Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

Ventilationmode from plugin Duco ventilation remote stays on automatic as feedback #120

Open
Jozziej opened this issue Nov 6, 2022 · 8 comments

Comments

@Jozziej
Copy link

Jozziej commented Nov 6, 2022

Ventilationmode from plugin Duco ventilation remote stays on automatic as feedback, this worked before as I display the ventilation mode in Home Assistant

Schermafbeelding 2022-11-06 110357
Schermafbeelding 2022-11-06 110645

Firmware 24 October is used, rollback to 4 July firmware doesn't fix it either.

Loose plugin Duco_Ventilationmode does work, sadly that it requires to have another plugin actively sending to the controller.

@arnemauer
Copy link
Owner

Make us happy with some logs :)

@Jozziej
Copy link
Author

Jozziej commented Nov 7, 2022

Log ```

87581606: [P154] DUCO Ext. CO2 Sensor: start read, eventid:1
87581606: [P154] DUCO Ext. CO2 Sensor: Read external CO2 sensor.
87581607: [P154] DUCO Ext. CO2 Sensor: Start read external sensor. NodeAddress: 3. Type: CO2
87581948: [P154] DUCO Ext. CO2 Sensor: Command confirmed by ducobox
87581959: [P154] DUCO Ext. CO2 Sensor: Send command successfull!
87583263: [P154] DUCO Ext. CO2 Sensor: Serial reading timeout
87583264: [P154] DUCO Ext. CO2 Sensor: Stop reading from serial
87585189: [P150] RF GW: UPDATE by PLUGIN_READ
87585486: [P151] DUCO SER GW: Start readNetworkList
87585694: [P151] DUCO SER GW: Received correct response on network
87585707: [P151] DUCO SER GW: Send command successfull!
87585729: [P151] DUCO SER GW: Ducobox row found!
87585730: [P151] DUCO SER GW: New Ventilationmode value: 11
87585731: [P151] DUCO SER GW: New Countdown value: 0
87585731: [P151] DUCO SER GW: New Ventilation_Percentage value: 20
87585731: [P151] DUCO SER GW: New Current_Fan_Value value: 7
87585809: [P151] DUCO SER GW: End of message received.
87585810: [P151] DUCO SER GW: Stop reading from serial
87588819: WD : Uptime 1460 ConnectFailures 0 FreeMem 18416 WiFiStatus 3 ESPeasy internal wifi status: Conn. IP Init
87591483: [P151] DUCO SER GW: Start readNetworkList
87591644: [P151] DUCO SER GW: Received correct response on network
87591659: [P151] DUCO SER GW: Send command successfull!
87591684: [P151] DUCO SER GW: Ducobox row found!
87591685: [P151] DUCO SER GW: New Ventilationmode value: 11
87591685: [P151] DUCO SER GW: New Countdown value: 0
87591686: [P151] DUCO SER GW: New Ventilation_Percentage value: 20
87591686: [P151] DUCO SER GW: New Current_Fan_Value value: 7
87591764: [P151] DUCO SER GW: End of message received.
87591764: [P151] DUCO SER GW: Stop reading from serial
87593608: [P154] DUCO Ext. CO2 Sensor: start read, eventid:1
87593608: [P154] DUCO Ext. CO2 Sensor: Read external CO2 sensor.
87593608: [P154] DUCO Ext. CO2 Sensor: Start read external sensor. NodeAddress: 3. Type: CO2
87593950: [P154] DUCO Ext. CO2 Sensor: Command confirmed by ducobox
87593963: [P154] DUCO Ext. CO2 Sensor: Send command successfull!
87594709: [P154] DUCO Ext. CO2 Sensor: CO2 PPM: 414 = 414 PPM
87594716: [P154] DUCO Ext. CO2 Sensor: End of message received.
87594716: [P154] DUCO Ext. CO2 Sensor: Stop reading from serial
87597189: [P150] RF GW: UPDATE by PLUGIN_READ
87597485: [P151] DUCO SER GW: Start readNetworkList
87597648: [P151] DUCO SER GW: Received correct response on network
87597662: [P151] DUCO SER GW: Send command successfull!
87597736: [P151] DUCO SER GW: Ducobox row found!
87597736: [P151] DUCO SER GW: Status value not found.
87597737: [P151] DUCO SER GW: New Countdown value: 0
87597737: [P151] DUCO SER GW: Numeric value not found.
87597737: [P151] DUCO SER GW: Numeric value not found.
87597767: [P151] DUCO SER GW: End of message received.
87597768: [P151] DUCO SER GW: Stop reading from serial
87603483: [P151] DUCO SER GW: Start readNetworkList
87603629: [P151] DUCO SER GW: Received correct response on network
87603646: [P151] DUCO SER GW: Send command successfull!
87603669: [P151] DUCO SER GW: Ducobox row found!
87603670: [P151] DUCO SER GW: New Ventilationmode value: 11
87603670: [P151] DUCO SER GW: New Countdown value: 0
87603671: [P151] DUCO SER GW: New Ventilation_Percentage value: 20
87603671: [P151] DUCO SER GW: New Current_Fan_Value value: 7
87603754: [P151] DUCO SER GW: End of message received.
87603755: [P151] DUCO SER GW: Stop reading from serial
87605606: [P154] DUCO Ext. CO2 Sensor: start read, eventid:1
87605606: [P154] DUCO Ext. CO2 Sensor: Read external CO2 sensor.
87605607: [P154] DUCO Ext. CO2 Sensor: Start read external sensor. NodeAddress: 3. Type: CO2
87606002: [P154] DUCO Ext. CO2 Sensor: Command confirmed by ducobox
87606016: [P154] DUCO Ext. CO2 Sensor: Send command successfull!
87606043: [P154] DUCO Ext. CO2 Sensor: CO2 PPM: 414 = 414 PPM
87606049: [P154] DUCO Ext. CO2 Sensor: End of message received.
87606049: [P154] DUCO Ext. CO2 Sensor: Stop reading from serial
87607144: HTTP: VENTMODE,LOW
87607146: Command: VENTMODE
87607147: [P150] RF GW: Sent command 'VENTMODE low' to DUCO unit
87607155: [P150] RF GW: 0 - requestVentilationMode();
87607155: [P150] RF GW: 1 - sendVentilationModeMessage();
87607155: [P150] RF GW: 2 - Start waiting for ack...
87607466: [P150] RF GW: 0 - CheckforAck: check if 300ms is verstreken
87607467: [P150] RF GW: 1 - CheckforAck: still waiting for ACK. Sending message again...
87607467: [P150] RF GW: 2 - Start waiting for ack...
87607786: [P150] RF GW: 0 - CheckforAck: check if 300ms is verstreken
87607787: [P150] RF GW: 1 - CheckforAck: still waiting for ACK. Sending message again...
87607787: [P150] RF GW: 2 - Start waiting for ack...
87608106: [P150] RF GW: 0 - CheckforAck: check if 300ms is verstreken
87608106: [P150] RF GW: 1 - CheckforAck: still waiting for ACK. Sending message again...
87608107: [P150] RF GW: 2 - Start waiting for ack...
87608420: [P150] RF GW: 0 - CheckforAck: check if 300ms is verstreken
87608420: [P150] RF GW: 1 - CheckforAck: no ack received, cancel retrying.
87608694: [P150] RF GW: RX FIFO OVERFLOW -> idle, flush RX FIFO and switch to RX state.
87608905: HTTP: VENTMODE,LOW
87608907: Command: VENTMODE
87608908: [P150] RF GW: Sent command 'VENTMODE low' to DUCO unit
87608916: [P150] RF GW: 0 - requestVentilationMode();
87608916: [P150] RF GW: 1 - sendVentilationModeMessage();
87608916: [P150] RF GW: 2 - Start waiting for ack...
87609189: [P150] RF GW: UPDATE by PLUGIN_READ
87609242: [P150] RF GW: 0 - CheckforAck: check if 300ms is verstreken
87609242: [P150] RF GW: 1 - CheckforAck: still waiting for ACK. Sending message again...
87609242: [P150] RF GW: 2 - Start waiting for ack...
87609484: [P151] DUCO SER GW: Start readNetworkList
87609562: [P150] RF GW: 0 - CheckforAck: check if 300ms is verstreken
87609562: [P150] RF GW: 1 - CheckforAck: still waiting for ACK. Sending message again...
87609562: [P150] RF GW: 2 - Start waiting for ack...
87609641: [P151] DUCO SER GW: Received correct response on network
87609654: [P151] DUCO SER GW: Send command successfull!
87609681: [P151] DUCO SER GW: Ducobox row found!
87609682: [P151] DUCO SER GW: New Ventilationmode value: 1
87609682: [P151] DUCO SER GW: New Countdown value: 1800
87609683: [P151] DUCO SER GW: New Ventilation_Percentage value: 20
87609683: [P151] DUCO SER GW: New Current_Fan_Value value: 7
87609767: [P151] DUCO SER GW: End of message received.
87609767: [P151] DUCO SER GW: Stop reading from serial
87609881: [P150] RF GW: 0 - CheckforAck: check if 300ms is verstreken
87609882: [P150] RF GW: 1 - CheckforAck: still waiting for ACK. Sending message again...
87609882: [P150] RF GW: 2 - Start waiting for ack...
87610184: [P150] RF GW: 0 - CheckforAck: check if 300ms is verstreken
87610184: [P150] RF GW: 1 - CheckforAck: no ack received, cancel retrying.
87610270: [P151] DUCO SER GW: New value for Ventilationmode
87614366: HTTP: VENTMODE,MIDDLE
87614368: Command: VENTMODE
87614369: [P150] RF GW: Sent command 'VENTMODE middle' to DUCO unit
87614377: [P150] RF GW: 0 - requestVentilationMode();
87614377: [P150] RF GW: 1 - sendVentilationModeMessage();
87614377: [P150] RF GW: 2 - Start waiting for ack...
87614702: [P150] RF GW: 0 - CheckforAck: check if 300ms is verstreken
87614703: [P150] RF GW: 1 - CheckforAck: still waiting for ACK. Sending message again...
87614703: [P150] RF GW: 2 - Start waiting for ack...
87615022: [P150] RF GW: 0 - CheckforAck: check if 300ms is verstreken
87615022: [P150] RF GW: 1 - CheckforAck: still waiting for ACK. Sending message again...
87615023: [P150] RF GW: 2 - Start waiting for ack...
87615343: [P150] RF GW: 0 - CheckforAck: check if 300ms is verstreken
87615343: [P150] RF GW: 1 - CheckforAck: still waiting for ACK. Sending message again...
87615343: [P150] RF GW: 2 - Start waiting for ack...
87615482: [P151] DUCO SER GW: Start readNetworkList
87615676: [P150] RF GW: 0 - CheckforAck: check if 300ms is verstreken
87615676: [P150] RF GW: 1 - CheckforAck: no ack received, cancel retrying.
87615703: [P151] DUCO SER GW: Received correct response on network
87615735: HTTP: VENTMODE,MIDDLE
87615739: Command: VENTMODE
87615740: [P150] RF GW: Sent command 'VENTMODE middle' to DUCO unit
87615747: [P150] RF GW: 0 - requestVentilationMode();
87615748: [P150] RF GW: 1 - sendVentilationModeMessage();
87615748: [P150] RF GW: 2 - Start waiting for ack...
87615831: [P151] DUCO SER GW: Send command successfull!
87615836: [P151] DUCO SER GW: End of message received.
87615836: [P151] DUCO SER GW: Stop reading from serial
87616057: [P150] RF GW: 0 - CheckforAck: check if 300ms is verstreken
87616057: [P150] RF GW: 1 - CheckforAck: still waiting for ACK. Sending message again...
87616058: [P150] RF GW: 2 - Start waiting for ack...
87616380: [P150] RF GW: 0 - CheckforAck: check if 300ms is verstreken
87616380: [P150] RF GW: 1 - CheckforAck: still waiting for ACK. Sending message again...
87616380: [P150] RF GW: 2 - Start waiting for ack...
87616690: [P150] RF GW: 0 - CheckforAck: check if 300ms is verstreken
87616691: [P150] RF GW: 1 - CheckforAck: still waiting for ACK. Sending message again...
87616691: [P150] RF GW: 2 - Start waiting for ack...
87617004: [P150] RF GW: 0 - CheckforAck: check if 300ms is verstreken
87617004: [P150] RF GW: 1 - CheckforAck: no ack received, cancel retrying.
87617607: [P154] DUCO Ext. CO2 Sensor: start read, eventid:1
87617607: [P154] DUCO Ext. CO2 Sensor: Read external CO2 sensor.
87617607: [P154] DUCO Ext. CO2 Sensor: Start read external sensor. NodeAddress: 3. Type: CO2
87617996: [P154] DUCO Ext. CO2 Sensor: Command confirmed by ducobox
87618008: [P154] DUCO Ext. CO2 Sensor: Send command successfull!
87618820: WD : Uptime 1460 ConnectFailures 0 FreeMem 18560 WiFiStatus 3 ESPeasy internal wifi status: Conn. IP Init
87619263: [P154] DUCO Ext. CO2 Sensor: Serial reading timeout
87619263: [P154] DUCO Ext. CO2 Sensor: Stop reading from serial
87621189: [P150] RF GW: UPDATE by PLUGIN_READ
87621485: [P151] DUCO SER GW: Start readNetworkList
87621641: [P151] DUCO SER GW: Received correct response on network
87621652: [P151] DUCO SER GW: Send command successfull!
87621681: [P151] DUCO SER GW: Ducobox row found!
87621682: [P151] DUCO SER GW: New Ventilationmode value: 1
87621682: [P151] DUCO SER GW: New Countdown value: 1800
87621682: [P151] DUCO SER GW: New Ventilation_Percentage value: 20
87621683: [P151] DUCO SER GW: New Current_Fan_Value value: 7
87621761: [P151] DUCO SER GW: End of message received.
87621761: [P151] DUCO SER GW: Stop reading from serial
87627483: [P151] DUCO SER GW: Start readNetworkList
87627649: [P151] DUCO SER GW: Received correct response on network
87627659: [P151] DUCO SER GW: Send command successfull!
87627690: [P151] DUCO SER GW: Ducobox row found!
87627691: [P151] DUCO SER GW: New Ventilationmode value: 1
87627691: [P151] DUCO SER GW: New Countdown value: 1795
87627691: [P151] DUCO SER GW: New Ventilation_Percentage value: 20
87627692: [P151] DUCO SER GW: New Current_Fan_Value value: 7
87627771: [P151] DUCO SER GW: End of message received.
87627771: [P151] DUCO SER GW: Stop reading from serial
87627819: [P150] RF GW: 87627801 - 87627819 = 18
87627820: [P150] RF GW: rxBYTES: 10 (hex) 16 (dec); getMarcState 0D
87627821: [P150] RF GW: 0 - Ignore message, not our networkID.
87629606: [P154] DUCO Ext. CO2 Sensor: start read, eventid:1
87629606: [P154] DUCO Ext. CO2 Sensor: Read external CO2 sensor.
87629606: [P154] DUCO Ext. CO2 Sensor: Start read external sensor. NodeAddress: 3. Type: CO2
87629950: [P154] DUCO Ext. CO2 Sensor: Command confirmed by ducobox
87629962: [P154] DUCO Ext. CO2 Sensor: Send command successfull!
87631234: [P154] DUCO Ext. CO2 Sensor: CO2 PPM: 414 = 414 PPM
87631241: [P154] DUCO Ext. CO2 Sensor: End of message received.
87631241: [P154] DUCO Ext. CO2 Sensor: Stop reading from serial
87633189: [P150] RF GW: UPDATE by PLUGIN_READ
87633485: [P151] DUCO SER GW: Start readNetworkList
87633641: [P151] DUCO SER GW: Received correct response on network
87633654: [P151] DUCO SER GW: Send command successfull!
87633681: [P151] DUCO SER GW: Ducobox row found!
87633682: [P151] DUCO SER GW: New Ventilationmode value: 2
87633682: [P151] DUCO SER GW: New Countdown value: 1795
87633682: [P151] DUCO SER GW: New Ventilation_Percentage value: 40
87633683: [P151] DUCO SER GW: New Current_Fan_Value value: 18
87633762: [P151] DUCO SER GW: End of message received.
87633762: [P151] DUCO SER GW: Stop reading from serial
87634269: [P151] DUCO SER GW: New value for Ventilationmode
87634454: [P150] RF GW: 87634444 - 87634454 = 10
87634455: [P150] RF GW: rxBYTES: 14 (hex) 20 (dec); getMarcState 0D
87638495: [P150] RF GW: 87638492 - 87638494 = 2
87638495: [P150] RF GW: rxBYTES: 0C (hex) 12 (dec); getMarcState 0D
87639525: [P151] DUCO SER GW: Start readNetworkList
87639691: [P151] DUCO SER GW: Received correct response on network
87639702: [P151] DUCO SER GW: Send command successfull!
87639731: [P151] DUCO SER GW: Ducobox row found!
87639732: [P151] DUCO SER GW: New Ventilationmode value: 2
87639732: [P151] DUCO SER GW: New Countdown value: 1790
87639732: [P151] DUCO SER GW: New Ventilation_Percentage value: 40
87639733: [P151] DUCO SER GW: New Current_Fan_Value value: 25
87639811: [P151] DUCO SER GW: End of message received.
87639811: [P151] DUCO SER GW: Stop reading from serial
87641606: [P154] DUCO Ext. CO2 Sensor: start read, eventid:1
87641606: [P154] DUCO Ext. CO2 Sensor: Read external CO2 sensor.
87641607: [P154] DUCO Ext. CO2 Sensor: Start read external sensor. NodeAddress: 3. Type: CO2
87641985: [P154] DUCO Ext. CO2 Sensor: Command confirmed by ducobox
87641999: [P150] RF GW: 87641997 - 87641998 = 1
87641999: [P150] RF GW: rxBYTES: 0C (hex) 12 (dec); getMarcState 0D
87642000: [P154] DUCO Ext. CO2 Sensor: Send command successfull!
87642026: [P154] DUCO Ext. CO2 Sensor: CO2 PPM: 414 = 414 PPM
87642032: [P154] DUCO Ext. CO2 Sensor: End of message received.
87642033: [P154] DUCO Ext. CO2 Sensor: Stop reading from serial
87645189: [P150] RF GW: UPDATE by PLUGIN_READ
87645484: [P151] DUCO SER GW: Start readNetworkList
87645640: [P151] DUCO SER GW: Received correct response on network
87645655: [P151] DUCO SER GW: Send command successfull!
87645680: [P151] DUCO SER GW: Ducobox row found!
87645681: [P151] DUCO SER GW: New Ventilationmode value: 2
87645681: [P151] DUCO SER GW: New Countdown value: 1785
87645681: [P151] DUCO SER GW: New Ventilation_Percentage value: 40
87645682: [P151] DUCO SER GW: New Current_Fan_Value value: 26
87645760: [P151] DUCO SER GW: End of message received.
87645760: [P151] DUCO SER GW: Stop reading from serial
87648819: WD : Uptime 1461 ConnectFailures 0 FreeMem 18528 WiFiStatus 3 ESPeasy internal wifi status: Conn. IP Init
87651483: [P151] DUCO SER GW: Start readNetworkList
87651635: [P151] DUCO SER GW: Received correct response on network
87651647: [P151] DUCO SER GW: Send command successfull!
87651675: [P151] DUCO SER GW: Ducobox row found!
87651676: [P151] DUCO SER GW: New Ventilationmode value: 2
87651676: [P151] DUCO SER GW: New Countdown value: 1780
87651676: [P151] DUCO SER GW: New Ventilation_Percentage value: 40
87651677: [P151] DUCO SER GW: New Current_Fan_Value value: 25
87651755: [P151] DUCO SER GW: End of message received.
87651755: [P151] DUCO SER GW: Stop reading from serial

</details>

@arnemauer
Copy link
Owner

The RF-plugin doesn't receive an answer from the Ducobox. If you change the ventilation mode by pressing the blue buttons in Espeasy is the ducobox responding/changing ventilation speed?

@Jozziej
Copy link
Author

Jozziej commented Nov 17, 2022

Here is a new set of logs, went from High to Medium to Low

Log ```

311462845: [P150] RF GW: 0 - CheckforAck: check if 300ms is verstreken
311462845: [P150] RF GW: 1 - CheckforAck: still waiting for ACK. Sending message again...
311462846: [P150] RF GW: 2 - Start waiting for ack...
311463159: [P150] RF GW: 0 - CheckforAck: check if 300ms is verstreken
311463159: [P150] RF GW: 1 - CheckforAck: no ack received, cancel retrying.
311472802: [P150] RF GW: UPDATE by PLUGIN_READ
311472840: [P154] DUCO Ext. CO2 Sensor: start read, eventid:1
311472840: [P154] DUCO Ext. CO2 Sensor: Read external CO2 sensor.
311472840: [P154] DUCO Ext. CO2 Sensor: Start read external sensor. NodeAddress: 3. Type: CO2
311472987: [P151] DUCO SER GW: Serial port in use, set flag to read data later.
311473171: [P154] DUCO Ext. CO2 Sensor: Command confirmed by ducobox
311473184: [P154] DUCO Ext. CO2 Sensor: Send command successfull!
311474734: [P154] DUCO Ext. CO2 Sensor: Serial reading timeout
311474734: [P154] DUCO Ext. CO2 Sensor: Stop reading from serial
311474735: [P151] DUCO SER GW: Start readNetworkList
311474908: [P151] DUCO SER GW: Send command successfull!
311475322: [P151] DUCO SER GW: Received invalid response on network
311475322: [P151] DUCO SER GW: Stop reading from serial
311475323: [P151] DUCO SER GW: End of message received.
311475323: [P151] DUCO SER GW: Stop reading from serial
311478986: [P151] DUCO SER GW: Start readNetworkList
311479134: [P151] DUCO SER GW: Received correct response on network
311479138: [P151] DUCO SER GW: End of message received.
311479138: [P151] DUCO SER GW: Stop reading from serial
311480728: HTTP: VENTMODE,MIDDLE
311480729: Command: VENTMODE
311480731: [P150] RF GW: Sent command 'VENTMODE middle' to DUCO unit
311480739: [P150] RF GW: 0 - requestVentilationMode();
311480739: [P150] RF GW: 1 - sendVentilationModeMessage();
311480739: [P150] RF GW: 2 - Start waiting for ack...
311481053: [P150] RF GW: 0 - CheckforAck: check if 300ms is verstreken
311481053: [P150] RF GW: 1 - CheckforAck: still waiting for ACK. Sending message again...
311481054: [P150] RF GW: 2 - Start waiting for ack...
311481372: [P150] RF GW: 0 - CheckforAck: check if 300ms is verstreken
311481372: [P150] RF GW: 1 - CheckforAck: still waiting for ACK. Sending message again...
311481373: [P150] RF GW: 2 - Start waiting for ack...
311481692: [P150] RF GW: 0 - CheckforAck: check if 300ms is verstreken
311481692: [P150] RF GW: 1 - CheckforAck: still waiting for ACK. Sending message again...
311481693: [P150] RF GW: 2 - Start waiting for ack...
311482046: [P150] RF GW: 0 - CheckforAck: check if 300ms is verstreken
311482046: [P150] RF GW: 1 - CheckforAck: no ack received, cancel retrying.
311484802: [P150] RF GW: UPDATE by PLUGIN_READ
311484840: [P154] DUCO Ext. CO2 Sensor: start read, eventid:1
311484840: [P154] DUCO Ext. CO2 Sensor: Read external CO2 sensor.
311484840: [P154] DUCO Ext. CO2 Sensor: Start read external sensor. NodeAddress: 3. Type: CO2
311484988: [P151] DUCO SER GW: Serial port in use, set flag to read data later.
311485247: [P154] DUCO Ext. CO2 Sensor: Send command successfull!
311485294: [P154] DUCO Ext. CO2 Sensor: Command confirmed by ducobox
311486268: [P154] DUCO Ext. CO2 Sensor: CO2 PPM: 555 = 555 PPM
311486278: [P154] DUCO Ext. CO2 Sensor: End of message received.
311486278: [P154] DUCO Ext. CO2 Sensor: Stop reading from serial
311486734: [P151] DUCO SER GW: Start readNetworkList
311486882: [P151] DUCO SER GW: Received correct response on network
311486887: [P151] DUCO SER GW: End of message received.
311486887: [P151] DUCO SER GW: Stop reading from serial
311491141: [P150] RF GW: 2 - Start waiting for ack...
311491151: [P151] DUCO SER GW: Received correct response on network
311491154: [P151] DUCO SER GW: Send command successfull!
311491191: [P151] DUCO SER GW: Ducobox row found!
311491192: [P151] DUCO SER GW: New Ventilationmode value: 2
311491192: [P151] DUCO SER GW: New Countdown value: 1795
311491193: [P151] DUCO SER GW: New Ventilation_Percentage value: 40
311491193: [P151] DUCO SER GW: New Current_Fan_Value value: 25
311491276: [P151] DUCO SER GW: End of message received.
311491276: [P151] DUCO SER GW: Stop reading from serial
311491460: [P150] RF GW: 0 - CheckforAck: check if 300ms is verstreken
311491461: [P150] RF GW: 1 - CheckforAck: still waiting for ACK. Sending message again...
311491461: [P150] RF GW: 2 - Start waiting for ack...
311491774: [P150] RF GW: 0 - CheckforAck: check if 300ms is verstreken
311491774: [P150] RF GW: 1 - CheckforAck: no ack received, cancel retrying.
311492056: WD : Uptime 5192 ConnectFailures 0 FreeMem 18328 WiFiStatus 3 ESPeasy internal wifi status: Conn. IP Init
311496802: [P150] RF GW: UPDATE by PLUGIN_READ
311496840: [P154] DUCO Ext. CO2 Sensor: start read, eventid:1
311496840: [P154] DUCO Ext. CO2 Sensor: Read external CO2 sensor.
311496840: [P154] DUCO Ext. CO2 Sensor: Start read external sensor. NodeAddress: 3. Type: CO2
311496987: [P151] DUCO SER GW: Serial port in use, set flag to read data later.
311497177: [P154] DUCO Ext. CO2 Sensor: Command confirmed by ducobox
311497177: [P154] DUCO Ext. CO2 Sensor: End of message received.
311497177: [P154] DUCO Ext. CO2 Sensor: Stop reading from serial
311497734: [P151] DUCO SER GW: Start readNetworkList
311497886: [P151] DUCO SER GW: Received correct response on network
311497900: [P151] DUCO SER GW: Send command successfull!
311497926: [P151] DUCO SER GW: Ducobox row found!
311497927: [P151] DUCO SER GW: New Ventilationmode value: 1
311497927: [P151] DUCO SER GW: New Countdown value: 1800
311497928: [P151] DUCO SER GW: New Ventilation_Percentage value: 20
311497928: [P151] DUCO SER GW: New Current_Fan_Value value: 11

</details>

@arnemauer
Copy link
Owner

The RF-plugin doesn't receive an answer from the Ducobox. If you change the ventilation mode by pressing the blue buttons in Espeasy is the ducobox responding/changing ventilation speed?

@Jozziej
Copy link
Author

Jozziej commented Nov 17, 2022

When pressing the blue buttons in Espeasy the Duco is responding correctly, Duco_VentilationMode is showing the right value after a few seconds. But the Ventilation_gateway_RF plugin Ventilationmode stays on Automatic all the time.

@SkyThes

This comment was marked as off-topic.

@arnemauer
Copy link
Owner

What is the distance between the gateway and your ducobox? The gateway isn't receiving any rf message from the ducobox....

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment