The comparison should be with the apparent power, otherwise, the inverter will provide to the system more power that is generated in the PV module.
For example, for pf=0.9 the module is providing 185W and 90VAr.
The text was updated successfully, but these errors were encountered:
The comparison should be with the apparent power, otherwise, the inverter will provide to the system more power that is generated in the PV module.
For example, for pf=0.9 the module is providing 185W and 90VAr.