Notifications
You must be signed in to change notification settings - Fork 0
/
ModbusLib.py
110 lines (94 loc) · 3.73 KB
/
ModbusLib.py
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
#!/usr/bin/env python
##
# @package ModbusLib Module containing all the modbus message construction related functions
#
##
# Function to get the Modbus CRC of the data provided
# @param data bytearray: data for which the CRC needs to be calculated
#
# @return crcs string: Modbus CRC of the given data in hex string format
#
def get_modbus_crc( data ):
crc = 0xFFFF
for pos in data:
crc ^= pos
for i in range(8):
if ((crc & 1) != 0):
crc >>= 1
crc ^= 0xA001
else:
crc >>= 1
crcs = "%04X"%(crc)
crcs = crcs[2:] + crcs[0:2]
return crcs
##
# Function to construct the Modbus message for in the RTU format
# @param slaveId int: slaveId of the controller to be queried
# @param funId int: function ID of the request
# @param startReg int: Starting register of the register set to be queried
# @param regCount int: Number of registers to be queried
#
# @return message string: Message to be sent to the controller in the format of hexadecimal string
def _constructRtuReadCommand( slaveId, funId, startReg, regCount ):
slaveIdHex = "%02X"%slaveId
funIdHex = "%02X"%funId
startRegHex = "%04X"%startReg
regCountHex = "%04X"%regCount
message = slaveIdHex + funIdHex + startRegHex + regCountHex
crc = get_modbus_crc( bytearray.fromhex( message ) )
message = message+crc
print( message )
return message
##
# Function to create the Modbus RTU message to read discrete coils
# @param slaveId int: slave ID of the controller to be queried
# @param startCoil int: Starting coil of the set to be queried
# @param coilCount int: Number of coils to be queried
#
# @return message bytearray: message to be sent to the Modbus controller to read holding register
#
def readDiscreteCoilsRtu( slaveId, startCoil, coilCount ):
funId = 1
message = _constructRtuReadCommand( slaveId, funId, startCoil, coilCount )
return bytearray.fromhex( message )
##
# Function to create the Modbus RTU message to read discrete inputs
# @param slaveId int: slave ID of the controller to be queried
# @param startReg int: Starting register of the register set to be queried
# @param regCount int: Number of registers to be queried
#
# @return message bytearray: message to be sent to the Modbus controller to read holding register
#
def readDiscreteInputRtu( slaveId, startReg, regCount ):
funId = 2
message = _constructRtuReadCommand( slaveId, funId, startReg, regCount )
return bytearray.fromhex( message )
##
# Function to create the Modbus RTU message to read holding register
# @param slaveId int: slave ID of the controller to be queried
# @param startReg int: Starting register of the register set to be queried
# @param regCount int: Number of registers to be queried
#
# @return message bytearray: message to be sent to the Modbus controller to read holding register
#
def readHoldingRegisterRtu( slaveId, startReg, regCount ):
funId = 3
message = _constructRtuReadCommand( slaveId, funId, startReg, regCount )
return bytearray.fromhex( message )
##
# Function to create the Modbus RTU message to read input register
# @param slaveId int: slave ID of the controller to be queried
# @param startReg int: Starting register of the register set to be queried
# @param regCount int: Number of registers to be queried
#
# @return message bytearray: message to be sent to the Modbus controller to read holding register
#
def readInputRegisterRtu( slaveId, startReg, regCount ):
funId = 4
message = _constructRtuReadCommand( slaveId, funId, startReg, regCount )
return bytearray.fromhex( message )
# TODO: Implement TCP command construction
##
#
def _constructTcpReadCommand( slaveId, funId, startReg, regCount ):
pass