From 99c4988b9489012d5019afbff4bf5ce8158f582d Mon Sep 17 00:00:00 2001 From: David Jansen Date: Wed, 11 Dec 2024 18:01:43 +0000 Subject: [PATCH] Update 'docs' folder with PGorzalka_issue1080_ROM-soil-and-zone-borders and delete old branches. --- .../naming_violations.txt | 360 +++++++++--------- .../ThermalZones/comparison-dymola.log | 84 ++-- .../ThermalZones/simulator-dymola.log | 77 ++-- 3 files changed, 260 insertions(+), 261 deletions(-) diff --git a/docs/PGorzalka_issue1080_ROM-soil-and-zone-borders/naming_violations.txt b/docs/PGorzalka_issue1080_ROM-soil-and-zone-borders/naming_violations.txt index 268c22de03..4df5d6d0d7 100644 --- a/docs/PGorzalka_issue1080_ROM-soil-and-zone-borders/naming_violations.txt +++ b/docs/PGorzalka_issue1080_ROM-soil-and-zone-borders/naming_violations.txt @@ -1,6 +1,154 @@ +AixLib/DataBase/ThermalZones/ZoneBaseRecord.mo +1: Name 'withAirCap' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: with. Affected line: parameter Boolean withAirCap = true "Consider capacity of indoor air"; + +2: Name 'nOrientations' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Orientations. Affected line: parameter Integer nOrientations(min=1) "Number of total facades with different combination of tilt and orientation"; + +3: Name 'ATransparent' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Transparent. Affected line: parameter Modelica.Units.SI.Area ATransparent[nOrientations] "Areas of transparent (solar radiation transmittend) elements by orientations"; + +4: Name 'gWin' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: g. Affected line: parameter Modelica.Units.SI.TransmissionCoefficient gWin "Total energy transmittance of windows"; + +5: Name 'ratioWinConRad' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: ratio. Affected line: parameter Real ratioWinConRad "Ratio for windows between convective and radiative heat emission"; + +6: Name 'AFloor' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Floor. Affected line: parameter Modelica.Units.SI.Area AFloor "Area of floor plate"; + +7: Name 'hConFloor' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Floor. Affected line: parameter Modelica.Units.SI.CoefficientOfHeatTransfer hConFloor "Convective coefficient of heat transfer of floor plate (indoor)"; + +8: Name 'nFloor' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Floor. Affected line: parameter Integer nFloor(min=1) "Number of RC-elements of floor plate"; + +9: Name 'RFloor' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Floor. Affected line: parameter Modelica.Units.SI.ThermalResistance RFloor[nFloor] "Resistances of floor plate, from inside to outside"; + +10: Name 'RFloorRem' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Floor. Affected line: parameter Modelica.Units.SI.ThermalResistance RFloorRem "Resistance of remaining resistor RFloorRem between capacity n and outside"; + +11: Name 'CFloor' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Floor. Affected line: parameter Modelica.Units.SI.HeatCapacity CFloor[nFloor] "Heat capacities of floor plate, from inside to outside"; + +12: Name 'ARoof' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Roof. Affected line: parameter Modelica.Units.SI.Area ARoof "Area of roof"; + +13: Name 'hConRoof' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Roof. Affected line: parameter Modelica.Units.SI.CoefficientOfHeatTransfer hConRoof "Convective coefficient of heat transfer of roof (indoor)"; + +14: Name 'nRoof' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Roof. Affected line: parameter Integer nRoof(min=1) "Number of RC-elements of roof"; + +15: Name 'RRoof' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Roof. Affected line: parameter Modelica.Units.SI.ThermalResistance RRoof[nRoof] "Resistances of roof, from inside to outside"; + +16: Name 'RRoofRem' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Roof. Affected line: parameter Modelica.Units.SI.ThermalResistance RRoofRem "Resistance of remaining resistor RRoofRem between capacity n and outside"; + +17: Name 'CRoof' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Roof. Affected line: parameter Modelica.Units.SI.HeatCapacity CRoof[nRoof] "Heat capacities of roof, from inside to outside"; + +18: Could not extract name from line and check correctness, is your type specification correct (full library path)?. Affected line: parameter .Modelica.Units.SI.HeatCapacity CIze[nIze,nIzeRC]={{0.00001}} "Heat capacities of interzonal elements, from inside to outside"; + +19: Name 'nOrientationsRoof' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Orientations, Roof. Affected line: parameter Integer nOrientationsRoof(min=1) "Number of orientations for roof"; + +20: Name 'tiltRoof' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: tilt, Roof. Affected line: parameter Modelica.Units.SI.Angle tiltRoof[nOrientationsRoof] "Tilts of roof"; + +21: Name 'aziRoof' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Roof. Affected line: parameter Modelica.Units.SI.Angle aziRoof[nOrientationsRoof] "Azimuths of roof"; + +22: Name 'wfRoof' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: wf, Roof. Affected line: parameter Real wfRoof[nOrientationsRoof] "Weight factors of the roof"; + +23: Name 'aRoof' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: a, Roof. Affected line: parameter Modelica.Units.SI.Emissivity aRoof "Coefficient of absorption of roof (outdoor)"; + +24: Name 'aExt' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: a. Affected line: parameter Modelica.Units.SI.Emissivity aExt "Coefficient of absorption of exterior walls (outdoor)"; + +25: Name 'TSoil' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Soil. Affected line: parameter Modelica.Units.SI.Temperature TSoil "Temperature of soil (used for outside surface temperature of floors and thermal radiation)"; + +26: Name 'hConWallOut' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Wall. Affected line: parameter Modelica.Units.SI.CoefficientOfHeatTransfer hConWallOut "Exterior walls convective coefficient of heat transfer (outdoor)"; + +27: Name 'hRadWall' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Wall. Affected line: parameter Modelica.Units.SI.CoefficientOfHeatTransfer hRadWall "Coefficient of heat transfer for linearized radiation for exterior walls"; + +28: Name 'hConRoofOut' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Roof. Affected line: parameter Modelica.Units.SI.CoefficientOfHeatTransfer hConRoofOut "Roof's convective coefficient of heat transfer (outdoor)"; + +29: Name 'hRadRoof' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Roof. Affected line: parameter Modelica.Units.SI.CoefficientOfHeatTransfer hRadRoof "Coefficient of heat transfer for linearized radiation for roof"; + +30: Name 'tiltExtWalls' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: tilt, Walls. Affected line: parameter Modelica.Units.SI.Angle tiltExtWalls[nOrientations] "Tilts of exterior walls"; + +31: Name 'aziExtWalls' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Walls. Affected line: parameter Modelica.Units.SI.Angle aziExtWalls[nOrientations] "Azimuths of exterior walls"; + +32: Name 'wfWall' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: wf, Wall. Affected line: parameter Real wfWall[nOrientations] "Weight factors of the walls"; + +33: Name 'wfWin' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: wf. Affected line: parameter Real wfWin[nOrientations] "Weight factors of the windows"; + +34: Name 'wfGro' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: wf. Affected line: parameter Real wfGro "Weight factor of the ground"; + +35: Name 'specificPeople' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: specific, People. Affected line: parameter Real specificPeople "people per squaremeter"; + +36: Name 'activityDegree' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: activity, Degree. Affected line: parameter Real activityDegree "acitivity degree of people in met"; + +37: Name 'fixedHeatFlowRatePersons' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: fixed, Heat, Rate, Persons. Affected line: parameter Modelica.Units.SI.HeatFlowRate fixedHeatFlowRatePersons "Area specific heatflowrate by persons in case of temperature independent calculation"; + +38: Name 'ratioConvectiveHeatPeople' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: ratio, Convective, Heat, People. Affected line: parameter Real ratioConvectiveHeatPeople "Ratio of convective heat from overall heat output for people"; + +39: Name 'internalGainsMoistureNoPeople' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: internal, Gains, Moisture, People. Affected line: parameter Real internalGainsMoistureNoPeople "internal moisture production of plants, etc. except from people in g/(h m²)"; + +40: Name 'internalGainsMachinesSpecific' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: internal, Gains, Machines, Specific. Affected line: parameter Real internalGainsMachinesSpecific "Heat Flux of machines"; + +41: Name 'ratioConvectiveHeatMachines' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: ratio, Convective, Heat, Machines. Affected line: parameter Real ratioConvectiveHeatMachines "Ratio of convective heat from overall heat output for machines"; + +42: Name 'lightingPowerSpecific' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: lighting, Power, Specific. Affected line: parameter Modelica.Units.SI.HeatFlux lightingPowerSpecific "Heat flux of lighting"; + +43: Name 'ratioConvectiveHeatLighting' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: ratio, Convective, Heat, Lighting. Affected line: parameter Real ratioConvectiveHeatLighting "Ratio of convective heat from overall heat output for lights"; + +44: Name 'useConstantACHrate' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Constant, Hrate. Affected line: parameter Boolean useConstantACHrate "Choose if a constant infiltration rate is used"; + +45: Name 'baseACH' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: base. Affected line: parameter Real baseACH "Base ACH rate for ventilation controller"; + +46: Name 'maxUserACH' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: User. Affected line: parameter Real maxUserACH "Additional ACH value for max. user activity"; + +47: Name 'maxOverheatingACH' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Overheating. Affected line: parameter Real maxOverheatingACH[2] "Additional ACH value when overheating appears, transition range"; + +48: Name 'maxSummerACH' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Summer. Affected line: parameter Real maxSummerACH[3] "Additional ACH in summer, Tmin, Tmax"; + +49: Name 'winterReduction' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: winter, Reduction. Affected line: parameter Real winterReduction[3] "Reduction factor of userACH for cold weather"; + +50: Name 'withAHU' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: with. Affected line: parameter Boolean withAHU "Zone is connected to central air handling unit"; + +51: Name 'shadingFactor' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: shading, Factor. Affected line: parameter Real shadingFactor[nOrientations] "Fc-Value: Factor representing how much of the actual solar irradiation goes through the sunblind and enters the window element, for the case, that the sunblind is activated. Defaults to 1, i.e. no shading is active. External sunblinds."; + +52: Name 'hHeat' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Heat. Affected line: parameter Real hHeat "Upper limit controller output"; + +53: Name 'lHeat' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: l, Heat. Affected line: parameter Real lHeat "Lower limit controller output"; + +54: Name 'KRHeat' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: K, Heat. Affected line: parameter Real KRHeat "Gain of the controller"; + +55: Name 'TNHeat' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: N, Heat. Affected line: parameter Modelica.Units.SI.Time TNHeat "Time constant of the controller"; + +56: Name 'HeaterOn' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Heater. Affected line: parameter Boolean HeaterOn "Use heater component"; + +57: Name 'hCool' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Cool. Affected line: parameter Real hCool "Upper limit controller output"; + +58: Name 'lCool' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: l, Cool. Affected line: parameter Real lCool "Lower limit controller output"; + +59: Name 'heaLoadFacOut' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Load. Affected line: parameter Modelica.Units.SI.ThermalConductance heaLoadFacOut "Factor for heat load calculation (part 1) , needs to be multiplied with (indoor set temperature - nominal outside temperature)"; + +60: Name 'heaLoadFacGrd' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Load. Affected line: parameter Modelica.Units.SI.ThermalConductance heaLoadFacGrd "Factor for heat load calculation, (part 2), needs to be multiplied with (indoor set temperature - nominal ground temperature)"; + +61: Name 'KRCool' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: K, Cool. Affected line: parameter Real KRCool "Gain of the controller"; + +62: Name 'TNCool' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: N, Cool. Affected line: parameter Modelica.Units.SI.Time TNCool "Time constant of the controller"; + +63: Name 'CoolerOn' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Cooler. Affected line: parameter Boolean CoolerOn "Use chiller component"; + +64: Name 'TThresholdHeater' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Threshold, Heater. Affected line: parameter Modelica.Units.SI.Temperature TThresholdHeater "Threshold temperature below ideal heater is used"; + +65: Name 'TThresholdCooler' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Threshold, Cooler. Affected line: parameter Modelica.Units.SI.Temperature TThresholdCooler "Threshold temperature above ideal cooler is used"; + +66: Name 'withIdealThresholds' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: with, Ideal, Thresholds. Affected line: parameter Boolean withIdealThresholds "Sets if the threshold temperatures for ideal heater and cooler should be used"; + + +AixLib/Fluid/Pools/BaseClasses/AirFlowMoistureToROM.mo +1: Missing documentation, Name 'nPools' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Pools. Affected line: parameter Integer nPools = 1; + +2: Name 'm_flow_eva' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: m_flow_eva. Affected line: Modelica.Blocks.Interfaces.RealInput m_flow_eva[nPools] "Water mass flow due to evaporation" annotation (Placement(transformation( extent={{120,-44},{88,-12}}), iconTransformation(extent={{108,-50},{ 82,-24}}))); + +3: Could not extract name from line and check correctness, is your type specification correct (full library path)?. Affected line: MixingVolumes.MixingVolumeMoistAir AirLay( redeclare package Medium = AirMedium, T_start=303.15, V=VAirLay, energyDynamics=energyDynamics, m_flow_nominal=m_flow_air_nominal, nPorts=2) "Air layer above swimming pool, relevant for evaporation" annotation (Placement(transformation(extent={{-4,42},{-24,62}})));Movers.FlowControlled_m_flow sou( redeclare package Medium = AirMedium, energyDynamics=energyDynamics, m_flow_nominal=m_flow_air_nominal, addPowerToMedium=false, nominalValuesDefineDefaultPressureCurve=true) annotation (Placement(transformation(extent={{-24,-42},{-46, -16}}))); + +4: Missing documentation, Name 'Sum_m_flow_eva' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Sum_m_flow_eva. Affected line: Modelica.Blocks.Math.MultiSum Sum_m_flow_eva(nu=nPools) annotation (Placement(transformation(extent={{76,-34},{64,-22}}))); + +5: Missing documentation. Affected line: Modelica.Blocks.Math.MultiSum SumQEva(nu=nPools) annotation (Placement(transformation(extent={{76,34},{60,50}}))); + +6: Missing documentation, Name 'prescribedHeatFlow' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: prescribed, Heat. Affected line: Modelica.Thermal.HeatTransfer.Sources.PrescribedHeatFlow prescribedHeatFlow annotation (Placement(transformation(extent={{48,32},{28,52}}))); + + AixLib/ThermalZones/ReducedOrder/ThermalZone/ThermalZone.mo 1: Name 'corG' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: G. Affected line: replaceable model corG = SolarGain.CorrectionGDoublePane constrainedby AixLib.ThermalZones.ReducedOrder.SolarGain.BaseClasses.PartialCorrectionG "Model for correction of solar transmission" annotation(choicesAllMatching=true); @@ -117,18 +265,42 @@ AixLib/ThermalZones/ReducedOrder/ThermalZone/ThermalZone.mo 57: Missing documentation, Name 'QIntGainsInternalTot_flow' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Gains, Internal. Affected line: Modelica.Blocks.Sources.RealExpression QIntGainsInternalTot_flow[3](y={-lights.convHeat.Q_flow - lights.radHeat.Q_flow,-machinesSenHea.radHeat.Q_flow - machinesSenHea.convHeat.Q_flow, -humanTotHeaDependent.radHeat.Q_flow - humanTotHeaDependent.convHeat.Q_flow}) if ATot > 0 and internalGainsMode == 3 annotation (Placement(transformation(extent={{94,-46},{98,-34}}))); -AixLib/Fluid/Pools/BaseClasses/AirFlowMoistureToROM.mo -1: Missing documentation, Name 'nPools' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Pools. Affected line: parameter Integer nPools = 1; +AixLib/ThermalZones/ReducedOrder/ThermalZone/BaseClasses/PartialThermalZone.mo +1: Could not extract name from line and check correctness, is your type specification correct (full library path)?. Affected line: replaceable parameter DataBase.ThermalZones.ZoneBaseRecord zoneParam "Choose setup for this zone" annotation (choicesAllMatching=true); -2: Name 'm_flow_eva' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: m_flow_eva. Affected line: Modelica.Blocks.Interfaces.RealInput m_flow_eva[nPools] "Water mass flow due to evaporation" annotation (Placement(transformation( extent={{120,-44},{88,-12}}), iconTransformation(extent={{108,-50},{ 82,-24}}))); +2: Name 'nPorts' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Ports. Affected line: parameter Integer nPorts = 0 "Number of fluid ports" annotation(Evaluate=true, Dialog(connectorSizing=true, tab="General",group="Ports")); -3: Could not extract name from line and check correctness, is your type specification correct (full library path)?. Affected line: MixingVolumes.MixingVolumeMoistAir AirLay( redeclare package Medium = AirMedium, T_start=303.15, V=VAirLay, energyDynamics=energyDynamics, m_flow_nominal=m_flow_air_nominal, nPorts=2) "Air layer above swimming pool, relevant for evaporation" annotation (Placement(transformation(extent={{-4,42},{-24,62}})));Movers.FlowControlled_m_flow sou( redeclare package Medium = AirMedium, energyDynamics=energyDynamics, m_flow_nominal=m_flow_air_nominal, addPowerToMedium=false, nominalValuesDefineDefaultPressureCurve=true) annotation (Placement(transformation(extent={{-24,-42},{-46, -16}}))); +3: Name 'nPortsROM' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Ports. Affected line: final parameter Integer nPortsROM = if use_pools then nPorts + 2 else nPorts "Number of fluid ports" annotation(Evaluate=true, Dialog(connectorSizing=true, tab="General",group="Ports")); -4: Missing documentation, Name 'Sum_m_flow_eva' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Sum_m_flow_eva. Affected line: Modelica.Blocks.Math.MultiSum Sum_m_flow_eva(nu=nPools) annotation (Placement(transformation(extent={{76,-34},{64,-22}}))); +4: Name 'use_moisture_balance' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: use_moisture_balance. Affected line: parameter Boolean use_moisture_balance=false "If true, input connector QLat_flow is enabled and room air computes moisture balance" annotation (Dialog(tab="Moisture")); -5: Missing documentation. Affected line: Modelica.Blocks.Math.MultiSum SumQEva(nu=nPools) annotation (Placement(transformation(extent={{76,34},{60,50}}))); +5: Name 'intGains' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Gains. Affected line: Modelica.Blocks.Interfaces.RealInput intGains[3] "Input profiles for internal gains persons, machines, light" annotation ( Placement(transformation( extent={{-20,-20},{20,20}}, rotation=90, origin={80,-100}), iconTransformation( extent={{-12,-12},{12,12}}, rotation=90, origin={80,-84}))); -6: Missing documentation, Name 'prescribedHeatFlow' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: prescribed, Heat. Affected line: Modelica.Thermal.HeatTransfer.Sources.PrescribedHeatFlow prescribedHeatFlow annotation (Placement(transformation(extent={{48,32},{28,52}}))); +6: Could not extract name from line and check correctness, is your type specification correct (full library path)?. Affected line: BoundaryConditions.WeatherData.Bus weaBus "Weather data bus" annotation (Placement( transformation(extent={{-117,18},{-83,50}}), iconTransformation( extent={{-110,50},{-90,70}}))); + +7: Name 'ports' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: ports. Affected line: Modelica.Fluid.Vessels.BaseClasses.VesselFluidPorts_b ports[nPorts]( redeclare each final package Medium = Medium) "Auxilliary fluid inlets and outlets to indoor air volume" annotation (Placement(transformation(extent={{-49,-108},{49,-84}}), iconTransformation(extent={{-47,-84},{47,-60}}))); + +8: Name 'intGainsConv' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Gains, Conv. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a intGainsConv if ATot > 0 or zoneParam.VAir > 0 "Convective internal gains" annotation (Placement(transformation(extent={{94,10},{114,30}}), iconTransformation(extent={{92,-6},{112,14}}))); + +9: Name 'intGainsRad' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Gains. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a intGainsRad if ATot > 0 "Radiative internal gains" annotation (Placement(transformation(extent={{94,30},{114,50}}), iconTransformation(extent={{92,24},{112,44}}))); + + +AixLib/ThermalZones/ReducedOrder/Examples/MultizoneInterzonalsFixedHeater.mo +1: Name 'tableInternalGains' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: table, Internal, Gains. Affected line: Modelica.Blocks.Sources.CombiTimeTable tableInternalGains( tableOnFile=true, extrapolation=Modelica.Blocks.Types.Extrapolation.Periodic, tableName="Internals", fileName=Modelica.Utilities.Files.loadResource("modelica://AixLib/Resources/LowOrder_ExampleData/InternalGains_MorschenichSfhFixedHeater.txt"), columns=2:10) "Profiles for internal gains" annotation (Placement(transformation(extent={{72,-42},{56,-26}}))); + +2: Name 'tableAHU' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: table. Affected line: Modelica.Blocks.Sources.CombiTimeTable tableAHU( tableOnFile=true, extrapolation=Modelica.Blocks.Types.Extrapolation.Periodic, tableName="AHU", columns=2:5, fileName=Modelica.Utilities.Files.loadResource("modelica://AixLib/Resources/LowOrder_ExampleData/AHU_MorschenichSfhFixedHeater.txt")) "Boundary conditions for air handling unit" annotation (Placement(transformation(extent={{-64,-6},{-48,10}}))); + +3: Name 'tableTSet' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: table. Affected line: Modelica.Blocks.Sources.CombiTimeTable tableTSet( tableOnFile=true, tableName="Tset", extrapolation=Modelica.Blocks.Types.Extrapolation.Periodic, fileName=Modelica.Utilities.Files.loadResource("modelica://AixLib/Resources/LowOrder_ExampleData/TsetHeat_MorschenichSfhFixedHeater.txt"), columns=2:4) "Set points for heater" annotation (Placement(transformation(extent={{72,-66},{56,-50}}))); + +4: Name 'tableTSetCool' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: table, Cool. Affected line: Modelica.Blocks.Sources.CombiTimeTable tableTSetCool( tableOnFile=true, tableName="Tset", extrapolation=Modelica.Blocks.Types.Extrapolation.Periodic, fileName=Modelica.Utilities.Files.loadResource("modelica://AixLib/Resources/LowOrder_ExampleData/TsetCool_MorschenichSfhFixedHeater.txt"), columns=2:4) "Set points for cooler" annotation (Placement(transformation(extent={{72,-90},{56,-74}}))); + +5: Name 'tableIntGainsRad' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: table, Gains. Affected line: Modelica.Blocks.Sources.CombiTimeTable tableIntGainsRad( tableOnFile=true, tableName="IntGainsConvRad", extrapolation=Modelica.Blocks.Types.Extrapolation.Periodic, fileName=Modelica.Utilities.Files.loadResource("modelica://AixLib/Resources/LowOrder_ExampleData/MorschenichSfhFixedHeater_AddIntGains.txt"), columns=2:4) "Additional internal gains (radiative)" annotation (Placement(transformation(extent={{-64,-34},{-48,-18}}))); + +6: Missing documentation, Name 'heatFlowRad' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: heat. Affected line: Modelica.Thermal.HeatTransfer.Sources.PrescribedHeatFlow heatFlowRad[3] annotation (Placement(transformation(extent={{-22,-36},{-2,-16}}))); + +7: Name 'tableIntGainsConv' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: table, Gains, Conv. Affected line: Modelica.Blocks.Sources.CombiTimeTable tableIntGainsConv( tableOnFile=true, tableName="IntGainsConvRad", extrapolation=Modelica.Blocks.Types.Extrapolation.Periodic, fileName=Modelica.Utilities.Files.loadResource("modelica://AixLib/Resources/LowOrder_ExampleData/MorschenichSfhFixedHeater_AddIntGains.txt"), columns=5:7) "Additional internal gains (convective)" annotation (Placement(transformation(extent={{-64,-72},{-48,-56}}))); + +8: Missing documentation, Name 'heatFlowConv' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: heat, Conv. Affected line: Modelica.Thermal.HeatTransfer.Sources.PrescribedHeatFlow heatFlowConv[3] annotation (Placement(transformation(extent={{-24,-74},{-4,-54}}))); AixLib/ThermalZones/ReducedOrder/Multizone/BaseClasses/PartialMultizone.mo @@ -194,176 +366,4 @@ AixLib/ThermalZones/ReducedOrder/Multizone/BaseClasses/PartialMultizone.mo 31: Name 'PCooler' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Cooler. Affected line: Modelica.Blocks.Interfaces.RealOutput PCooler[numZones](each final quantity="HeatFlowRate", each final unit="W") "Power for cooling" annotation ( Placement(transformation(extent={{100,-70},{120,-50}}),iconTransformation( extent={{80,-100},{100,-80}}))); -32: Name 'QIntGains_flow' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Gains. Affected line: Modelica.Blocks.Interfaces.RealOutput QIntGains_flow[numZones,3](each final quantity="HeatFlowRate", each final unit="W") if ASurTot > 0 or VAir > 0 "Heat flow based on internal gains for each zone from lights[1], machines[2], and persons[3]" annotation (Placement(transformation(extent={{100,-90},{ 120,-70}}), iconTransformation(extent={{80,-100},{100,-80}}))); - - -AixLib/ThermalZones/ReducedOrder/ThermalZone/BaseClasses/PartialThermalZone.mo -1: Could not extract name from line and check correctness, is your type specification correct (full library path)?. Affected line: replaceable parameter DataBase.ThermalZones.ZoneBaseRecord zoneParam "Choose setup for this zone" annotation (choicesAllMatching=true); - -2: Name 'nPorts' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Ports. Affected line: parameter Integer nPorts = 0 "Number of fluid ports" annotation(Evaluate=true, Dialog(connectorSizing=true, tab="General",group="Ports")); - -3: Name 'nPortsROM' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Ports. Affected line: final parameter Integer nPortsROM = if use_pools then nPorts + 2 else nPorts "Number of fluid ports" annotation(Evaluate=true, Dialog(connectorSizing=true, tab="General",group="Ports")); - -4: Name 'use_moisture_balance' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: use_moisture_balance. Affected line: parameter Boolean use_moisture_balance=false "If true, input connector QLat_flow is enabled and room air computes moisture balance" annotation (Dialog(tab="Moisture")); - -5: Name 'intGains' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Gains. Affected line: Modelica.Blocks.Interfaces.RealInput intGains[3] "Input profiles for internal gains persons, machines, light" annotation ( Placement(transformation( extent={{-20,-20},{20,20}}, rotation=90, origin={80,-100}), iconTransformation( extent={{-12,-12},{12,12}}, rotation=90, origin={80,-84}))); - -6: Could not extract name from line and check correctness, is your type specification correct (full library path)?. Affected line: BoundaryConditions.WeatherData.Bus weaBus "Weather data bus" annotation (Placement( transformation(extent={{-117,18},{-83,50}}), iconTransformation( extent={{-110,50},{-90,70}}))); - -7: Name 'ports' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: ports. Affected line: Modelica.Fluid.Vessels.BaseClasses.VesselFluidPorts_b ports[nPorts]( redeclare each final package Medium = Medium) "Auxilliary fluid inlets and outlets to indoor air volume" annotation (Placement(transformation(extent={{-49,-108},{49,-84}}), iconTransformation(extent={{-47,-84},{47,-60}}))); - -8: Name 'intGainsConv' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Gains, Conv. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a intGainsConv if ATot > 0 or zoneParam.VAir > 0 "Convective internal gains" annotation (Placement(transformation(extent={{94,10},{114,30}}), iconTransformation(extent={{92,-6},{112,14}}))); - -9: Name 'intGainsRad' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Gains. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a intGainsRad if ATot > 0 "Radiative internal gains" annotation (Placement(transformation(extent={{94,30},{114,50}}), iconTransformation(extent={{92,24},{112,44}}))); - - -AixLib/DataBase/ThermalZones/ZoneBaseRecord.mo -1: Name 'withAirCap' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: with. Affected line: parameter Boolean withAirCap = true "Consider capacity of indoor air"; - -2: Name 'nOrientations' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Orientations. Affected line: parameter Integer nOrientations(min=1) "Number of total facades with different combination of tilt and orientation"; - -3: Name 'ATransparent' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Transparent. Affected line: parameter Modelica.Units.SI.Area ATransparent[nOrientations] "Areas of transparent (solar radiation transmittend) elements by orientations"; - -4: Name 'gWin' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: g. Affected line: parameter Modelica.Units.SI.TransmissionCoefficient gWin "Total energy transmittance of windows"; - -5: Name 'ratioWinConRad' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: ratio. Affected line: parameter Real ratioWinConRad "Ratio for windows between convective and radiative heat emission"; - -6: Name 'AFloor' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Floor. Affected line: parameter Modelica.Units.SI.Area AFloor "Area of floor plate"; - -7: Name 'hConFloor' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Floor. Affected line: parameter Modelica.Units.SI.CoefficientOfHeatTransfer hConFloor "Convective coefficient of heat transfer of floor plate (indoor)"; - -8: Name 'nFloor' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Floor. Affected line: parameter Integer nFloor(min=1) "Number of RC-elements of floor plate"; - -9: Name 'RFloor' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Floor. Affected line: parameter Modelica.Units.SI.ThermalResistance RFloor[nFloor] "Resistances of floor plate, from inside to outside"; - -10: Name 'RFloorRem' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Floor. Affected line: parameter Modelica.Units.SI.ThermalResistance RFloorRem "Resistance of remaining resistor RFloorRem between capacity n and outside"; - -11: Name 'CFloor' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Floor. Affected line: parameter Modelica.Units.SI.HeatCapacity CFloor[nFloor] "Heat capacities of floor plate, from inside to outside"; - -12: Name 'ARoof' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Roof. Affected line: parameter Modelica.Units.SI.Area ARoof "Area of roof"; - -13: Name 'hConRoof' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Roof. Affected line: parameter Modelica.Units.SI.CoefficientOfHeatTransfer hConRoof "Convective coefficient of heat transfer of roof (indoor)"; - -14: Name 'nRoof' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Roof. Affected line: parameter Integer nRoof(min=1) "Number of RC-elements of roof"; - -15: Name 'RRoof' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Roof. Affected line: parameter Modelica.Units.SI.ThermalResistance RRoof[nRoof] "Resistances of roof, from inside to outside"; - -16: Name 'RRoofRem' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Roof. Affected line: parameter Modelica.Units.SI.ThermalResistance RRoofRem "Resistance of remaining resistor RRoofRem between capacity n and outside"; - -17: Name 'CRoof' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Roof. Affected line: parameter Modelica.Units.SI.HeatCapacity CRoof[nRoof] "Heat capacities of roof, from inside to outside"; - -18: Could not extract name from line and check correctness, is your type specification correct (full library path)?. Affected line: parameter .Modelica.Units.SI.HeatCapacity CIze[nIze,nIzeRC]={{0.00001}} "Heat capacities of interzonal elements, from inside to outside"; - -19: Name 'nOrientationsRoof' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Orientations, Roof. Affected line: parameter Integer nOrientationsRoof(min=1) "Number of orientations for roof"; - -20: Name 'tiltRoof' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: tilt, Roof. Affected line: parameter Modelica.Units.SI.Angle tiltRoof[nOrientationsRoof] "Tilts of roof"; - -21: Name 'aziRoof' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Roof. Affected line: parameter Modelica.Units.SI.Angle aziRoof[nOrientationsRoof] "Azimuths of roof"; - -22: Name 'wfRoof' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: wf, Roof. Affected line: parameter Real wfRoof[nOrientationsRoof] "Weight factors of the roof"; - -23: Name 'aRoof' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: a, Roof. Affected line: parameter Modelica.Units.SI.Emissivity aRoof "Coefficient of absorption of roof (outdoor)"; - -24: Name 'aExt' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: a. Affected line: parameter Modelica.Units.SI.Emissivity aExt "Coefficient of absorption of exterior walls (outdoor)"; - -25: Name 'TSoil' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Soil. Affected line: parameter Modelica.Units.SI.Temperature TSoil "Temperature of soil (used for outside surface temperature of floors and thermal radiation)"; - -26: Name 'hConWallOut' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Wall. Affected line: parameter Modelica.Units.SI.CoefficientOfHeatTransfer hConWallOut "Exterior walls convective coefficient of heat transfer (outdoor)"; - -27: Name 'hRadWall' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Wall. Affected line: parameter Modelica.Units.SI.CoefficientOfHeatTransfer hRadWall "Coefficient of heat transfer for linearized radiation for exterior walls"; - -28: Name 'hConRoofOut' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Roof. Affected line: parameter Modelica.Units.SI.CoefficientOfHeatTransfer hConRoofOut "Roof's convective coefficient of heat transfer (outdoor)"; - -29: Name 'hRadRoof' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Roof. Affected line: parameter Modelica.Units.SI.CoefficientOfHeatTransfer hRadRoof "Coefficient of heat transfer for linearized radiation for roof"; - -30: Name 'tiltExtWalls' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: tilt, Walls. Affected line: parameter Modelica.Units.SI.Angle tiltExtWalls[nOrientations] "Tilts of exterior walls"; - -31: Name 'aziExtWalls' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Walls. Affected line: parameter Modelica.Units.SI.Angle aziExtWalls[nOrientations] "Azimuths of exterior walls"; - -32: Name 'wfWall' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: wf, Wall. Affected line: parameter Real wfWall[nOrientations] "Weight factors of the walls"; - -33: Name 'wfWin' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: wf. Affected line: parameter Real wfWin[nOrientations] "Weight factors of the windows"; - -34: Name 'wfGro' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: wf. Affected line: parameter Real wfGro "Weight factor of the ground"; - -35: Name 'specificPeople' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: specific, People. Affected line: parameter Real specificPeople "people per squaremeter"; - -36: Name 'activityDegree' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: activity, Degree. Affected line: parameter Real activityDegree "acitivity degree of people in met"; - -37: Name 'fixedHeatFlowRatePersons' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: fixed, Heat, Rate, Persons. Affected line: parameter Modelica.Units.SI.HeatFlowRate fixedHeatFlowRatePersons "Area specific heatflowrate by persons in case of temperature independent calculation"; - -38: Name 'ratioConvectiveHeatPeople' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: ratio, Convective, Heat, People. Affected line: parameter Real ratioConvectiveHeatPeople "Ratio of convective heat from overall heat output for people"; - -39: Name 'internalGainsMoistureNoPeople' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: internal, Gains, Moisture, People. Affected line: parameter Real internalGainsMoistureNoPeople "internal moisture production of plants, etc. except from people in g/(h m²)"; - -40: Name 'internalGainsMachinesSpecific' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: internal, Gains, Machines, Specific. Affected line: parameter Real internalGainsMachinesSpecific "Heat Flux of machines"; - -41: Name 'ratioConvectiveHeatMachines' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: ratio, Convective, Heat, Machines. Affected line: parameter Real ratioConvectiveHeatMachines "Ratio of convective heat from overall heat output for machines"; - -42: Name 'lightingPowerSpecific' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: lighting, Power, Specific. Affected line: parameter Modelica.Units.SI.HeatFlux lightingPowerSpecific "Heat flux of lighting"; - -43: Name 'ratioConvectiveHeatLighting' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: ratio, Convective, Heat, Lighting. Affected line: parameter Real ratioConvectiveHeatLighting "Ratio of convective heat from overall heat output for lights"; - -44: Name 'useConstantACHrate' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Constant, Hrate. Affected line: parameter Boolean useConstantACHrate "Choose if a constant infiltration rate is used"; - -45: Name 'baseACH' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: base. Affected line: parameter Real baseACH "Base ACH rate for ventilation controller"; - -46: Name 'maxUserACH' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: User. Affected line: parameter Real maxUserACH "Additional ACH value for max. user activity"; - -47: Name 'maxOverheatingACH' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Overheating. Affected line: parameter Real maxOverheatingACH[2] "Additional ACH value when overheating appears, transition range"; - -48: Name 'maxSummerACH' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Summer. Affected line: parameter Real maxSummerACH[3] "Additional ACH in summer, Tmin, Tmax"; - -49: Name 'winterReduction' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: winter, Reduction. Affected line: parameter Real winterReduction[3] "Reduction factor of userACH for cold weather"; - -50: Name 'withAHU' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: with. Affected line: parameter Boolean withAHU "Zone is connected to central air handling unit"; - -51: Name 'shadingFactor' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: shading, Factor. Affected line: parameter Real shadingFactor[nOrientations] "Fc-Value: Factor representing how much of the actual solar irradiation goes through the sunblind and enters the window element, for the case, that the sunblind is activated. Defaults to 1, i.e. no shading is active. External sunblinds."; - -52: Name 'hHeat' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Heat. Affected line: parameter Real hHeat "Upper limit controller output"; - -53: Name 'lHeat' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: l, Heat. Affected line: parameter Real lHeat "Lower limit controller output"; - -54: Name 'KRHeat' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: K, Heat. Affected line: parameter Real KRHeat "Gain of the controller"; - -55: Name 'TNHeat' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: N, Heat. Affected line: parameter Modelica.Units.SI.Time TNHeat "Time constant of the controller"; - -56: Name 'HeaterOn' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Heater. Affected line: parameter Boolean HeaterOn "Use heater component"; - -57: Name 'hCool' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Cool. Affected line: parameter Real hCool "Upper limit controller output"; - -58: Name 'lCool' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: l, Cool. Affected line: parameter Real lCool "Lower limit controller output"; - -59: Name 'heaLoadFacOut' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Load. Affected line: parameter Modelica.Units.SI.ThermalConductance heaLoadFacOut "Factor for heat load calculation (part 1) , needs to be multiplied with (indoor set temperature - nominal outside temperature)"; - -60: Name 'heaLoadFacGrd' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Load. Affected line: parameter Modelica.Units.SI.ThermalConductance heaLoadFacGrd "Factor for heat load calculation, (part 2), needs to be multiplied with (indoor set temperature - nominal ground temperature)"; - -61: Name 'KRCool' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: K, Cool. Affected line: parameter Real KRCool "Gain of the controller"; - -62: Name 'TNCool' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: N, Cool. Affected line: parameter Modelica.Units.SI.Time TNCool "Time constant of the controller"; - -63: Name 'CoolerOn' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Cooler. Affected line: parameter Boolean CoolerOn "Use chiller component"; - -64: Name 'TThresholdHeater' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Threshold, Heater. Affected line: parameter Modelica.Units.SI.Temperature TThresholdHeater "Threshold temperature below ideal heater is used"; - -65: Name 'TThresholdCooler' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Threshold, Cooler. Affected line: parameter Modelica.Units.SI.Temperature TThresholdCooler "Threshold temperature above ideal cooler is used"; - -66: Name 'withIdealThresholds' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: with, Ideal, Thresholds. Affected line: parameter Boolean withIdealThresholds "Sets if the threshold temperatures for ideal heater and cooler should be used"; - - -AixLib/ThermalZones/ReducedOrder/Examples/MultizoneInterzonalsFixedHeater.mo -1: Name 'tableInternalGains' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: table, Internal, Gains. Affected line: Modelica.Blocks.Sources.CombiTimeTable tableInternalGains( tableOnFile=true, extrapolation=Modelica.Blocks.Types.Extrapolation.Periodic, tableName="Internals", fileName=Modelica.Utilities.Files.loadResource("modelica://AixLib/Resources/LowOrder_ExampleData/InternalGains_MorschenichSfhFixedHeater.txt"), columns=2:10) "Profiles for internal gains" annotation (Placement(transformation(extent={{72,-42},{56,-26}}))); - -2: Name 'tableAHU' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: table. Affected line: Modelica.Blocks.Sources.CombiTimeTable tableAHU( tableOnFile=true, extrapolation=Modelica.Blocks.Types.Extrapolation.Periodic, tableName="AHU", columns=2:5, fileName=Modelica.Utilities.Files.loadResource("modelica://AixLib/Resources/LowOrder_ExampleData/AHU_MorschenichSfhFixedHeater.txt")) "Boundary conditions for air handling unit" annotation (Placement(transformation(extent={{-64,-6},{-48,10}}))); - -3: Name 'tableTSet' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: table. Affected line: Modelica.Blocks.Sources.CombiTimeTable tableTSet( tableOnFile=true, tableName="Tset", extrapolation=Modelica.Blocks.Types.Extrapolation.Periodic, fileName=Modelica.Utilities.Files.loadResource("modelica://AixLib/Resources/LowOrder_ExampleData/TsetHeat_MorschenichSfhFixedHeater.txt"), columns=2:4) "Set points for heater" annotation (Placement(transformation(extent={{72,-66},{56,-50}}))); - -4: Name 'tableTSetCool' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: table, Cool. Affected line: Modelica.Blocks.Sources.CombiTimeTable tableTSetCool( tableOnFile=true, tableName="Tset", extrapolation=Modelica.Blocks.Types.Extrapolation.Periodic, fileName=Modelica.Utilities.Files.loadResource("modelica://AixLib/Resources/LowOrder_ExampleData/TsetCool_MorschenichSfhFixedHeater.txt"), columns=2:4) "Set points for cooler" annotation (Placement(transformation(extent={{72,-90},{56,-74}}))); - -5: Name 'tableIntGainsRad' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: table, Gains. Affected line: Modelica.Blocks.Sources.CombiTimeTable tableIntGainsRad( tableOnFile=true, tableName="IntGainsConvRad", extrapolation=Modelica.Blocks.Types.Extrapolation.Periodic, fileName=Modelica.Utilities.Files.loadResource("modelica://AixLib/Resources/LowOrder_ExampleData/MorschenichSfhFixedHeater_AddIntGains.txt"), columns=2:4) "Additional internal gains (radiative)" annotation (Placement(transformation(extent={{-64,-34},{-48,-18}}))); - -6: Missing documentation, Name 'heatFlowRad' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: heat. Affected line: Modelica.Thermal.HeatTransfer.Sources.PrescribedHeatFlow heatFlowRad[3] annotation (Placement(transformation(extent={{-22,-36},{-2,-16}}))); - -7: Name 'tableIntGainsConv' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: table, Gains, Conv. Affected line: Modelica.Blocks.Sources.CombiTimeTable tableIntGainsConv( tableOnFile=true, tableName="IntGainsConvRad", extrapolation=Modelica.Blocks.Types.Extrapolation.Periodic, fileName=Modelica.Utilities.Files.loadResource("modelica://AixLib/Resources/LowOrder_ExampleData/MorschenichSfhFixedHeater_AddIntGains.txt"), columns=5:7) "Additional internal gains (convective)" annotation (Placement(transformation(extent={{-64,-72},{-48,-56}}))); - -8: Missing documentation, Name 'heatFlowConv' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: heat, Conv. Affected line: Modelica.Thermal.HeatTransfer.Sources.PrescribedHeatFlow heatFlowConv[3] annotation (Placement(transformation(extent={{-24,-74},{-4,-54}}))); \ No newline at end of file +32: Name 'QIntGains_flow' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Gains. Affected line: Modelica.Blocks.Interfaces.RealOutput QIntGains_flow[numZones,3](each final quantity="HeatFlowRate", each final unit="W") if ASurTot > 0 or VAir > 0 "Heat flow based on internal gains for each zone from lights[1], machines[2], and persons[3]" annotation (Placement(transformation(extent={{100,-90},{ 120,-70}}), iconTransformation(extent={{80,-100},{100,-80}}))); \ No newline at end of file diff --git a/docs/PGorzalka_issue1080_ROM-soil-and-zone-borders/regression/ThermalZones/comparison-dymola.log b/docs/PGorzalka_issue1080_ROM-soil-and-zone-borders/regression/ThermalZones/comparison-dymola.log index f5e41c2ed7..9fb28acdbd 100644 --- a/docs/PGorzalka_issue1080_ROM-soil-and-zone-borders/regression/ThermalZones/comparison-dymola.log +++ b/docs/PGorzalka_issue1080_ROM-soil-and-zone-borders/regression/ThermalZones/comparison-dymola.log @@ -105,7 +105,7 @@ }, "model": "AixLib.ThermalZones.HighOrder.Validation.ASHRAE140.Case810", "simulation": { - "elapsed_time": 147, + "elapsed_time": 140, "final_time": 31539600.0, "jacobians": 191551, "start_time": 0, @@ -174,7 +174,7 @@ }, "model": "AixLib.ThermalZones.HighOrder.Validation.ASHRAE140.Case650", "simulation": { - "elapsed_time": 147, + "elapsed_time": 136, "final_time": 31539600.0, "jacobians": 197882, "start_time": 0, @@ -267,7 +267,7 @@ }, "model": "AixLib.ThermalZones.HighOrder.Validation.ASHRAE140.Case395", "simulation": { - "elapsed_time": 52.9, + "elapsed_time": 55.1, "final_time": 31539600.0, "jacobians": 101321, "start_time": 0, @@ -306,7 +306,7 @@ }, "model": "AixLib.ThermalZones.HighOrder.Validation.EmpiricalValidation.TwinHouseN2", "simulation": { - "elapsed_time": 176, + "elapsed_time": 184, "final_time": 3546000.0, "jacobians": 51738, "start_time": 0, @@ -399,7 +399,7 @@ }, "model": "AixLib.ThermalZones.HighOrder.Validation.ASHRAE140.Case320", "simulation": { - "elapsed_time": 167, + "elapsed_time": 180, "final_time": 31539600.0, "jacobians": 225834, "start_time": 0, @@ -438,7 +438,7 @@ }, "model": "AixLib.ThermalZones.ReducedOrder.Examples.MultizoneMoistAirCO2", "simulation": { - "elapsed_time": 37.6196, + "elapsed_time": 35.5994, "final_time": 31536000.0, "jacobians": 11749, "start_time": 0, @@ -477,7 +477,7 @@ }, "model": "AixLib.ThermalZones.ReducedOrder.Examples.ThermalZoneMoistAirSwimmingPool", "simulation": { - "elapsed_time": 44.626, + "elapsed_time": 45.5051, "final_time": 31536000.0, "jacobians": 25950, "start_time": 0, @@ -516,7 +516,7 @@ }, "model": "AixLib.ThermalZones.ReducedOrder.Examples.ThermalZoneMoistAir", "simulation": { - "elapsed_time": 9.89507, + "elapsed_time": 9.19709, "final_time": 31536000.0, "jacobians": 20421, "start_time": 0, @@ -609,7 +609,7 @@ }, "model": "AixLib.ThermalZones.HighOrder.Validation.ASHRAE140.Case210", "simulation": { - "elapsed_time": 85.7, + "elapsed_time": 89.2, "final_time": 31539600.0, "jacobians": 126068, "start_time": 0, @@ -702,7 +702,7 @@ }, "model": "AixLib.ThermalZones.HighOrder.Validation.ASHRAE140.Case900FF", "simulation": { - "elapsed_time": 96.9, + "elapsed_time": 80.7, "final_time": 31539600.0, "jacobians": 123327, "start_time": 0, @@ -795,7 +795,7 @@ }, "model": "AixLib.ThermalZones.HighOrder.Validation.ASHRAE140.Case800", "simulation": { - "elapsed_time": 114, + "elapsed_time": 107, "final_time": 31539600.0, "jacobians": 141517, "start_time": 0, @@ -882,7 +882,7 @@ }, "model": "AixLib.ThermalZones.ReducedOrder.Examples.MultizoneEquipped", "simulation": { - "elapsed_time": 3.87061, + "elapsed_time": 3.68557, "final_time": 864000, "jacobians": 803, "start_time": 0, @@ -975,7 +975,7 @@ }, "model": "AixLib.ThermalZones.HighOrder.Validation.ASHRAE140.Case430", "simulation": { - "elapsed_time": 129, + "elapsed_time": 120, "final_time": 31539600.0, "jacobians": 153601, "start_time": 0, @@ -1062,7 +1062,7 @@ }, "model": "AixLib.ThermalZones.HighOrder.Examples.OFDHeatLoad", "simulation": { - "elapsed_time": 1.6, + "elapsed_time": 1.71, "final_time": 25920000.0, "jacobians": 27, "start_time": 0, @@ -1155,7 +1155,7 @@ }, "model": "AixLib.ThermalZones.HighOrder.Validation.ASHRAE140.Case280", "simulation": { - "elapsed_time": 166, + "elapsed_time": 168, "final_time": 31539600.0, "jacobians": 222040, "start_time": 0, @@ -1206,7 +1206,7 @@ }, "model": "AixLib.ThermalZones.HighOrder.Validation.EmpiricalValidation.Warehouse", "simulation": { - "elapsed_time": 33.6, + "elapsed_time": 29.9, "final_time": 31536000.0, "jacobians": 95719, "start_time": 0, @@ -1320,7 +1320,7 @@ }, "model": "AixLib.ThermalZones.HighOrder.Validation.ASHRAE140.Case250", "simulation": { - "elapsed_time": 90.7, + "elapsed_time": 97.7, "final_time": 31539600.0, "jacobians": 159373, "start_time": 0, @@ -1434,7 +1434,7 @@ }, "model": "AixLib.ThermalZones.HighOrder.Validation.ASHRAE140.Case230", "simulation": { - "elapsed_time": 94, + "elapsed_time": 104, "final_time": 31539600.0, "jacobians": 142453, "start_time": 0, @@ -1479,7 +1479,7 @@ }, "model": "AixLib.ThermalZones.ReducedOrder.Examples.ComparisonThermalZoneMoistAndDryAir", "simulation": { - "elapsed_time": 17.609, + "elapsed_time": 15.9777, "final_time": 31536000.0, "jacobians": 20410, "start_time": 0, @@ -1524,7 +1524,7 @@ }, "model": "AixLib.ThermalZones.ReducedOrder.Examples.ThermalZoneMoistCO2AirExchange", "simulation": { - "elapsed_time": 11.5344, + "elapsed_time": 12.2137, "final_time": 31536000.0, "jacobians": 20815, "start_time": 0, @@ -1617,7 +1617,7 @@ }, "model": "AixLib.ThermalZones.HighOrder.Validation.ASHRAE140.Case600", "simulation": { - "elapsed_time": 201, + "elapsed_time": 196, "final_time": 31539600.0, "jacobians": 230765, "start_time": 0, @@ -1710,7 +1710,7 @@ }, "model": "AixLib.ThermalZones.HighOrder.Validation.ASHRAE140.Case400", "simulation": { - "elapsed_time": 77.6, + "elapsed_time": 69.8, "final_time": 31539600.0, "jacobians": 115951, "start_time": 0, @@ -1761,7 +1761,7 @@ }, "model": "AixLib.ThermalZones.HighOrder.Examples.RoomGFOw2_DayNightMode", "simulation": { - "elapsed_time": 1.27, + "elapsed_time": 1.57, "final_time": 86400, "jacobians": 361, "start_time": 0, @@ -1848,7 +1848,7 @@ }, "model": "AixLib.ThermalZones.ReducedOrder.Examples.MultizonePartlyCooled", "simulation": { - "elapsed_time": 3.01526, + "elapsed_time": 2.40597, "final_time": 15552000.0, "jacobians": 312, "start_time": 14688000.0, @@ -1917,7 +1917,7 @@ }, "model": "AixLib.ThermalZones.HighOrder.Validation.ASHRAE140.Case950", "simulation": { - "elapsed_time": 118, + "elapsed_time": 117, "final_time": 31539600.0, "jacobians": 157652, "start_time": 0, @@ -1950,7 +1950,7 @@ }, "model": "AixLib.ThermalZones.ReducedOrder.Examples.ThermalZoneAirExchange", "simulation": { - "elapsed_time": 15.6981, + "elapsed_time": 14.3784, "final_time": 31536000.0, "jacobians": 20799, "start_time": 0, @@ -2043,7 +2043,7 @@ }, "model": "AixLib.ThermalZones.HighOrder.Validation.ASHRAE140.Case410", "simulation": { - "elapsed_time": 99, + "elapsed_time": 96.8, "final_time": 31539600.0, "jacobians": 125309, "start_time": 0, @@ -2136,7 +2136,7 @@ }, "model": "AixLib.ThermalZones.HighOrder.Validation.ASHRAE140.Case950FF", "simulation": { - "elapsed_time": 70.9, + "elapsed_time": 74.6, "final_time": 31539600.0, "jacobians": 124874, "start_time": 0, @@ -2229,7 +2229,7 @@ }, "model": "AixLib.ThermalZones.HighOrder.Validation.ASHRAE140.Case240", "simulation": { - "elapsed_time": 75.9, + "elapsed_time": 77.8, "final_time": 31539600.0, "jacobians": 125985, "start_time": 0, @@ -2322,7 +2322,7 @@ }, "model": "AixLib.ThermalZones.HighOrder.Validation.ASHRAE140.Case270", "simulation": { - "elapsed_time": 175, + "elapsed_time": 173, "final_time": 31539600.0, "jacobians": 230553, "start_time": 0, @@ -2415,7 +2415,7 @@ }, "model": "AixLib.ThermalZones.HighOrder.Validation.ASHRAE140.Case440", "simulation": { - "elapsed_time": 191, + "elapsed_time": 185, "final_time": 31539600.0, "jacobians": 222204, "start_time": 0, @@ -2508,7 +2508,7 @@ }, "model": "AixLib.ThermalZones.HighOrder.Validation.ASHRAE140.Case220", "simulation": { - "elapsed_time": 78.8, + "elapsed_time": 82.8, "final_time": 31539600.0, "jacobians": 124345, "start_time": 0, @@ -2622,7 +2622,7 @@ }, "model": "AixLib.ThermalZones.HighOrder.Validation.ASHRAE140.Case640", "simulation": { - "elapsed_time": 234, + "elapsed_time": 237, "final_time": 31539600.0, "jacobians": 264096, "start_time": 0, @@ -2715,7 +2715,7 @@ }, "model": "AixLib.ThermalZones.HighOrder.Validation.ASHRAE140.Case940", "simulation": { - "elapsed_time": 155, + "elapsed_time": 150, "final_time": 31539600.0, "jacobians": 216549, "start_time": 0, @@ -2838,7 +2838,7 @@ }, "model": "AixLib.ThermalZones.HighOrder.Examples.ASHREA140.CompareDynamicAndStaticSolarFrac_Case270", "simulation": { - "elapsed_time": 1.45, + "elapsed_time": 1.82, "final_time": 86400, "jacobians": 1001, "start_time": 0, @@ -2931,7 +2931,7 @@ }, "model": "AixLib.ThermalZones.HighOrder.Validation.ASHRAE140.Case650FF", "simulation": { - "elapsed_time": 103, + "elapsed_time": 108, "final_time": 31539600.0, "jacobians": 140274, "start_time": 0, @@ -2964,7 +2964,7 @@ }, "model": "AixLib.ThermalZones.ReducedOrder.Examples.ThermalZone", "simulation": { - "elapsed_time": 17.7942, + "elapsed_time": 15.2129, "final_time": 31536000.0, "jacobians": 20407, "start_time": 0, @@ -3027,7 +3027,7 @@ }, "model": "AixLib.ThermalZones.ReducedOrder.Examples.Multizone", "simulation": { - "elapsed_time": 1.76448, + "elapsed_time": 1.42475, "final_time": 864000, "jacobians": 325, "start_time": 0, @@ -3141,7 +3141,7 @@ }, "model": "AixLib.ThermalZones.HighOrder.Validation.ASHRAE140.Case900", "simulation": { - "elapsed_time": 171, + "elapsed_time": 170, "final_time": 31539600.0, "jacobians": 204912, "start_time": 0, @@ -3234,7 +3234,7 @@ }, "model": "AixLib.ThermalZones.HighOrder.Validation.ASHRAE140.Case420", "simulation": { - "elapsed_time": 79.3, + "elapsed_time": 81.4, "final_time": 31539600.0, "jacobians": 126055, "start_time": 0, @@ -3321,7 +3321,7 @@ }, "model": "AixLib.ThermalZones.ReducedOrder.Examples.MultizoneMoistAirCO2Equipped", "simulation": { - "elapsed_time": 6.9744, + "elapsed_time": 5.80394, "final_time": 864000, "jacobians": 787, "start_time": 0, @@ -3414,7 +3414,7 @@ }, "model": "AixLib.ThermalZones.HighOrder.Validation.ASHRAE140.Case600FF", "simulation": { - "elapsed_time": 69.5, + "elapsed_time": 72.8, "final_time": 31539600.0, "jacobians": 143407, "start_time": 0, diff --git a/docs/PGorzalka_issue1080_ROM-soil-and-zone-borders/regression/ThermalZones/simulator-dymola.log b/docs/PGorzalka_issue1080_ROM-soil-and-zone-borders/regression/ThermalZones/simulator-dymola.log index 60e517605a..89c77ee439 100644 --- a/docs/PGorzalka_issue1080_ROM-soil-and-zone-borders/regression/ThermalZones/simulator-dymola.log +++ b/docs/PGorzalka_issue1080_ROM-soil-and-zone-borders/regression/ThermalZones/simulator-dymola.log @@ -1312,92 +1312,92 @@ rCheck = checkModel("AixLib.ThermalZones.HighOrder.Examples.OFDHeatLoad"); Check of AixLib.ThermalZones.HighOrder.Examples.OFDHeatLoad Warning: Base class Medium is not transitively non-replaceable, since it is a short class equal to a replaceable class. - File: /tmp/tmp-AixLib-1-egefhjuo/AixLib/ThermalZones/HighOrder/House/OFD_MiddleInnerLoadWall/BuildingEnvelope/WholeHouseBuildingEnvelope.mo, line 193 + File: /tmp/tmp-AixLib-1-anklca82/AixLib/ThermalZones/HighOrder/House/OFD_MiddleInnerLoadWall/BuildingEnvelope/WholeHouseBuildingEnvelope.mo, line 193 Component context: AixLib.ThermalZones.HighOrder.House.OFD_MiddleInnerLoadWall.BuildingEnvelope.WholeHouseBuildingEnvelope.Medium Component declared as Attic_Ro2Lf5 attic_2Ro_5Rooms in AixLib.ThermalZones.HighOrder.House.OFD_MiddleInnerLoadWall.BuildingEnvelope.WholeHouseBuildingEnvelope Warning: Base class Medium is not transitively non-replaceable, since it is a short class equal to a replaceable class. - File: /tmp/tmp-AixLib-1-egefhjuo/AixLib/ThermalZones/HighOrder/House/OFD_MiddleInnerLoadWall/BuildingEnvelope/WholeHouseBuildingEnvelope.mo, line 193 + File: /tmp/tmp-AixLib-1-anklca82/AixLib/ThermalZones/HighOrder/House/OFD_MiddleInnerLoadWall/BuildingEnvelope/WholeHouseBuildingEnvelope.mo, line 193 Component context: AixLib.ThermalZones.HighOrder.House.OFD_MiddleInnerLoadWall.BuildingEnvelope.WholeHouseBuildingEnvelope.Medium Component declared as MixingVolumeMoistAir airload in AixLib.ThermalZones.HighOrder.Rooms.BaseClasses.PartialRoom Warning: Base class Medium is not transitively non-replaceable, since it is a short class equal to a replaceable class. - File: /tmp/tmp-AixLib-1-egefhjuo/AixLib/ThermalZones/HighOrder/House/OFD_MiddleInnerLoadWall/BuildingEnvelope/WholeHouseBuildingEnvelope.mo, line 193 + File: /tmp/tmp-AixLib-1-anklca82/AixLib/ThermalZones/HighOrder/House/OFD_MiddleInnerLoadWall/BuildingEnvelope/WholeHouseBuildingEnvelope.mo, line 193 Component context: AixLib.ThermalZones.HighOrder.House.OFD_MiddleInnerLoadWall.BuildingEnvelope.WholeHouseBuildingEnvelope.Medium Component declared as VesselFluidPorts_b ports in AixLib.Fluid.MixingVolumes.BaseClasses.PartialMixingVolume Warning: Base class Medium is not transitively non-replaceable, since it is a short class equal to a replaceable class. - File: /tmp/tmp-AixLib-1-egefhjuo/AixLib/ThermalZones/HighOrder/House/OFD_MiddleInnerLoadWall/BuildingEnvelope/WholeHouseBuildingEnvelope.mo, line 193 + File: /tmp/tmp-AixLib-1-anklca82/AixLib/ThermalZones/HighOrder/House/OFD_MiddleInnerLoadWall/BuildingEnvelope/WholeHouseBuildingEnvelope.mo, line 193 Component context: AixLib.ThermalZones.HighOrder.House.OFD_MiddleInnerLoadWall.BuildingEnvelope.WholeHouseBuildingEnvelope.Medium Component declared as VesselFluidPorts_b ports in AixLib.Fluid.MixingVolumes.BaseClasses.PartialMixingVolume Warning: Base class Medium is not transitively non-replaceable, since it is a short class equal to a replaceable class. - File: /tmp/tmp-AixLib-1-egefhjuo/AixLib/ThermalZones/HighOrder/House/OFD_MiddleInnerLoadWall/BuildingEnvelope/WholeHouseBuildingEnvelope.mo, line 193 + File: /tmp/tmp-AixLib-1-anklca82/AixLib/ThermalZones/HighOrder/House/OFD_MiddleInnerLoadWall/BuildingEnvelope/WholeHouseBuildingEnvelope.mo, line 193 Component context: AixLib.ThermalZones.HighOrder.House.OFD_MiddleInnerLoadWall.BuildingEnvelope.WholeHouseBuildingEnvelope.Medium Component declared as FluidPort_a port_a in AixLib.Fluid.Interfaces.PartialTwoPort Warning: Base class Medium is not transitively non-replaceable, since it is a short class equal to a replaceable class. - File: /tmp/tmp-AixLib-1-egefhjuo/AixLib/ThermalZones/HighOrder/House/OFD_MiddleInnerLoadWall/BuildingEnvelope/WholeHouseBuildingEnvelope.mo, line 193 + File: /tmp/tmp-AixLib-1-anklca82/AixLib/ThermalZones/HighOrder/House/OFD_MiddleInnerLoadWall/BuildingEnvelope/WholeHouseBuildingEnvelope.mo, line 193 Component context: AixLib.ThermalZones.HighOrder.House.OFD_MiddleInnerLoadWall.BuildingEnvelope.WholeHouseBuildingEnvelope.Medium Component declared as FluidPort_a port_a in AixLib.Fluid.Interfaces.PartialTwoPort Warning: Base class Medium is not transitively non-replaceable, since it is a short class equal to a replaceable class. - File: /tmp/tmp-AixLib-1-egefhjuo/AixLib/ThermalZones/HighOrder/House/OFD_MiddleInnerLoadWall/BuildingEnvelope/WholeHouseBuildingEnvelope.mo, line 193 + File: /tmp/tmp-AixLib-1-anklca82/AixLib/ThermalZones/HighOrder/House/OFD_MiddleInnerLoadWall/BuildingEnvelope/WholeHouseBuildingEnvelope.mo, line 193 Component context: AixLib.ThermalZones.HighOrder.House.OFD_MiddleInnerLoadWall.BuildingEnvelope.WholeHouseBuildingEnvelope.Medium Component declared as FluidPort_b port_b in AixLib.Fluid.Interfaces.PartialTwoPort Warning: Base class Medium is not transitively non-replaceable, since it is a short class equal to a replaceable class. - File: /tmp/tmp-AixLib-1-egefhjuo/AixLib/ThermalZones/HighOrder/House/OFD_MiddleInnerLoadWall/BuildingEnvelope/WholeHouseBuildingEnvelope.mo, line 193 + File: /tmp/tmp-AixLib-1-anklca82/AixLib/ThermalZones/HighOrder/House/OFD_MiddleInnerLoadWall/BuildingEnvelope/WholeHouseBuildingEnvelope.mo, line 193 Component context: AixLib.ThermalZones.HighOrder.House.OFD_MiddleInnerLoadWall.BuildingEnvelope.WholeHouseBuildingEnvelope.Medium Component declared as FluidPort_b port_b in AixLib.Fluid.Interfaces.PartialTwoPort Warning: Base class Medium is not transitively non-replaceable, since it is a short class equal to a replaceable class. - File: /tmp/tmp-AixLib-1-egefhjuo/AixLib/ThermalZones/HighOrder/House/OFD_MiddleInnerLoadWall/BuildingEnvelope/WholeHouseBuildingEnvelope.mo, line 193 + File: /tmp/tmp-AixLib-1-anklca82/AixLib/ThermalZones/HighOrder/House/OFD_MiddleInnerLoadWall/BuildingEnvelope/WholeHouseBuildingEnvelope.mo, line 193 Component context: AixLib.ThermalZones.HighOrder.House.OFD_MiddleInnerLoadWall.BuildingEnvelope.WholeHouseBuildingEnvelope.Medium Component declared as StaticTwoPortConservationEquation steBal in AixLib.Fluid.MixingVolumes.BaseClasses.PartialMixingVolume Warning: Base class Medium is not transitively non-replaceable, since it is a short class equal to a replaceable class. - File: /tmp/tmp-AixLib-1-egefhjuo/AixLib/ThermalZones/HighOrder/House/OFD_MiddleInnerLoadWall/BuildingEnvelope/WholeHouseBuildingEnvelope.mo, line 193 + File: /tmp/tmp-AixLib-1-anklca82/AixLib/ThermalZones/HighOrder/House/OFD_MiddleInnerLoadWall/BuildingEnvelope/WholeHouseBuildingEnvelope.mo, line 193 Component context: AixLib.ThermalZones.HighOrder.House.OFD_MiddleInnerLoadWall.BuildingEnvelope.WholeHouseBuildingEnvelope.Medium Component declared as StaticTwoPortConservationEquation steBal in AixLib.Fluid.MixingVolumes.BaseClasses.PartialMixingVolume Warning: Base class Medium is not transitively non-replaceable, since it is a short class equal to a replaceable class. - File: /tmp/tmp-AixLib-1-egefhjuo/AixLib/ThermalZones/HighOrder/House/OFD_MiddleInnerLoadWall/BuildingEnvelope/WholeHouseBuildingEnvelope.mo, line 193 + File: /tmp/tmp-AixLib-1-anklca82/AixLib/ThermalZones/HighOrder/House/OFD_MiddleInnerLoadWall/BuildingEnvelope/WholeHouseBuildingEnvelope.mo, line 193 Component context: AixLib.ThermalZones.HighOrder.House.OFD_MiddleInnerLoadWall.BuildingEnvelope.WholeHouseBuildingEnvelope.Medium Component declared as ConservationEquation dynBal in AixLib.Fluid.MixingVolumes.BaseClasses.PartialMixingVolume Warning: Base class Medium is not transitively non-replaceable, since it is a short class equal to a replaceable class. - File: /tmp/tmp-AixLib-1-egefhjuo/AixLib/ThermalZones/HighOrder/House/OFD_MiddleInnerLoadWall/BuildingEnvelope/WholeHouseBuildingEnvelope.mo, line 193 + File: /tmp/tmp-AixLib-1-anklca82/AixLib/ThermalZones/HighOrder/House/OFD_MiddleInnerLoadWall/BuildingEnvelope/WholeHouseBuildingEnvelope.mo, line 193 Component context: AixLib.ThermalZones.HighOrder.House.OFD_MiddleInnerLoadWall.BuildingEnvelope.WholeHouseBuildingEnvelope.Medium Component declared as VesselFluidPorts_b ports in AixLib.Fluid.Interfaces.ConservationEquation Warning: Base class Medium is not transitively non-replaceable, since it is a short class equal to a replaceable class. - File: /tmp/tmp-AixLib-1-egefhjuo/AixLib/ThermalZones/HighOrder/House/OFD_MiddleInnerLoadWall/BuildingEnvelope/WholeHouseBuildingEnvelope.mo, line 193 + File: /tmp/tmp-AixLib-1-anklca82/AixLib/ThermalZones/HighOrder/House/OFD_MiddleInnerLoadWall/BuildingEnvelope/WholeHouseBuildingEnvelope.mo, line 193 Component context: AixLib.ThermalZones.HighOrder.House.OFD_MiddleInnerLoadWall.BuildingEnvelope.WholeHouseBuildingEnvelope.Medium Component declared as VesselFluidPorts_b ports in AixLib.Fluid.Interfaces.ConservationEquation Warning: Base class Medium is not transitively non-replaceable, since it is a short class equal to a replaceable class. - File: /tmp/tmp-AixLib-1-egefhjuo/AixLib/ThermalZones/HighOrder/House/OFD_MiddleInnerLoadWall/BuildingEnvelope/WholeHouseBuildingEnvelope.mo, line 193 + File: /tmp/tmp-AixLib-1-anklca82/AixLib/ThermalZones/HighOrder/House/OFD_MiddleInnerLoadWall/BuildingEnvelope/WholeHouseBuildingEnvelope.mo, line 193 Component context: AixLib.ThermalZones.HighOrder.House.OFD_MiddleInnerLoadWall.BuildingEnvelope.WholeHouseBuildingEnvelope.Medium Component declared as ConservationEquation dynBal in AixLib.Fluid.MixingVolumes.BaseClasses.PartialMixingVolume Warning: Base class Medium is not transitively non-replaceable, since it is a short class equal to a replaceable class. - File: /tmp/tmp-AixLib-1-egefhjuo/AixLib/ThermalZones/HighOrder/House/OFD_MiddleInnerLoadWall/BuildingEnvelope/WholeHouseBuildingEnvelope.mo, line 193 + File: /tmp/tmp-AixLib-1-anklca82/AixLib/ThermalZones/HighOrder/House/OFD_MiddleInnerLoadWall/BuildingEnvelope/WholeHouseBuildingEnvelope.mo, line 193 Component context: AixLib.ThermalZones.HighOrder.House.OFD_MiddleInnerLoadWall.BuildingEnvelope.WholeHouseBuildingEnvelope.Medium Component declared as MixingVolumeMoistAir airload in AixLib.ThermalZones.HighOrder.Rooms.BaseClasses.PartialRoom Warning: Base class Medium is not transitively non-replaceable, since it is a short class equal to a replaceable class. - File: /tmp/tmp-AixLib-1-egefhjuo/AixLib/ThermalZones/HighOrder/House/OFD_MiddleInnerLoadWall/BuildingEnvelope/WholeHouseBuildingEnvelope.mo, line 193 + File: /tmp/tmp-AixLib-1-anklca82/AixLib/ThermalZones/HighOrder/House/OFD_MiddleInnerLoadWall/BuildingEnvelope/WholeHouseBuildingEnvelope.mo, line 193 Component context: AixLib.ThermalZones.HighOrder.House.OFD_MiddleInnerLoadWall.BuildingEnvelope.WholeHouseBuildingEnvelope.Medium Component declared as VesselFluidPorts_b ports in AixLib.ThermalZones.HighOrder.Rooms.BaseClasses.PartialRoom Warning: Base class Medium is not transitively non-replaceable, since it is a short class equal to a replaceable class. - File: /tmp/tmp-AixLib-1-egefhjuo/AixLib/ThermalZones/HighOrder/House/OFD_MiddleInnerLoadWall/BuildingEnvelope/WholeHouseBuildingEnvelope.mo, line 193 + File: /tmp/tmp-AixLib-1-anklca82/AixLib/ThermalZones/HighOrder/House/OFD_MiddleInnerLoadWall/BuildingEnvelope/WholeHouseBuildingEnvelope.mo, line 193 Component context: AixLib.ThermalZones.HighOrder.House.OFD_MiddleInnerLoadWall.BuildingEnvelope.WholeHouseBuildingEnvelope.Medium Component declared as VesselFluidPorts_b ports in AixLib.ThermalZones.HighOrder.Rooms.BaseClasses.PartialRoom Warning: Base class Medium is not transitively non-replaceable, since it is a short class equal to a replaceable class. - File: /tmp/tmp-AixLib-1-egefhjuo/AixLib/ThermalZones/HighOrder/House/OFD_MiddleInnerLoadWall/BuildingEnvelope/WholeHouseBuildingEnvelope.mo, line 193 + File: /tmp/tmp-AixLib-1-anklca82/AixLib/ThermalZones/HighOrder/House/OFD_MiddleInnerLoadWall/BuildingEnvelope/WholeHouseBuildingEnvelope.mo, line 193 Context: AixLib.ThermalZones.HighOrder.House.OFD_MiddleInnerLoadWall.BuildingEnvelope.WholeHouseBuildingEnvelope.Medium Warning: Inconsistency for connectors dimensioned using parameter with annotation(Dialog(connectorSizing=true)). Some connector elements are not connected. @@ -1432,92 +1432,92 @@ simulateModel("AixLib.ThermalZones.HighOrder.Examples.OFDHeatLoad", startTime=0, Translation of AixLib.ThermalZones.HighOrder.Examples.OFDHeatLoad Warning: Base class Medium is not transitively non-replaceable, since it is a short class equal to a replaceable class. - File: /tmp/tmp-AixLib-1-egefhjuo/AixLib/ThermalZones/HighOrder/House/OFD_MiddleInnerLoadWall/BuildingEnvelope/WholeHouseBuildingEnvelope.mo, line 193 + File: /tmp/tmp-AixLib-1-anklca82/AixLib/ThermalZones/HighOrder/House/OFD_MiddleInnerLoadWall/BuildingEnvelope/WholeHouseBuildingEnvelope.mo, line 193 Component context: AixLib.ThermalZones.HighOrder.House.OFD_MiddleInnerLoadWall.BuildingEnvelope.WholeHouseBuildingEnvelope.Medium Component declared as Attic_Ro2Lf5 attic_2Ro_5Rooms in AixLib.ThermalZones.HighOrder.House.OFD_MiddleInnerLoadWall.BuildingEnvelope.WholeHouseBuildingEnvelope Warning: Base class Medium is not transitively non-replaceable, since it is a short class equal to a replaceable class. - File: /tmp/tmp-AixLib-1-egefhjuo/AixLib/ThermalZones/HighOrder/House/OFD_MiddleInnerLoadWall/BuildingEnvelope/WholeHouseBuildingEnvelope.mo, line 193 + File: /tmp/tmp-AixLib-1-anklca82/AixLib/ThermalZones/HighOrder/House/OFD_MiddleInnerLoadWall/BuildingEnvelope/WholeHouseBuildingEnvelope.mo, line 193 Component context: AixLib.ThermalZones.HighOrder.House.OFD_MiddleInnerLoadWall.BuildingEnvelope.WholeHouseBuildingEnvelope.Medium Component declared as MixingVolumeMoistAir airload in AixLib.ThermalZones.HighOrder.Rooms.BaseClasses.PartialRoom Warning: Base class Medium is not transitively non-replaceable, since it is a short class equal to a replaceable class. - File: /tmp/tmp-AixLib-1-egefhjuo/AixLib/ThermalZones/HighOrder/House/OFD_MiddleInnerLoadWall/BuildingEnvelope/WholeHouseBuildingEnvelope.mo, line 193 + File: /tmp/tmp-AixLib-1-anklca82/AixLib/ThermalZones/HighOrder/House/OFD_MiddleInnerLoadWall/BuildingEnvelope/WholeHouseBuildingEnvelope.mo, line 193 Component context: AixLib.ThermalZones.HighOrder.House.OFD_MiddleInnerLoadWall.BuildingEnvelope.WholeHouseBuildingEnvelope.Medium Component declared as VesselFluidPorts_b ports in AixLib.Fluid.MixingVolumes.BaseClasses.PartialMixingVolume Warning: Base class Medium is not transitively non-replaceable, since it is a short class equal to a replaceable class. - File: /tmp/tmp-AixLib-1-egefhjuo/AixLib/ThermalZones/HighOrder/House/OFD_MiddleInnerLoadWall/BuildingEnvelope/WholeHouseBuildingEnvelope.mo, line 193 + File: /tmp/tmp-AixLib-1-anklca82/AixLib/ThermalZones/HighOrder/House/OFD_MiddleInnerLoadWall/BuildingEnvelope/WholeHouseBuildingEnvelope.mo, line 193 Component context: AixLib.ThermalZones.HighOrder.House.OFD_MiddleInnerLoadWall.BuildingEnvelope.WholeHouseBuildingEnvelope.Medium Component declared as VesselFluidPorts_b ports in AixLib.Fluid.MixingVolumes.BaseClasses.PartialMixingVolume Warning: Base class Medium is not transitively non-replaceable, since it is a short class equal to a replaceable class. - File: /tmp/tmp-AixLib-1-egefhjuo/AixLib/ThermalZones/HighOrder/House/OFD_MiddleInnerLoadWall/BuildingEnvelope/WholeHouseBuildingEnvelope.mo, line 193 + File: /tmp/tmp-AixLib-1-anklca82/AixLib/ThermalZones/HighOrder/House/OFD_MiddleInnerLoadWall/BuildingEnvelope/WholeHouseBuildingEnvelope.mo, line 193 Component context: AixLib.ThermalZones.HighOrder.House.OFD_MiddleInnerLoadWall.BuildingEnvelope.WholeHouseBuildingEnvelope.Medium Component declared as FluidPort_a port_a in AixLib.Fluid.Interfaces.PartialTwoPort Warning: Base class Medium is not transitively non-replaceable, since it is a short class equal to a replaceable class. - File: /tmp/tmp-AixLib-1-egefhjuo/AixLib/ThermalZones/HighOrder/House/OFD_MiddleInnerLoadWall/BuildingEnvelope/WholeHouseBuildingEnvelope.mo, line 193 + File: /tmp/tmp-AixLib-1-anklca82/AixLib/ThermalZones/HighOrder/House/OFD_MiddleInnerLoadWall/BuildingEnvelope/WholeHouseBuildingEnvelope.mo, line 193 Component context: AixLib.ThermalZones.HighOrder.House.OFD_MiddleInnerLoadWall.BuildingEnvelope.WholeHouseBuildingEnvelope.Medium Component declared as FluidPort_a port_a in AixLib.Fluid.Interfaces.PartialTwoPort Warning: Base class Medium is not transitively non-replaceable, since it is a short class equal to a replaceable class. - File: /tmp/tmp-AixLib-1-egefhjuo/AixLib/ThermalZones/HighOrder/House/OFD_MiddleInnerLoadWall/BuildingEnvelope/WholeHouseBuildingEnvelope.mo, line 193 + File: /tmp/tmp-AixLib-1-anklca82/AixLib/ThermalZones/HighOrder/House/OFD_MiddleInnerLoadWall/BuildingEnvelope/WholeHouseBuildingEnvelope.mo, line 193 Component context: AixLib.ThermalZones.HighOrder.House.OFD_MiddleInnerLoadWall.BuildingEnvelope.WholeHouseBuildingEnvelope.Medium Component declared as FluidPort_b port_b in AixLib.Fluid.Interfaces.PartialTwoPort Warning: Base class Medium is not transitively non-replaceable, since it is a short class equal to a replaceable class. - File: /tmp/tmp-AixLib-1-egefhjuo/AixLib/ThermalZones/HighOrder/House/OFD_MiddleInnerLoadWall/BuildingEnvelope/WholeHouseBuildingEnvelope.mo, line 193 + File: /tmp/tmp-AixLib-1-anklca82/AixLib/ThermalZones/HighOrder/House/OFD_MiddleInnerLoadWall/BuildingEnvelope/WholeHouseBuildingEnvelope.mo, line 193 Component context: AixLib.ThermalZones.HighOrder.House.OFD_MiddleInnerLoadWall.BuildingEnvelope.WholeHouseBuildingEnvelope.Medium Component declared as FluidPort_b port_b in AixLib.Fluid.Interfaces.PartialTwoPort Warning: Base class Medium is not transitively non-replaceable, since it is a short class equal to a replaceable class. - File: /tmp/tmp-AixLib-1-egefhjuo/AixLib/ThermalZones/HighOrder/House/OFD_MiddleInnerLoadWall/BuildingEnvelope/WholeHouseBuildingEnvelope.mo, line 193 + File: /tmp/tmp-AixLib-1-anklca82/AixLib/ThermalZones/HighOrder/House/OFD_MiddleInnerLoadWall/BuildingEnvelope/WholeHouseBuildingEnvelope.mo, line 193 Component context: AixLib.ThermalZones.HighOrder.House.OFD_MiddleInnerLoadWall.BuildingEnvelope.WholeHouseBuildingEnvelope.Medium Component declared as StaticTwoPortConservationEquation steBal in AixLib.Fluid.MixingVolumes.BaseClasses.PartialMixingVolume Warning: Base class Medium is not transitively non-replaceable, since it is a short class equal to a replaceable class. - File: /tmp/tmp-AixLib-1-egefhjuo/AixLib/ThermalZones/HighOrder/House/OFD_MiddleInnerLoadWall/BuildingEnvelope/WholeHouseBuildingEnvelope.mo, line 193 + File: /tmp/tmp-AixLib-1-anklca82/AixLib/ThermalZones/HighOrder/House/OFD_MiddleInnerLoadWall/BuildingEnvelope/WholeHouseBuildingEnvelope.mo, line 193 Component context: AixLib.ThermalZones.HighOrder.House.OFD_MiddleInnerLoadWall.BuildingEnvelope.WholeHouseBuildingEnvelope.Medium Component declared as StaticTwoPortConservationEquation steBal in AixLib.Fluid.MixingVolumes.BaseClasses.PartialMixingVolume Warning: Base class Medium is not transitively non-replaceable, since it is a short class equal to a replaceable class. - File: /tmp/tmp-AixLib-1-egefhjuo/AixLib/ThermalZones/HighOrder/House/OFD_MiddleInnerLoadWall/BuildingEnvelope/WholeHouseBuildingEnvelope.mo, line 193 + File: /tmp/tmp-AixLib-1-anklca82/AixLib/ThermalZones/HighOrder/House/OFD_MiddleInnerLoadWall/BuildingEnvelope/WholeHouseBuildingEnvelope.mo, line 193 Component context: AixLib.ThermalZones.HighOrder.House.OFD_MiddleInnerLoadWall.BuildingEnvelope.WholeHouseBuildingEnvelope.Medium Component declared as ConservationEquation dynBal in AixLib.Fluid.MixingVolumes.BaseClasses.PartialMixingVolume Warning: Base class Medium is not transitively non-replaceable, since it is a short class equal to a replaceable class. - File: /tmp/tmp-AixLib-1-egefhjuo/AixLib/ThermalZones/HighOrder/House/OFD_MiddleInnerLoadWall/BuildingEnvelope/WholeHouseBuildingEnvelope.mo, line 193 + File: /tmp/tmp-AixLib-1-anklca82/AixLib/ThermalZones/HighOrder/House/OFD_MiddleInnerLoadWall/BuildingEnvelope/WholeHouseBuildingEnvelope.mo, line 193 Component context: AixLib.ThermalZones.HighOrder.House.OFD_MiddleInnerLoadWall.BuildingEnvelope.WholeHouseBuildingEnvelope.Medium Component declared as VesselFluidPorts_b ports in AixLib.Fluid.Interfaces.ConservationEquation Warning: Base class Medium is not transitively non-replaceable, since it is a short class equal to a replaceable class. - File: /tmp/tmp-AixLib-1-egefhjuo/AixLib/ThermalZones/HighOrder/House/OFD_MiddleInnerLoadWall/BuildingEnvelope/WholeHouseBuildingEnvelope.mo, line 193 + File: /tmp/tmp-AixLib-1-anklca82/AixLib/ThermalZones/HighOrder/House/OFD_MiddleInnerLoadWall/BuildingEnvelope/WholeHouseBuildingEnvelope.mo, line 193 Component context: AixLib.ThermalZones.HighOrder.House.OFD_MiddleInnerLoadWall.BuildingEnvelope.WholeHouseBuildingEnvelope.Medium Component declared as VesselFluidPorts_b ports in AixLib.Fluid.Interfaces.ConservationEquation Warning: Base class Medium is not transitively non-replaceable, since it is a short class equal to a replaceable class. - File: /tmp/tmp-AixLib-1-egefhjuo/AixLib/ThermalZones/HighOrder/House/OFD_MiddleInnerLoadWall/BuildingEnvelope/WholeHouseBuildingEnvelope.mo, line 193 + File: /tmp/tmp-AixLib-1-anklca82/AixLib/ThermalZones/HighOrder/House/OFD_MiddleInnerLoadWall/BuildingEnvelope/WholeHouseBuildingEnvelope.mo, line 193 Component context: AixLib.ThermalZones.HighOrder.House.OFD_MiddleInnerLoadWall.BuildingEnvelope.WholeHouseBuildingEnvelope.Medium Component declared as ConservationEquation dynBal in AixLib.Fluid.MixingVolumes.BaseClasses.PartialMixingVolume Warning: Base class Medium is not transitively non-replaceable, since it is a short class equal to a replaceable class. - File: /tmp/tmp-AixLib-1-egefhjuo/AixLib/ThermalZones/HighOrder/House/OFD_MiddleInnerLoadWall/BuildingEnvelope/WholeHouseBuildingEnvelope.mo, line 193 + File: /tmp/tmp-AixLib-1-anklca82/AixLib/ThermalZones/HighOrder/House/OFD_MiddleInnerLoadWall/BuildingEnvelope/WholeHouseBuildingEnvelope.mo, line 193 Component context: AixLib.ThermalZones.HighOrder.House.OFD_MiddleInnerLoadWall.BuildingEnvelope.WholeHouseBuildingEnvelope.Medium Component declared as MixingVolumeMoistAir airload in AixLib.ThermalZones.HighOrder.Rooms.BaseClasses.PartialRoom Warning: Base class Medium is not transitively non-replaceable, since it is a short class equal to a replaceable class. - File: /tmp/tmp-AixLib-1-egefhjuo/AixLib/ThermalZones/HighOrder/House/OFD_MiddleInnerLoadWall/BuildingEnvelope/WholeHouseBuildingEnvelope.mo, line 193 + File: /tmp/tmp-AixLib-1-anklca82/AixLib/ThermalZones/HighOrder/House/OFD_MiddleInnerLoadWall/BuildingEnvelope/WholeHouseBuildingEnvelope.mo, line 193 Component context: AixLib.ThermalZones.HighOrder.House.OFD_MiddleInnerLoadWall.BuildingEnvelope.WholeHouseBuildingEnvelope.Medium Component declared as VesselFluidPorts_b ports in AixLib.ThermalZones.HighOrder.Rooms.BaseClasses.PartialRoom Warning: Base class Medium is not transitively non-replaceable, since it is a short class equal to a replaceable class. - File: /tmp/tmp-AixLib-1-egefhjuo/AixLib/ThermalZones/HighOrder/House/OFD_MiddleInnerLoadWall/BuildingEnvelope/WholeHouseBuildingEnvelope.mo, line 193 + File: /tmp/tmp-AixLib-1-anklca82/AixLib/ThermalZones/HighOrder/House/OFD_MiddleInnerLoadWall/BuildingEnvelope/WholeHouseBuildingEnvelope.mo, line 193 Component context: AixLib.ThermalZones.HighOrder.House.OFD_MiddleInnerLoadWall.BuildingEnvelope.WholeHouseBuildingEnvelope.Medium Component declared as VesselFluidPorts_b ports in AixLib.ThermalZones.HighOrder.Rooms.BaseClasses.PartialRoom Warning: Base class Medium is not transitively non-replaceable, since it is a short class equal to a replaceable class. - File: /tmp/tmp-AixLib-1-egefhjuo/AixLib/ThermalZones/HighOrder/House/OFD_MiddleInnerLoadWall/BuildingEnvelope/WholeHouseBuildingEnvelope.mo, line 193 + File: /tmp/tmp-AixLib-1-anklca82/AixLib/ThermalZones/HighOrder/House/OFD_MiddleInnerLoadWall/BuildingEnvelope/WholeHouseBuildingEnvelope.mo, line 193 Context: AixLib.ThermalZones.HighOrder.House.OFD_MiddleInnerLoadWall.BuildingEnvelope.WholeHouseBuildingEnvelope.Medium Warning: Inconsistency for connectors dimensioned using parameter with annotation(Dialog(connectorSizing=true)). Some connector elements are not connected. @@ -2744,7 +2744,7 @@ savelog("AixLib.ThermalZones.ReducedOrder.Examples.MultizonePartlyCooled.transla rCheck = checkModel("AixLib.ThermalZones.HighOrder.Examples.RoomGFOw2_DayNightMode"); Check of AixLib.ThermalZones.HighOrder.Examples.RoomGFOw2_DayNightMode Warning: Component type specifier Pump specified an obsolete type: Obsolete model - Use one of the valves in package AixLib.Fluid.Movers.. - File: /tmp/tmp-AixLib-2-fabo3vhk/AixLib/ThermalZones/HighOrder/Examples/RoomGFOw2_DayNightMode.mo, line 50 + File: /tmp/tmp-AixLib-2-bvjzroyl/AixLib/ThermalZones/HighOrder/Examples/RoomGFOw2_DayNightMode.mo, line 50 Component context: Pump Component declared as Pump Pump in AixLib.Obsolete.Year2021.Fluid.Movers The model has the same number of unknowns and equations: 2610 @@ -2771,7 +2771,7 @@ rScript=RunScript("modelica://AixLib/Resources/Scripts/Dymola/ThermalZones/HighO simulateModel("AixLib.ThermalZones.HighOrder.Examples.RoomGFOw2_DayNightMode", startTime=0, stopTime=86400, outputInterval=60, tolerance=1e-6, method="dassl", resultFile="AixLib.ThermalZones.HighOrder.Examples.RoomGFOw2_DayNightMode"); Translation of AixLib.ThermalZones.HighOrder.Examples.RoomGFOw2_DayNightMode Warning: Component type specifier Pump specified an obsolete type: Obsolete model - Use one of the valves in package AixLib.Fluid.Movers.. - File: /tmp/tmp-AixLib-2-fabo3vhk/AixLib/ThermalZones/HighOrder/Examples/RoomGFOw2_DayNightMode.mo, line 50 + File: /tmp/tmp-AixLib-2-bvjzroyl/AixLib/ThermalZones/HighOrder/Examples/RoomGFOw2_DayNightMode.mo, line 50 Component context: Pump Component declared as Pump Pump in AixLib.Obsolete.Year2021.Fluid.Movers The DAE has 2610 scalar unknowns and 2610 scalar equations. @@ -4179,7 +4179,6 @@ Room.wallWest.Wall.simpleNLayer.cap[1].T Room.wallWest.Wall.simpleNLayer.cap[2].T Room.wallWest.Wall.simpleNLayer.cap[3].T Finished -Not possible to open file "AixLib.ThermalZones.HighOrder.Validation.ASHRAE140.Case640.mat": No such file or directory Finished = true