SPTname.name.length
$spName = "SP_" + $SPTname.name.substring(4, $sptNameLength - 4) + "01"
Add-UcsServiceProfile -Org $organization -SrcTemplName $SPTname.name -Name $spName
$spName = "SP_" + $SPTname.name.substring(4, $sptNameLength - 4) + "02"
Add-UcsServiceProfile -Org $organization -SrcTemplName $SPTname.name -Name $spName
}
#endregion
Write-Host "Script completed in: " $Elapsed.Elapsed