Issue in UHK 80 while connecting over dongle #1133

Open
mohitt opened this issue Feb 15, 2025 · 7 comments
Open

Issue in UHK 80 while connecting over dongle #1133

mohitt opened this issue Feb 15, 2025 · 7 comments

Comments

@mohitt
Copy link

mohitt commented Feb 15, 2025

This happens only with firmware 12.3.3 onwards and my usb dongle connection.

My keyboard stops taking any input and if I start the UHK Agent and connect over USB I see following messages

D>>> Messanger message pool space ran out!

D>>> Messanger message pool space ran out!

D>>> Messanger message pool space ran out!

D>>> Messanger message pool space ran out!

D>>> Messanger message pool space ran out!

D>>> Messanger message pool space ran out!

D>>> Messanger message pool space ran out!

D>

Image

@mohitt
Copy link
Author

mohitt commented Feb 16, 2025

It is annoying that keyboard stops working and no way to fix it but wait. For it to go standby and power out

@kareltucek
Copy link
Collaborator

kareltucek commented Feb 16, 2025

Sorry! Yes, I know about it.

Powercycling the right half or the dongle should help temporarily.

As for a proper fix, it would help if we can figure out a way to reproduce it, or at least figure out the conditions when it tends to happen.

(Also, always make sure your dongle is on the exactly same firmware as the right half.)

@mohitt
Copy link
Author

mohitt commented Feb 16, 2025

@kareltucek how should I power cycle only way I know is to let it sleep and leave it for a few minutes. but, that is really annoying.

@mondalaci
Copy link
Member

With the recessed reset button on the bottom.

@mohitt
Copy link
Author

mohitt commented Feb 16, 2025 via email

@rkoopmann
Copy link

rkoopmann commented Feb 18, 2025

I'm getting the same error with direct & indirect connection of each half (with and without bridge cable). I have a wired connection from UHK80 (firmware 12.3.3) to MBP M3.

Possibly related, in uhkagent, I'm seeing the touchpad plugin pop in briefly before disappearing. I've never connected a touchpad module to this keyboard. here's a gif

Image

here's another

Image

After a day or so, the display shows a triangle shape and the keyboard eventually becomes unresponsive; Reflashing to the same firmware seems to clear message pool space, but the phantom touchpad module remains an issue. After a day or so, same thing happens.

@pcooke9
Copy link

pcooke9 commented Feb 18, 2025

I'm seeing the touchpad plugin pop in briefly before disappearing

This is fixed with: https://github.com/UltimateHackingKeyboard/firmware/releases/tag/v12.3.4