Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

Measurement immediately stops in Single Trigger mode without event #273

Open
abusse opened this issue Oct 18, 2018 · 6 comments
Open

Measurement immediately stops in Single Trigger mode without event #273

abusse opened this issue Oct 18, 2018 · 6 comments

Comments

@abusse
Copy link

abusse commented Oct 18, 2018

Hi everyone,

I just built Openhantek from the latest commit and have in issue with the trigger in single mode. Instead of stopping at a rising or falling edge, the measurement stops almost immediately without the measurement getting anywhere close to the set trigger value. I'm using a 6022BL, if this is important.

@StephanRichter
Copy link

StephanRichter commented Oct 25, 2018

Today my Device has arrived. I Built the sources and played around. And I can confirm this observation.

Linux Mint 19 / Kernel 4.15.0-43-generic (64bit)

@matthiesenj
Copy link

I also have this problem.. Pressing the play button, it momentarily shows the pause icon (||), then immediately returns to showing the play (|>) icon. OpenHantek 30.09.2018_na on windows 10 64 bit.

@abc123me
Copy link

abc123me commented Jan 5, 2019

Same issue here on linux with a Hantek 6022BE

@Zbysekz
Copy link

Zbysekz commented Jan 5, 2019

Same issue here, ubuntu 18, Hantek6022BL

@claus007
Copy link

Same issue here, Hantek6022BL
Is there still development going on ?

@Ho-Ro
Copy link
Member

Ho-Ro commented Sep 17, 2020

Please read #277

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment
Labels
None yet
Projects
None yet
Development

No branches or pull requests

7 participants