From 1e2103a8e7fbb7ffd92572523dbcf1d17f17f95e Mon Sep 17 00:00:00 2001 From: bpark1327 Date: Mon, 24 Jul 2023 10:30:47 -0600 Subject: [PATCH 1/4] use ASRE instead of SRE for mech vent --- rulesets/data/zerh_sf_2_0_lookup.tsv | 3 +- rulesets/resources/ES_ZERHruleset.rb | 2 + rulesets/tests/test_es_zerh_ventilation.rb | 51 +++++++++++++++++++--- 3 files changed, 48 insertions(+), 8 deletions(-) diff --git a/rulesets/data/zerh_sf_2_0_lookup.tsv b/rulesets/data/zerh_sf_2_0_lookup.tsv index b7c77fd2a..c0230a4d6 100644 --- a/rulesets/data/zerh_sf_2_0_lookup.tsv +++ b/rulesets/data/zerh_sf_2_0_lookup.tsv @@ -97,5 +97,6 @@ infil_air_leakage_ach50 single-family attached 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 infil_air_leakage_ach50 apartment unit 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 infil_air_leakage_cfm50_per_sqft mechanical_ventilation_fan_type supply only supply only supply only supply only supply only supply only supply only supply only supply only supply only supply only heat recovery ventilator heat recovery ventilator heat recovery ventilator heat recovery ventilator heat recovery ventilator heat recovery ventilator heat recovery ventilator heat recovery ventilator heat recovery ventilator -mechanical_ventilation_fan_sre 0.65 0.65 0.65 0.65 0.65 0.65 0.65 0.65 0.65 +mechanical_ventilation_fan_sre +mechanical_ventilation_fan_asre 0.65 0.65 0.65 0.65 0.65 0.65 0.65 0.65 0.65 mechanical_ventilation_fan_cfm_per_w 2.9 2.9 2.9 2.9 2.9 2.9 2.9 2.9 2.9 2.9 2.9 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 diff --git a/rulesets/resources/ES_ZERHruleset.rb b/rulesets/resources/ES_ZERHruleset.rb index 514321f55..e6c6d5d13 100644 --- a/rulesets/resources/ES_ZERHruleset.rb +++ b/rulesets/resources/ES_ZERHruleset.rb @@ -796,6 +796,7 @@ def self.set_systems_mechanical_ventilation_reference(new_hpxml) fan_type = lookup_reference_value('mechanical_ventilation_fan_type') fan_cfm_per_w = lookup_reference_value('mechanical_ventilation_fan_cfm_per_w') fan_sre = lookup_reference_value('mechanical_ventilation_fan_sre') + fan_asre = lookup_reference_value('mechanical_ventilation_fan_asre') fan_power_w = fan_cfm / fan_cfm_per_w new_hpxml.ventilation_fans.add(id: 'TargetVentilationFan', @@ -805,6 +806,7 @@ def self.set_systems_mechanical_ventilation_reference(new_hpxml) hours_in_operation: 24, fan_power: fan_power_w.round(3), sensible_recovery_efficiency: fan_sre, + sensible_recovery_efficiency_adjusted: fan_asre, used_for_whole_building_ventilation: true) end diff --git a/rulesets/tests/test_es_zerh_ventilation.rb b/rulesets/tests/test_es_zerh_ventilation.rb index e35a2c1ee..2b0ae483b 100644 --- a/rulesets/tests/test_es_zerh_ventilation.rb +++ b/rulesets/tests/test_es_zerh_ventilation.rb @@ -76,11 +76,20 @@ def sre(program_version, hpxml) return 0.6 end elsif [ZERHConstants.SFVer2].include? program_version + return + end + end + + def asre(program_version, hpxml) + iecc_zone = hpxml.climate_and_risk_zones.climate_zone_ieccs[0].zone + if [ZERHConstants.SFVer2].include? program_version if ['1A', '1B', '1C', '2A', '2B', '2C', '3A', '3B', '3C', '4A', '4B'].include? iecc_zone return elsif ['4C', '5A', '5B', '5C', '6A', '6B', '6C', '7', '8'].include? iecc_zone return 0.65 end + else + return end end @@ -88,7 +97,11 @@ def test_mech_vent [*ESConstants.AllVersions, *ZERHConstants.AllVersions].each do |program_version| _convert_to_es_zerh('base.xml', program_version) hpxml = _test_ruleset(program_version) - _check_mech_vent(hpxml, [{ fantype: fan_type(program_version, hpxml), flowrate: 57.0, hours: 24, power: (57.0 / cfm_per_watt(program_version, hpxml)), sre: sre(program_version, hpxml) }]) + if program_version == ZERHConstants.SFVer2 + _check_mech_vent(hpxml, [{ fantype: fan_type(program_version, hpxml), flowrate: 57.0, hours: 24, power: (57.0 / cfm_per_watt(program_version, hpxml)), asre: asre(program_version, hpxml) }]) + else + _check_mech_vent(hpxml, [{ fantype: fan_type(program_version, hpxml), flowrate: 57.0, hours: 24, power: (57.0 / cfm_per_watt(program_version, hpxml)), sre: sre(program_version, hpxml) }]) + end end end @@ -96,7 +109,11 @@ def test_mech_vent_attached_or_multifamily ESConstants.AllVersions.each do |program_version| _convert_to_es_zerh('base-bldgtype-multifamily.xml', program_version) hpxml = _test_ruleset(program_version) - _check_mech_vent(hpxml, [{ fantype: fan_type(program_version, hpxml), flowrate: 39.0, hours: 24, power: (39.0 / cfm_per_watt(program_version, hpxml)), sre: sre(program_version, hpxml) }]) + if program_version == ZERHConstants.SFVer2 + _check_mech_vent(hpxml, [{ fantype: fan_type(program_version, hpxml), flowrate: 39.0, hours: 24, power: (39.0 / cfm_per_watt(program_version, hpxml)), asre: asre(program_version, hpxml) }]) + else + _check_mech_vent(hpxml, [{ fantype: fan_type(program_version, hpxml), flowrate: 39.0, hours: 24, power: (39.0 / cfm_per_watt(program_version, hpxml)), sre: sre(program_version, hpxml) }]) + end end end @@ -104,7 +121,11 @@ def test_mech_vent_erv [*ESConstants.AllVersions, *ZERHConstants.AllVersions].each do |program_version| _convert_to_es_zerh('base-mechvent-erv.xml', program_version) hpxml = _test_ruleset(program_version) - _check_mech_vent(hpxml, [{ fantype: fan_type(program_version, hpxml), flowrate: 57.0, hours: 24, power: (57.0 / cfm_per_watt(program_version, hpxml)), sre: sre(program_version, hpxml) }]) + if program_version == ZERHConstants.SFVer2 + _check_mech_vent(hpxml, [{ fantype: fan_type(program_version, hpxml), flowrate: 57.0, hours: 24, power: (57.0 / cfm_per_watt(program_version, hpxml)), asre: asre(program_version, hpxml) }]) + else + _check_mech_vent(hpxml, [{ fantype: fan_type(program_version, hpxml), flowrate: 57.0, hours: 24, power: (57.0 / cfm_per_watt(program_version, hpxml)), sre: sre(program_version, hpxml) }]) + end end end @@ -112,7 +133,11 @@ def test_mech_vent_hrv [*ESConstants.AllVersions, *ZERHConstants.AllVersions].each do |program_version| _convert_to_es_zerh('base-mechvent-hrv.xml', program_version) hpxml = _test_ruleset(program_version) - _check_mech_vent(hpxml, [{ fantype: fan_type(program_version, hpxml), flowrate: 57.0, hours: 24, power: (57.0 / cfm_per_watt(program_version, hpxml)), sre: sre(program_version, hpxml) }]) + if program_version == ZERHConstants.SFVer2 + _check_mech_vent(hpxml, [{ fantype: fan_type(program_version, hpxml), flowrate: 57.0, hours: 24, power: (57.0 / cfm_per_watt(program_version, hpxml)), asre: asre(program_version, hpxml) }]) + else + _check_mech_vent(hpxml, [{ fantype: fan_type(program_version, hpxml), flowrate: 57.0, hours: 24, power: (57.0 / cfm_per_watt(program_version, hpxml)), sre: sre(program_version, hpxml) }]) + end end end @@ -120,7 +145,11 @@ def test_mech_vent_nbeds_5 [*ESConstants.AllVersions, *ZERHConstants.AllVersions].each do |program_version| _convert_to_es_zerh('base-enclosure-beds-5.xml', program_version) hpxml = _test_ruleset(program_version) - _check_mech_vent(hpxml, [{ fantype: fan_type(program_version, hpxml), flowrate: 72.0, hours: 24, power: (72.0 / cfm_per_watt(program_version, hpxml)), sre: sre(program_version, hpxml) }]) + if program_version == ZERHConstants.SFVer2 + _check_mech_vent(hpxml, [{ fantype: fan_type(program_version, hpxml), flowrate: 72.0, hours: 24, power: (72.0 / cfm_per_watt(program_version, hpxml)), asre: asre(program_version, hpxml) }]) + else + _check_mech_vent(hpxml, [{ fantype: fan_type(program_version, hpxml), flowrate: 72.0, hours: 24, power: (72.0 / cfm_per_watt(program_version, hpxml)), sre: sre(program_version, hpxml) }]) + end end end @@ -128,7 +157,11 @@ def test_mech_vent_location_miami_fl [*ESConstants.AllVersions, *ZERHConstants.AllVersions].each do |program_version| _convert_to_es_zerh('base-location-miami-fl.xml', program_version) hpxml = _test_ruleset(program_version) - _check_mech_vent(hpxml, [{ fantype: fan_type(program_version, hpxml), flowrate: 43.5, hours: 24, power: (43.5 / cfm_per_watt(program_version, hpxml)), sre: sre(program_version, hpxml) }]) + if program_version == ZERHConstants.SFVer2 + _check_mech_vent(hpxml, [{ fantype: fan_type(program_version, hpxml), flowrate: 43.5, hours: 24, power: (43.5 / cfm_per_watt(program_version, hpxml)), asre: asre(program_version, hpxml) }]) + else + _check_mech_vent(hpxml, [{ fantype: fan_type(program_version, hpxml), flowrate: 43.5, hours: 24, power: (43.5 / cfm_per_watt(program_version, hpxml)), sre: sre(program_version, hpxml) }]) + end end end @@ -145,7 +178,11 @@ def test_mech_vent_attached_or_multifamily_location_miami_fl hpxml.climate_and_risk_zones.weather_station_wmo = 722020 XMLHelper.write_file(hpxml.to_oga, @tmp_hpxml_path) hpxml = _test_ruleset(program_version) - _check_mech_vent(hpxml, [{ fantype: fan_type(program_version, hpxml), flowrate: 39.0, hours: 24, power: (39.0 / cfm_per_watt(program_version, hpxml)), sre: sre(program_version, hpxml) }]) + if program_version == ZERHConstants.SFVer2 + _check_mech_vent(hpxml, [{ fantype: fan_type(program_version, hpxml), flowrate: 39.0, hours: 24, power: (39.0 / cfm_per_watt(program_version, hpxml)), asre: asre(program_version, hpxml) }]) + else + _check_mech_vent(hpxml, [{ fantype: fan_type(program_version, hpxml), flowrate: 39.0, hours: 24, power: (39.0 / cfm_per_watt(program_version, hpxml)), sre: sre(program_version, hpxml) }]) + end end end From 10ab8c8dd612073c1e04071d7eb55f619e804a9c Mon Sep 17 00:00:00 2001 From: bpark1327 Date: Mon, 24 Jul 2023 10:38:05 -0600 Subject: [PATCH 2/4] update changelog [ci skip] --- Changelog.md | 1 + 1 file changed, 1 insertion(+) diff --git a/Changelog.md b/Changelog.md index 05c612bf6..5da34f161 100644 --- a/Changelog.md +++ b/Changelog.md @@ -39,6 +39,7 @@ __Bugfixes__ - Adds error-checking to ensure that SFA/MF dwelling units have at least one attached wall/ceiling/floor surface. - Various Manual J HVAC autosizing calculation bugfixes and improvements. - Ensure that ductless HVAC systems do not have a non-zero airflow defect ratio specified. +- ZERH Single Family v2 uses ASRE instead of SRE for mechanical ventilation fans. ## OpenStudio-ERI v1.5.2 From 4ff7df391228321437923bf8d1c1560e474c33d6 Mon Sep 17 00:00:00 2001 From: GitHub Action Date: Mon, 24 Jul 2023 20:22:27 +0000 Subject: [PATCH 3/4] Latest results. --- workflow/tests/base_results/real_homes.csv | 72 ++--- workflow/tests/base_results/sample_files.csv | 272 +++++++++---------- 2 files changed, 172 insertions(+), 172 deletions(-) diff --git a/workflow/tests/base_results/real_homes.csv b/workflow/tests/base_results/real_homes.csv index 65484297e..c2b33e2b3 100644 --- a/workflow/tests/base_results/real_homes.csv +++ b/workflow/tests/base_results/real_homes.csv @@ -2,62 +2,62 @@ XML,ERI,REUL Heating (MBtu),REUL Cooling (MBtu),REUL Hot Water (MBtu),EC_r Heati house001.xml,57.87,11.65,2.05,6.49,18.61,2.23,12.49,9.34,1.25,9.82,10.06,0.79,0.0,0.23231,66.54,5799.15,8126.44,1.0724,52.33,1.0,52.33,57.87,57.87,0.0,56.41,1.0,56.41,57.87,57.87,0.0,59.7,10.57,2.14,6.49,16.88,2.26,12.48,9.34,1.25,9.82,10.06,0.79,0.0,0.23231 house002.xml,74.64,51.96,21.19,9.54,41.96,12.31,10.56,31.86,6.61,9.45,24.05,0.0,0.0,0.18421,75.55,13179.86,17740.02,0.9834,49.22,1.0,49.22,74.64,74.64,0.0,46.87,1.0,46.87,74.64,74.64,0.0,69.3,60.33,21.2,9.54,48.5,12.8,10.56,31.86,6.61,9.45,24.05,0.0,0.0,0.18421 house003.xml,62.03,27.96,21.91,8.83,31.29,12.74,16.03,18.25,7.42,7.24,22.14,1.14,0.0,0.24213,72.73,9338.52,12936.06,0.9926,47.87,1.0,47.87,62.03,62.03,0.0,46.32,1.0,46.32,62.03,62.03,0.0,59.47,31.29,21.65,8.83,34.54,13.09,16.04,18.25,7.42,7.24,22.14,1.14,0.0,0.24213 -house004.xml,60.75,49.94,3.04,13.08,46.47,1.59,14.34,30.13,0.37,5.38,16.12,3.1,0.0,0.31917,66.21,4917.09,7112.5,1.0442,54.75,1.0,54.75,60.75,60.75,0.0,46.4,1.0,46.4,60.75,60.75,0.0,55.32,59.86,2.51,13.08,55.12,1.36,14.34,30.13,0.37,5.38,16.12,3.1,0.0,0.31917 +house004.xml,60.75,49.94,3.04,13.08,46.47,1.59,14.34,30.13,0.37,5.38,16.12,3.1,0.0,0.31917,66.21,4917.09,7112.5,1.0442,54.75,1.0,54.75,60.75,60.75,0.0,47.19,1.0,47.19,60.75,60.75,0.0,55.32,59.86,2.51,13.08,55.12,1.36,14.34,30.13,0.37,5.38,16.12,3.1,0.0,0.31917 house005.xml,56.73,6.21,4.08,5.79,5.21,2.43,12.13,1.3,1.59,4.06,8.94,1.79,0.0,0.20459,79.27,2691.16,3148.06,1.0785,48.15,1.0,48.15,56.73,56.73,0.0,56.16,1.0,56.16,56.73,56.73,0.0,57.82,5.59,4.16,5.79,4.78,2.44,12.12,1.3,1.59,4.06,8.94,1.79,0.0,0.20459 house006.xml,71.2,31.94,20.58,10.54,24.12,12.09,11.82,16.08,7.55,10.52,21.3,1.46,0.0,0.23786,72.43,10110.93,13703.09,1.0187,45.13,1.0,45.13,71.2,71.2,0.0,43.3,1.0,43.3,71.2,71.2,0.0,69.33,34.12,20.42,10.54,25.76,12.3,11.82,16.08,7.55,10.52,21.3,1.46,0.0,0.23786 house007.xml,76.48,19.07,4.72,8.85,16.1,2.76,9.88,13.28,0.56,8.48,14.96,1.35,0.0,0.23293,78.61,9442.47,11370.22,1.0564,54.38,1.0,54.38,76.48,76.48,0.0,54.38,1.0,54.38,76.48,76.48,0.0,78.27,17.67,4.83,8.85,15.04,2.79,9.87,13.28,0.56,8.48,14.96,1.35,0.0,0.23293 -house008.xml,62.79,97.26,10.81,13.22,154.98,7.13,22.24,83.08,3.69,14.8,37.43,0.33,0.0,0.20102,73.57,24480.42,34221.86,0.9723,50.56,1.0,50.56,62.79,62.79,0.0,45.09,1.0,45.09,62.79,62.79,0.0,57.49,112.27,10.27,13.22,178.9,7.02,22.26,83.08,3.69,14.8,37.43,0.33,0.0,0.20102 +house008.xml,62.79,97.26,10.81,13.22,154.98,7.13,22.24,83.08,3.69,14.8,37.43,0.33,0.0,0.20102,73.57,24480.42,34221.86,0.9723,50.56,1.0,50.56,62.79,62.79,0.0,45.75,1.0,45.75,62.79,62.79,0.0,57.49,112.27,10.27,13.22,178.9,7.02,22.26,83.08,3.69,14.8,37.43,0.33,0.0,0.20102 house009.xml,62.52,19.55,41.48,8.99,31.33,25.2,16.45,16.37,13.95,12.39,23.29,0.59,0.0,0.28352,84.58,9978.89,11519.46,1.0242,48.63,1.0,48.63,62.52,62.52,0.0,45.66,1.0,45.66,62.52,62.52,0.0,60.06,22.11,41.86,8.99,35.42,26.21,16.45,16.37,13.95,12.39,23.29,0.59,0.0,0.28352 house010.xml,64.76,52.45,134.22,7.12,83.94,75.53999999999999,13.52,41.76,43.43,6.14,43.24,2.39,0.0,0.28027,96.22,17326.02,19865.61,0.9064,54.11,1.0,54.11,64.76,64.76,0.0,48.85,1.0,48.85,64.76,64.76,0.0,62.29,59.07000000000001,137.45,7.12,94.51,77.47,13.52,41.76,43.43,6.14,43.24,2.39,0.0,0.28027 house011.xml,56.47,12.1,6.31,7.89,19.36,4.6,8.9,6.68,1.77,8.2,12.64,0.0,0.0,0.27467,72.85,3447.99,4421.71,1.0705,51.77,1.0,51.77,56.47,56.47,0.0,57.56,1.0,57.56,56.47,56.47,1.0,59.38,9.89,6.52,7.89,15.82,4.63,8.9,6.68,1.77,8.2,12.64,0.0,0.0,0.27467 -house012.xml,54.57,35.07,2.9,11.63,29.9,1.65,12.68,11.84,0.78,10.73,14.75,0.0,0.0,0.31582,55.37,5803.67,10018.49,1.0462,50.13,1.0,50.13,54.57,54.57,0.0,41.78,1.0,41.78,54.57,54.57,0.0,50.37,41.18,2.63,11.63,34.93,1.57,12.68,11.84,0.78,10.73,14.75,0.0,0.0,0.31582 -house013.xml,58.96,12.1,1.79,10.35,8.93,0.87,11.97,6.66,0.19,3.37,13.97,0.64,0.0,0.16588,57.51,1703.03,2810.66,1.0535,52.36,1.0,52.36,58.96,58.96,0.0,47.14,1.0,47.14,58.96,58.96,0.0,57.96,13.1,1.68,10.35,9.58,0.82,11.97,6.66,0.19,3.37,13.97,0.64,0.0,0.16588 +house012.xml,54.57,35.07,2.9,11.63,29.9,1.65,12.68,11.84,0.78,10.73,14.75,0.0,0.0,0.31582,55.37,5803.67,10018.49,1.0462,50.13,1.0,50.13,54.57,54.57,0.0,42.51,1.0,42.51,54.57,54.57,0.0,50.37,41.18,2.63,11.63,34.93,1.57,12.68,11.84,0.78,10.73,14.75,0.0,0.0,0.31582 +house013.xml,58.96,12.1,1.79,10.35,8.93,0.87,11.97,6.66,0.19,3.37,13.97,0.64,0.0,0.16588,57.51,1703.03,2810.66,1.0535,52.36,1.0,52.36,58.96,58.96,0.0,47.5,1.0,47.5,58.96,58.96,0.0,57.96,13.1,1.68,10.35,9.58,0.82,11.97,6.66,0.19,3.37,13.97,0.64,0.0,0.16588 house014.xml,48.28,88.66,28.17,15.51,65.62,15.61,17.2,23.62,6.220000000000001,3.68,36.46,4.19,0.0,0.25589,49.6,8445.42,17256.46,0.9867,46.62,1.0,46.62,48.28,48.28,0.0,44.26,1.0,44.26,48.28,48.28,0.0,44.45,104.12,27.589999999999996,15.51,76.74000000000001,16.04,17.2,23.62,6.220000000000001,3.68,36.46,4.19,0.0,0.25589 -house015.xml,14.95,0.2,22.24,3.31,0.27,12.36,5.93,0.17,5.23,1.44,9.6,0.21,0.0,0.27929,20.86,819.75,3463.64,1.1348,49.3,1.0,49.3,46.96,46.96,1.0,49.39,1.0,49.39,46.96,46.96,1.0,44.53,0.22,22.29,3.31,0.28,12.4,5.93,0.17,5.23,1.44,9.6,0.21,0.0,0.27929 -house016.xml,41.04,0.61,72.6,5.61,0.54,40.34,11.59,0.22,12.74,10.53,18.36,0.0,0.0,0.27953,63.27,5287.58,8016.35,1.0425,50.4,1.0,50.4,41.04,41.04,1.0,50.54,1.0,50.54,41.04,41.04,1.0,40.9,0.67,72.83,5.61,0.58,40.52,11.59,0.22,12.74,10.53,18.36,0.0,0.0,0.27953 -house017.xml,68.76,20.52,5.57,10.95,32.68,3.8,18.88,36.8,1.41,9.12,15.89,0.48,0.0,0.19856,175.88,8163.3,4434.54,1.0466,51.85,1.0,51.85,68.76,68.76,0.0,46.32,1.0,46.32,68.76,68.76,0.0,65.09,24.0,5.33,10.95,38.2,3.69,18.9,36.8,1.41,9.12,15.89,0.48,0.0,0.19856 +house015.xml,14.95,0.2,22.24,3.31,0.27,12.36,5.93,0.17,5.23,1.44,9.6,0.21,0.0,0.27929,20.86,819.75,3463.64,1.1348,49.3,1.0,49.3,46.96,46.96,1.0,49.51,1.0,49.51,46.96,46.96,1.0,44.53,0.22,22.29,3.31,0.28,12.4,5.93,0.17,5.23,1.44,9.6,0.21,0.0,0.27929 +house016.xml,41.04,0.61,72.6,5.61,0.54,40.34,11.59,0.22,12.74,10.53,18.36,0.0,0.0,0.27953,63.27,5287.58,8016.35,1.0425,50.4,1.0,50.4,41.04,41.04,1.0,50.69,1.0,50.69,41.04,41.04,1.0,40.9,0.67,72.83,5.61,0.58,40.52,11.59,0.22,12.74,10.53,18.36,0.0,0.0,0.27953 +house017.xml,68.76,20.52,5.57,10.95,32.68,3.8,18.88,36.8,1.41,9.12,15.89,0.48,0.0,0.19856,175.88,8163.3,4434.54,1.0466,51.85,1.0,51.85,68.76,68.76,0.0,46.91,1.0,46.91,68.76,68.76,0.0,65.09,24.0,5.33,10.95,38.2,3.69,18.9,36.8,1.41,9.12,15.89,0.48,0.0,0.19856 house018.xml,30.56,150.92000000000002,31.86,17.34,240.51,21.18,27.24,121.53,10.94,18.26,48.3,0.9,0.0,0.22681,95.61,23620.19,25776.46,0.9584,50.84,1.0,50.84,53.73,53.73,0.0,45.37,1.0,45.37,53.73,53.73,0.0,45.24,172.98,31.28,17.34,275.43,21.59,27.26,121.53,10.94,18.26,48.3,0.9,0.0,0.22681 -house019.xml,63.0,97.76,10.73,13.22,155.98,7.23,22.24,97.79,2.21,15.29,29.84,4.56,0.0,0.19251,75.45,25420.52,34502.81,0.9764,51.11,1.0,51.11,63.0,63.0,0.0,45.1,1.0,45.1,63.0,63.0,0.0,57.57,113.62,10.16,13.22,181.06,7.15,22.26,97.79,2.21,15.29,29.84,4.56,0.0,0.19251 -house020.xml,39.44,90.44,12.65,13.08,104.99,7.38,14.11,92.97999999999999,5.58,13.08,33.48,3.62,0.0,0.25965,114.06,13128.83,11761.02,0.9787,55.27,1.0,55.27,82.64,82.64,0.0,49.21,1.0,49.21,82.64,82.64,0.0,71.6,103.17,12.23,13.08,119.26,7.21,14.12,92.97999999999999,5.58,13.08,33.48,3.62,0.0,0.25965 -house021.xml,60.05,54.07,8.95,15.33,86.16,6.03,24.62,49.41,4.62,17.76,19.62,2.69,0.0,0.27064,66.06,16148.3,23296.66,1.0493,52.91,1.0,52.91,60.05,60.05,0.0,47.04,1.0,47.04,60.05,60.05,0.0,55.95,61.87,8.52,15.33,98.59,5.98,24.64,49.41,4.62,17.76,19.62,2.69,0.0,0.27064 -house022.xml,39.02,0.47,53.63,4.5,0.45,30.29,5.7,0.26,7.22,2.25,15.85,2.09,0.0,0.2436,48.45,3240.76,6436.33,1.0393,50.41,1.0,50.41,39.02,39.02,1.0,50.32,1.0,50.32,39.02,39.02,1.0,38.87,0.53,53.85,4.5,0.5,30.46,5.7,0.26,7.22,2.25,15.85,2.09,0.0,0.2436 +house019.xml,63.0,97.76,10.73,13.22,155.98,7.23,22.24,97.79,2.21,15.29,29.84,4.56,0.0,0.19251,75.45,25420.52,34502.81,0.9764,51.11,1.0,51.11,63.0,63.0,0.0,45.84,1.0,45.84,63.0,63.0,0.0,57.57,113.62,10.16,13.22,181.06,7.15,22.26,97.79,2.21,15.29,29.84,4.56,0.0,0.19251 +house020.xml,39.44,90.44,12.65,13.08,104.99,7.38,14.11,92.97999999999999,5.58,13.08,33.48,3.62,0.0,0.25965,114.06,13128.83,11761.02,0.9787,55.27,1.0,55.27,82.64,82.64,0.0,49.6,1.0,49.6,82.64,82.64,0.0,71.6,103.17,12.23,13.08,119.26,7.21,14.12,92.97999999999999,5.58,13.08,33.48,3.62,0.0,0.25965 +house021.xml,60.05,54.07,8.95,15.33,86.16,6.03,24.62,49.41,4.62,17.76,19.62,2.69,0.0,0.27064,66.06,16148.3,23296.66,1.0493,52.91,1.0,52.91,60.05,60.05,0.0,47.77,1.0,47.77,60.05,60.05,0.0,55.95,61.87,8.52,15.33,98.59,5.98,24.64,49.41,4.62,17.76,19.62,2.69,0.0,0.27064 +house022.xml,39.02,0.47,53.63,4.5,0.45,30.29,5.7,0.26,7.22,2.25,15.85,2.09,0.0,0.2436,48.45,3240.76,6436.33,1.0393,50.41,1.0,50.41,39.02,39.02,1.0,50.49,1.0,50.49,39.02,39.02,1.0,38.87,0.53,53.85,4.5,0.5,30.46,5.7,0.26,7.22,2.25,15.85,2.09,0.0,0.2436 house023.xml,70.95,16.49,39.07,6.02,12.15,22.66,7.26,7.09,14.29,5.84,18.89,3.94,0.0,0.25822,72.88,7476.97,10200.84,1.0057,45.35,1.0,45.35,70.95,70.95,0.0,43.64,1.0,43.64,70.95,70.95,0.0,69.56,17.59,39.23,6.02,12.9,23.11,7.26,7.09,14.29,5.84,18.89,3.94,0.0,0.25822 house024.xml,68.18,21.81,44.08,8.99,34.94,26.89,16.09,22.97,14.74,12.54,23.96,3.89,0.0,0.2667,93.48,11621.74,12317.54,1.0093,52.93,1.0,52.93,68.18,68.18,0.0,49.64,1.0,49.64,68.18,68.18,0.0,65.21,24.94,44.57,8.99,39.96,28.11,16.09,22.97,14.74,12.54,23.96,3.89,0.0,0.2667 -house025.xml,7.3,107.7,19.0,12.54,79.82,10.24,13.86,35.5,5.640000000000001,2.61,36.94,2.69,0.0,0.15611,20.34,2632.2,13500.11,0.9585,49.45,1.0,49.45,54.03,54.03,0.0,43.47,1.0,43.47,54.03,54.03,0.0,48.0,121.7,19.02,12.54,89.38,10.27,13.86,35.5,5.640000000000001,2.61,36.94,2.69,0.0,0.15611 +house025.xml,7.3,107.7,19.0,12.54,79.82,10.24,13.86,35.5,5.640000000000001,2.61,36.94,2.69,0.0,0.15611,20.34,2632.2,13500.11,0.9585,49.45,1.0,49.45,54.03,54.03,0.0,43.83,1.0,43.83,54.03,54.03,0.0,48.0,121.7,19.02,12.54,89.38,10.27,13.86,35.5,5.640000000000001,2.61,36.94,2.69,0.0,0.15611 house026.xml,65.38,11.7,29.34,7.52,18.74,18.05,14.12,10.03,10.41,14.26,19.05,0.46,0.0,0.21219,90.75,8075.91,8522.53,1.0442,46.95,1.0,46.95,65.38,65.38,0.0,44.44,1.0,44.44,65.38,65.38,0.0,63.54,13.03,29.53,7.52,20.88,18.58,14.12,10.03,10.41,14.26,19.05,0.46,0.0,0.21219 house027.xml,66.14,15.85,36.92,7.53,25.39,22.46,14.44,15.56,12.63,11.7,19.74,3.37,0.0,0.29866,88.87,9383.96,10179.92,1.0373,51.99,1.0,51.99,66.14,66.14,0.0,48.72,1.0,48.72,66.14,66.14,0.0,64.85,16.93,37.08,7.53,27.13,22.91,14.45,15.56,12.63,11.7,19.74,3.37,0.0,0.29866 house028.xml,65.06,22.58,47.72,10.42,16.48,28.37,11.67,9.0,16.77,8.78,25.84,0.73,0.0,0.28417,67.14,9169.47,13409.84,1.0185,44.2,1.0,44.2,65.06,65.06,0.0,42.49,1.0,42.49,65.06,65.06,0.0,62.34,25.89,48.23,10.42,18.7,29.55,11.67,9.0,16.77,8.78,25.84,0.73,0.0,0.28417 house029.xml,61.29,22.32,46.739999999999995,8.98,35.769999999999996,28.880000000000003,16.1,21.66,14.690000000000001,9.36,26.67,0.62,0.0,0.2536,84.18,10929.7,12984.92,0.9999,49.18,1.0,49.18,61.29,61.29,0.0,46.28,1.0,46.28,61.29,61.29,0.0,58.51,25.73,47.269999999999996,8.98,41.230000000000004,30.21,16.1,21.66,14.690000000000001,9.36,26.67,0.62,0.0,0.2536 house030.xml,59.66,28.18,57.099999999999994,10.42,45.15,35.07,17.96,27.37,19.6,9.28,27.93,0.75,0.0,0.29209,81.93,12764.6,15539.78,1.0026,50.02,1.0,50.02,59.66,59.66,0.0,46.93,1.0,46.93,59.66,59.66,0.0,56.84,32.31,57.760000000000005,10.42,51.78,36.7,17.96,27.37,19.6,9.28,27.93,0.75,0.0,0.29209 -house031.xml,52.83,122.05999999999999,19.49,14.54,90.33000000000001,10.48,17.33,40.230000000000004,6.95,3.34,36.88,2.99,0.0,-0.03578,52.66,7731.73,14580.72,1.007,47.94,1.0,47.94,52.83,52.83,0.0,42.35,1.0,42.35,52.83,52.83,0.0,49.44,137.06,19.42,14.54,100.67,10.48,17.33,40.230000000000004,6.95,3.34,36.88,2.99,0.0,-0.03578 +house031.xml,52.83,122.05999999999999,19.49,14.54,90.33000000000001,10.48,17.33,40.230000000000004,6.95,3.34,36.88,2.99,0.0,-0.03578,52.66,7731.73,14580.72,1.007,47.94,1.0,47.94,52.83,52.83,0.0,42.68,1.0,42.68,52.83,52.83,0.0,49.44,137.06,19.42,14.54,100.67,10.48,17.33,40.230000000000004,6.95,3.34,36.88,2.99,0.0,-0.03578 house032.xml,69.55,26.0,55.230000000000004,8.99,41.650000000000006,33.5,16.34,26.900000000000002,20.36,13.07,26.02,4.6,0.0,0.26341,102.04,14904.88,14345.89,1.0182,54.57,1.0,54.57,69.55,69.55,0.0,51.06,1.0,51.06,69.55,69.55,0.0,67.87,27.91,55.52,8.99,44.69,34.31,16.34,26.900000000000002,20.36,13.07,26.02,4.6,0.0,0.26341 house033.xml,63.84,69.3,27.97,11.39,110.64,17.83,19.4,83.34,7.15,10.68,31.47,0.0,0.0,0.22319,90.13,20766.29,23764.3,0.9695,51.77,1.0,51.77,63.84,63.84,0.0,48.43,1.0,48.43,63.84,63.84,0.0,59.07,80.85,27.89,11.39,129.05,18.47,19.42,83.34,7.15,10.68,31.47,0.0,0.0,0.22319 -house034.xml,62.14,18.74,5.0,9.98,30.0,3.4,18.5,15.5,2.22,10.85,20.18,2.23,0.0,0.18869,151.85,5720.74,3661.79,1.0288,55.28,1.0,55.28,62.14,62.14,0.0,49.6,1.0,49.6,62.14,62.14,0.0,60.78,20.22,4.82,9.98,32.36,3.31,18.5,15.5,2.22,10.85,20.18,2.23,0.0,0.18869 -house035.xml,69.63,51.42,6.79,11.07,81.99,4.96,12.39,66.52,2.26,10.02,20.06,0.47,0.0,0.19341,79.63,17977.76,22662.35,0.9962,55.23,1.0,55.23,69.63,69.63,0.0,47.28,1.0,47.28,69.63,69.63,0.0,65.16,58.65,6.45,11.07,93.45,4.91,12.39,66.52,2.26,10.02,20.06,0.47,0.0,0.19341 -house036.xml,67.63,60.96,9.07,8.66,97.26,6.19,15.94,66.43,3.32,9.12,27.96,2.31,0.0,0.188,78.8,18639.46,24135.55,0.9801,54.78,1.0,54.78,67.67,67.67,0.0,48.09,1.0,48.09,67.67,67.67,0.0,63.21,69.11,8.75,8.66,110.15,6.1,15.96,66.43,3.32,9.12,27.96,2.31,0.0,0.188 -house037.xml,66.77,64.15,7.08,13.22,102.38,5.12,14.55,69.25,3.06,10.99,21.25,0.36,0.0,0.19404,77.93,19076.79,24218.18,1.0108,52.25,1.0,52.25,66.77,66.77,0.0,46.04,1.0,46.04,66.77,66.77,0.0,61.58,73.84,6.73,13.22,117.66,5.06,14.55,69.25,3.06,10.99,21.25,0.36,0.0,0.19404 +house034.xml,62.14,18.74,5.0,9.98,30.0,3.4,18.5,15.5,2.22,10.85,20.18,2.23,0.0,0.18869,151.85,5720.74,3661.79,1.0288,55.28,1.0,55.28,62.14,62.14,0.0,50.2,1.0,50.2,62.14,62.14,0.0,60.78,20.22,4.82,9.98,32.36,3.31,18.5,15.5,2.22,10.85,20.18,2.23,0.0,0.18869 +house035.xml,69.63,51.42,6.79,11.07,81.99,4.96,12.39,66.52,2.26,10.02,20.06,0.47,0.0,0.19341,79.63,17977.76,22662.35,0.9962,55.23,1.0,55.23,69.63,69.63,0.0,48.3,1.0,48.3,69.63,69.63,0.0,65.16,58.65,6.45,11.07,93.45,4.91,12.39,66.52,2.26,10.02,20.06,0.47,0.0,0.19341 +house036.xml,67.63,60.96,9.07,8.66,97.26,6.19,15.94,66.43,3.32,9.12,27.96,2.31,0.0,0.188,78.8,18639.46,24135.55,0.9801,54.78,1.0,54.78,67.67,67.67,0.0,48.93,1.0,48.93,67.67,67.67,0.0,63.21,69.11,8.75,8.66,110.15,6.1,15.96,66.43,3.32,9.12,27.96,2.31,0.0,0.188 +house037.xml,66.77,64.15,7.08,13.22,102.38,5.12,14.55,69.25,3.06,10.99,21.25,0.36,0.0,0.19404,77.93,19076.79,24218.18,1.0108,52.25,1.0,52.25,66.77,66.77,0.0,46.82,1.0,46.82,66.77,66.77,0.0,61.58,73.84,6.73,13.22,117.66,5.06,14.55,69.25,3.06,10.99,21.25,0.36,0.0,0.19404 house038.xml,64.19,39.1,39.34,9.93,35.11,22.53,17.64,23.78,11.870000000000001,12.25,27.65,0.82,0.0,0.26537,72.26,13753.13,19568.18,0.9727,46.46,1.0,46.46,64.19,64.19,0.0,44.56,1.0,44.56,64.19,64.19,0.0,62.05,42.92,39.19,9.93,38.11,23.049999999999997,17.64,23.78,11.870000000000001,12.25,27.65,0.82,0.0,0.26537 -house039.xml,50.73,72.63,19.98,16.51,115.71000000000001,13.25,29.76,126.54,6.63,24.92,36.28,0.0,0.0,0.09374,206.53,22913.63,11122.68,0.9975,53.03,1.0,53.03,89.0,89.0,0.0,47.86,1.0,47.86,89.0,89.0,0.0,73.91,86.93,19.87,16.51,138.46,13.18,29.76,126.54,6.63,24.92,36.28,0.0,0.0,0.09374 -house040.xml,63.91,124.08,12.96,11.07,197.79,8.4,19.44,111.59,9.34,15.31,32.38,2.19,0.0,0.18496,75.09,29272.97,40744.87,0.9568,52.26,1.0,52.26,63.91,63.91,0.0,48.42,1.0,48.42,63.91,63.91,0.0,59.27,139.99,12.41,11.07,223.07,8.03,19.46,111.59,9.34,15.31,32.38,2.19,0.0,0.18496 -house041.xml,78.2,25.13,8.2,12.54,40.02,5.28,20.93,27.73,4.2,20.38,23.5,0.0,0.0,0.13089,171.2,9339.83,5329.75,1.0236,52.59,1.0,52.59,78.2,78.2,0.0,45.06,1.0,45.06,78.2,78.2,0.0,75.48,27.86,8.07,12.54,44.37,5.18,20.94,27.73,4.2,20.38,23.5,0.0,0.0,0.13089 +house039.xml,50.73,72.63,19.98,16.51,115.71000000000001,13.25,29.76,126.54,6.63,24.92,36.28,0.0,0.0,0.09374,206.53,22913.63,11122.68,0.9975,53.03,1.0,53.03,89.0,89.0,0.0,48.41,1.0,48.41,89.0,89.0,0.0,73.91,86.93,19.87,16.51,138.46,13.18,29.76,126.54,6.63,24.92,36.28,0.0,0.0,0.09374 +house040.xml,63.91,124.08,12.96,11.07,197.79,8.4,19.44,111.59,9.34,15.31,32.38,2.19,0.0,0.18496,75.09,29272.97,40744.87,0.9568,52.26,1.0,52.26,63.91,63.91,0.0,49.02,1.0,49.02,63.91,63.91,0.0,59.27,139.99,12.41,11.07,223.07,8.03,19.46,111.59,9.34,15.31,32.38,2.19,0.0,0.18496 +house041.xml,78.2,25.13,8.2,12.54,40.02,5.28,20.93,27.73,4.2,20.38,23.5,0.0,0.0,0.13089,171.2,9339.83,5329.75,1.0236,52.59,1.0,52.59,78.2,78.2,0.0,45.87,1.0,45.87,78.2,78.2,0.0,75.48,27.86,8.07,12.54,44.37,5.18,20.94,27.73,4.2,20.38,23.5,0.0,0.0,0.13089 house042.xml,86.97,49.27,21.06,11.39,78.7,13.11,19.74,75.55,10.33,15.56,27.23,0.0,0.0,0.21926,112.32,20208.14,18035.16,0.9976,49.5,1.0,49.5,86.97,86.97,0.0,46.39,1.0,46.39,86.97,86.97,0.0,81.02,57.05,20.97,11.39,91.11,13.51,19.75,75.55,10.33,15.56,27.23,0.0,0.0,0.21926 -house043.xml,-7.21,16.42,5.31,10.49,12.86,2.85,11.81,0.83,1.7,2.59,14.94,0.79,0.0,0.30003,0.95,41.85,4254.61,1.0349,49.15,1.0,49.15,38.76,38.76,1.0,43.61,1.0,43.61,38.76,38.76,1.0,36.72,16.58,5.31,10.49,12.97,2.84,11.81,0.83,1.7,2.59,14.94,0.79,0.0,0.30003 -house044.xml,68.27,19.24,3.57,6.35,30.72,2.95,7.66,25.27,1.86,5.34,9.53,0.52,0.0,0.16673,76.06,7622.32,9504.2,1.0545,51.59,1.0,51.59,68.27,68.27,0.0,46.85,1.0,46.85,68.27,68.27,0.0,66.92,20.13,3.51,6.35,32.13,2.94,7.67,25.27,1.86,5.34,9.53,0.52,0.0,0.16673 +house043.xml,-7.21,16.42,5.31,10.49,12.86,2.85,11.81,0.83,1.7,2.59,14.94,0.79,0.0,0.30003,0.95,41.85,4254.61,1.0349,49.15,1.0,49.15,38.76,38.76,1.0,44.3,1.0,44.3,38.76,38.76,1.0,36.72,16.58,5.31,10.49,12.97,2.84,11.81,0.83,1.7,2.59,14.94,0.79,0.0,0.30003 +house044.xml,68.27,19.24,3.57,6.35,30.72,2.95,7.66,25.27,1.86,5.34,9.53,0.52,0.0,0.16673,76.06,7622.32,9504.2,1.0545,51.59,1.0,51.59,68.27,68.27,0.0,47.47,1.0,47.47,68.27,68.27,0.0,66.92,20.13,3.51,6.35,32.13,2.94,7.67,25.27,1.86,5.34,9.53,0.52,0.0,0.16673 house045.xml,90.22,74.38,43.01,12.22,55.7,25.05,21.32,47.52,19.87,33.34,39.95,4.48,0.0,0.21977,100.7,25596.86,26478.03,0.96,48.84,1.0,48.84,90.22,90.22,0.0,44.74,1.0,44.74,90.22,90.22,0.0,84.64,85.14,42.29,12.22,63.59,25.88,21.32,47.52,19.87,33.34,39.95,4.48,0.0,0.21977 -house046.xml,-7.98,74.41,12.81,12.94,61.89,7.24,13.97,8.99,1.13,10.55,17.63,3.05,0.0,0.27817,5.5,1544.22,28231.3,0.9951,48.02,1.0,48.02,32.76,32.76,1.0,41.96,1.0,41.96,32.76,32.76,1.0,28.61,86.37,12.23,12.94,71.7,7.26,13.97,8.99,1.13,10.55,17.63,3.05,0.0,0.27817 -house047.xml,62.42,32.1,8.94,10.49,51.12,5.59,11.81,43.1,2.3,2.71,21.15,0.36,0.0,0.20892,164.32,10127.5,6137.04,1.0043,57.78,1.0,57.78,62.42,62.42,0.0,51.33,1.0,51.33,62.42,62.42,0.0,57.92,38.68,8.82,10.49,61.6,5.55,11.81,43.1,2.3,2.71,21.15,0.36,0.0,0.20892 +house046.xml,-7.98,74.41,12.81,12.94,61.89,7.24,13.97,8.99,1.13,10.55,17.63,3.05,0.0,0.27817,5.5,1544.22,28231.3,0.9951,48.02,1.0,48.02,32.76,32.76,1.0,42.47,1.0,42.47,32.76,32.76,1.0,28.61,86.37,12.23,12.94,71.7,7.26,13.97,8.99,1.13,10.55,17.63,3.05,0.0,0.27817 +house047.xml,62.42,32.1,8.94,10.49,51.12,5.59,11.81,43.1,2.3,2.71,21.15,0.36,0.0,0.20892,164.32,10127.5,6137.04,1.0043,57.78,1.0,57.78,62.42,62.42,0.0,52.13,1.0,52.13,62.42,62.42,0.0,57.92,38.68,8.82,10.49,61.6,5.55,11.81,43.1,2.3,2.71,21.15,0.36,0.0,0.20892 house048.xml,65.64,1.85,64.34,5.61,2.97,37.57,10.96,0.72,24.81,7.6,19.73,0.66,0.0,0.32816,81.95,6654.7,7686.3,1.0565,51.58,1.0,51.58,65.64,65.64,0.0,46.6,1.0,46.6,65.64,65.64,0.0,65.36,1.96,64.57,5.61,3.14,37.75,10.96,0.72,24.81,7.6,19.73,0.66,0.0,0.32816 -house049.xml,50.74,13.33,3.59,7.98,9.84,1.85,16.63,3.04,0.49,8.66,13.12,2.15,0.0,0.2243,88.63,2554.15,2740.78,1.0515,48.34,1.0,48.34,50.74,50.74,0.0,44.22,1.0,44.22,50.74,50.74,0.0,49.81,14.31,3.46,7.98,10.5,1.79,16.63,3.04,0.49,8.66,13.12,2.15,0.0,0.2243 -house050.xml,88.28,20.3,5.66,11.92,32.36,3.66,21.4,14.54,3.79,15.61,22.99,13.97,0.0,0.16747,175.92,7382.28,4129.67,1.0162,55.46,1.0,55.46,88.28,88.28,0.0,50.89,1.0,50.89,88.28,88.28,0.0,83.97,23.98,5.22,11.92,38.22,3.46,21.41,14.54,3.79,15.61,22.99,13.97,0.0,0.16747 -house051.xml,48.41,13.32,3.08,9.98,9.96,1.63,18.52,2.54,0.28,8.31,16.7,1.14,0.0,0.17835,83.88,2614.5,3043.02,1.0243,48.67,1.0,48.67,48.41,48.41,1.0,44.7,1.0,44.7,48.41,48.41,0.0,48.63,13.05,3.11,9.98,9.78,1.64,18.52,2.54,0.28,8.31,16.7,1.14,0.0,0.17835 -house052.xml,54.93,13.06,1.56,10.35,9.54,0.77,11.96,2.98,0.09,8.08,13.11,1.26,0.0,0.19205,56.11,1699.28,2862.18,1.058,52.26,1.0,52.26,54.93,54.93,0.0,47.3,1.0,47.3,54.93,54.93,0.0,54.13,13.82,1.49,10.35,10.06,0.73,11.96,2.98,0.09,8.08,13.11,1.26,0.0,0.19205 -house053.xml,70.63,20.55,5.44,11.92,32.76,3.56,21.37,20.76,2.44,14.97,22.57,0.9,0.0,0.168,172.84,7210.1,4100.02,1.0175,55.23,1.0,55.23,70.63,70.63,0.0,50.51,1.0,50.51,70.63,70.63,0.0,67.04,24.37,5.01,11.92,38.85,3.36,21.37,20.76,2.44,14.97,22.57,0.9,0.0,0.168 +house049.xml,50.74,13.33,3.59,7.98,9.84,1.85,16.63,3.04,0.49,8.66,13.12,2.15,0.0,0.2243,88.63,2554.15,2740.78,1.0515,48.34,1.0,48.34,50.74,50.74,0.0,44.52,1.0,44.52,50.74,50.74,0.0,49.81,14.31,3.46,7.98,10.5,1.79,16.63,3.04,0.49,8.66,13.12,2.15,0.0,0.2243 +house050.xml,88.28,20.3,5.66,11.92,32.36,3.66,21.4,14.54,3.79,15.61,22.99,13.97,0.0,0.16747,175.92,7382.28,4129.67,1.0162,55.46,1.0,55.46,88.28,88.28,0.0,51.41,1.0,51.41,88.28,88.28,0.0,83.97,23.98,5.22,11.92,38.22,3.46,21.41,14.54,3.79,15.61,22.99,13.97,0.0,0.16747 +house051.xml,48.41,13.32,3.08,9.98,9.96,1.63,18.52,2.54,0.28,8.31,16.7,1.14,0.0,0.17835,83.88,2614.5,3043.02,1.0243,48.67,1.0,48.67,48.41,48.41,1.0,45.0,1.0,45.0,48.41,48.41,0.0,48.63,13.05,3.11,9.98,9.78,1.64,18.52,2.54,0.28,8.31,16.7,1.14,0.0,0.17835 +house052.xml,54.93,13.06,1.56,10.35,9.54,0.77,11.96,2.98,0.09,8.08,13.11,1.26,0.0,0.19205,56.11,1699.28,2862.18,1.058,52.26,1.0,52.26,54.93,54.93,0.0,47.65,1.0,47.65,54.93,54.93,0.0,54.13,13.82,1.49,10.35,10.06,0.73,11.96,2.98,0.09,8.08,13.11,1.26,0.0,0.19205 +house053.xml,70.63,20.55,5.44,11.92,32.76,3.56,21.37,20.76,2.44,14.97,22.57,0.9,0.0,0.168,172.84,7210.1,4100.02,1.0175,55.23,1.0,55.23,70.63,70.63,0.0,51.04,1.0,51.04,70.63,70.63,0.0,67.04,24.37,5.01,11.92,38.85,3.36,21.37,20.76,2.44,14.97,22.57,0.9,0.0,0.168 house054.xml,62.06,3.4699999999999998,116.76,7.76,5.5600000000000005,68.55,13.57,1.76,42.91,6.47,28.18,1.46,0.0,0.32914,70.84,9666.55,13349.28,1.0222,50.76,1.0,50.76,62.06,62.06,0.0,45.68,1.0,45.68,62.06,62.06,0.0,61.69,3.73,117.33,7.76,5.9799999999999995,68.98,13.57,1.76,42.91,6.47,28.18,1.46,0.0,0.32914 house055.xml,63.98,1.86,63.73,5.61,2.99,37.12,10.69,1.22,24.37,5.91,18.6,1.01,0.0,0.33293,75.71,6137.89,7656.29,1.0589,49.83,1.0,49.83,63.98,63.98,0.0,44.96,1.0,44.96,63.98,63.98,0.0,63.79,1.94,63.89,5.61,3.11,37.24,10.69,1.22,24.37,5.91,18.6,1.01,0.0,0.33293 -house056.xml,62.6,24.93,5.86,11.92,39.91,3.86,20.97,21.369999999999997,2.36,11.91,24.34,2.61,0.0,0.20097,157.31,7070.68,4446.52,1.0108,54.39,1.0,54.39,62.6,62.6,0.0,48.96,1.0,48.96,62.6,62.6,0.0,59.07,29.62,5.39,11.92,47.410000000000004,3.64,20.97,21.369999999999997,2.36,11.91,24.34,2.61,0.0,0.20097 -house057.xml,82.02,17.99,4.73,9.98,28.68,3.18,11.55,16.17,3.48,3.22,19.13,11.34,0.0,0.16126,139.22,5060.46,3583.47,1.0144,57.61,1.0,57.61,82.02,82.02,0.0,53.29,1.0,53.29,82.02,82.02,0.0,78.0,21.13,4.37,9.98,33.69,3.01,11.55,16.17,3.48,3.22,19.13,11.34,0.0,0.16126 +house056.xml,62.6,24.93,5.86,11.92,39.91,3.86,20.97,21.369999999999997,2.36,11.91,24.34,2.61,0.0,0.20097,157.31,7070.68,4446.52,1.0108,54.39,1.0,54.39,62.6,62.6,0.0,49.55,1.0,49.55,62.6,62.6,0.0,59.07,29.62,5.39,11.92,47.410000000000004,3.64,20.97,21.369999999999997,2.36,11.91,24.34,2.61,0.0,0.20097 +house057.xml,82.02,17.99,4.73,9.98,28.68,3.18,11.55,16.17,3.48,3.22,19.13,11.34,0.0,0.16126,139.22,5060.46,3583.47,1.0144,57.61,1.0,57.61,82.02,82.02,0.0,53.81,1.0,53.81,82.02,82.02,0.0,78.0,21.13,4.37,9.98,33.69,3.01,11.55,16.17,3.48,3.22,19.13,11.34,0.0,0.16126 house058.xml,64.83,3.34,80.11,6.7,5.35,47.18,12.54,1.35,29.23,10.91,21.41,0.9,0.0,0.32806,78.91,7741.08,9692.19,1.0122,51.44,1.0,51.44,64.83,64.83,0.0,46.43,1.0,46.43,64.83,64.83,0.0,63.82,3.88,81.19,6.7,6.21,47.99,12.54,1.35,29.23,10.91,21.41,0.9,0.0,0.32806 -house059.xml,51.45,7.26,3.49,7.98,5.74,1.77,15.01,1.73,0.46,6.95,14.27,0.12,0.0,0.19241,100.93,2351.41,2168.45,1.0743,49.93,1.0,49.93,51.45,51.45,0.0,46.64,1.0,46.64,51.45,51.45,0.0,50.73,7.95,3.34,7.98,6.2,1.7,15.02,1.73,0.46,6.95,14.27,0.12,0.0,0.19241 +house059.xml,51.45,7.26,3.49,7.98,5.74,1.77,15.01,1.73,0.46,6.95,14.27,0.12,0.0,0.19241,100.93,2351.41,2168.45,1.0743,49.93,1.0,49.93,51.45,51.45,0.0,46.84,1.0,46.84,51.45,51.45,0.0,50.73,7.95,3.34,7.98,6.2,1.7,15.02,1.73,0.46,6.95,14.27,0.12,0.0,0.19241 house060.xml,70.11,31.42,33.4,11.51,50.28,20.4,19.99,39.15,12.24,13.83,27.47,0.0,0.0,0.22938,87.06,15243.19,17324.29,1.0107,49.67,1.0,49.67,70.11,70.11,0.0,46.16,1.0,46.16,70.11,70.11,0.0,68.09,34.32,33.2,11.51,54.89,20.75,19.99,39.15,12.24,13.83,27.47,0.0,0.0,0.22938 house061.xml,62.05,6.35,3.02,5.79,10.12,1.84,6.81,9.3,0.47,4.66,9.07,0.18,0.0,0.22093,87.87,2936.84,3121.02,1.0709,56.83,1.0,56.83,62.05,62.05,0.0,57.79,1.0,57.79,62.05,62.05,0.0,63.57,5.62,3.08,5.79,8.96,1.85,6.8,9.3,0.47,4.66,9.07,0.18,0.0,0.22093 house062.xml,72.5,10.14,8.87,5.19,7.85,5.26,6.19,7.81,3.59,4.75,9.72,0.0,0.0,0.24634,73.0,4566.89,5880.46,1.0639,47.96,1.0,47.96,72.5,72.5,0.0,56.88,1.0,56.88,72.5,72.5,0.0,73.66,9.59,8.93,5.19,7.43,5.2,6.19,7.81,3.59,4.75,9.72,0.0,0.0,0.24634 @@ -68,15 +68,15 @@ house066.xml,73.73,11.64,30.47,7.53,8.71,18.07,8.76,5.71,12.54,6.43,17.87,3.66,0 house067.xml,60.3,14.92,36.48,7.53,23.9,22.17,14.13,14.64,12.87,7.79,19.7,0.54,0.0,0.29077,80.47,8345.59,10010.4,1.036,48.53,1.0,48.53,60.3,60.3,0.0,45.86,1.0,45.86,60.3,60.3,0.0,58.9,16.16,36.65,7.53,25.89,22.68,14.13,14.64,12.87,7.79,19.7,0.54,0.0,0.29077 house068.xml,72.96,24.45,50.52,7.53,39.17,30.7,14.5,26.75,17.35,10.95,26.97,5.51,0.0,0.24942,99.06,13055.08,13498.15,0.9763,50.05,1.0,50.05,72.96,72.96,0.0,47.11,1.0,47.11,72.96,72.96,0.0,69.54,28.089999999999996,51.11,7.53,45.0,32.2,14.5,26.75,17.35,10.95,26.97,5.51,0.0,0.24942 house069.xml,73.89,25.39,45.72,7.53,40.67,27.48,14.21,30.19,17.07,10.55,23.07,3.74,0.0,0.27113,102.61,12602.96,12402.76,0.9902,55.92,1.0,55.92,73.89,73.89,0.0,52.52,1.0,52.52,73.89,73.89,0.0,70.14,29.0,46.3,7.53,46.46,28.96,14.21,30.19,17.07,10.55,23.07,3.74,0.0,0.27113 -house070.xml,44.58,87.78,24.63,11.78,64.97,13.99,13.09,19.76,2.9,8.92,35.8,0.44,0.0,0.2016,46.53,7571.84,17120.03,0.9506,49.83,1.0,49.83,44.58,44.58,1.0,44.04,1.0,44.04,44.58,44.58,0.0,40.97,102.92,24.11,11.78,76.76,14.47,13.09,19.76,2.9,8.92,35.8,0.44,0.0,0.2016 -house071.xml,75.18,19.869999999999997,8.79,9.86,15.89,5.09,11.47,17.73,2.3,8.07,12.67,0.39,0.0,0.19769,76.48,4742.11,5894.44,1.0519,50.28,1.0,50.28,75.18,75.18,0.0,45.68,1.0,45.68,75.18,75.18,0.0,71.96,22.56,8.63,9.86,18.009999999999998,5.14,11.47,17.73,2.3,8.07,12.67,0.39,0.0,0.19769 -house072.xml,60.76,87.84,1.18,10.46,137.65,1.77,18.75,87.39,0.94,11.49,21.11,0.58,0.0,0.22826,155.21,16095.64,10548.92,0.9831,55.26,1.0,55.26,60.76,60.76,0.0,46.57,1.0,46.57,60.76,60.76,0.0,54.94,102.08,0.99,10.46,159.8,1.69,18.77,87.39,0.94,11.49,21.11,0.58,0.0,0.22826 +house070.xml,44.58,87.78,24.63,11.78,64.97,13.99,13.09,19.76,2.9,8.92,35.8,0.44,0.0,0.2016,46.53,7571.84,17120.03,0.9506,49.83,1.0,49.83,44.58,44.58,1.0,44.5,1.0,44.5,44.58,44.58,1.0,40.97,102.92,24.11,11.78,76.76,14.47,13.09,19.76,2.9,8.92,35.8,0.44,0.0,0.2016 +house071.xml,75.18,19.869999999999997,8.79,9.86,15.89,5.09,11.47,17.73,2.3,8.07,12.67,0.39,0.0,0.19769,76.48,4742.11,5894.44,1.0519,50.28,1.0,50.28,75.18,75.18,0.0,46.05,1.0,46.05,75.18,75.18,0.0,71.96,22.56,8.63,9.86,18.009999999999998,5.14,11.47,17.73,2.3,8.07,12.67,0.39,0.0,0.19769 +house072.xml,60.76,87.84,1.18,10.46,137.65,1.77,18.75,87.39,0.94,11.49,21.11,0.58,0.0,0.22826,155.21,16095.64,10548.92,0.9831,55.26,1.0,55.26,60.76,60.76,0.0,47.55,1.0,47.55,60.76,60.76,0.0,54.94,102.08,0.99,10.46,159.8,1.69,18.77,87.39,0.94,11.49,21.11,0.58,0.0,0.22826 house073.xml,32.21,116.93,26.53,11.78,96.39,15.100000000000001,26.8,23.39,14.030000000000001,32.43,44.5,3.05,0.0,0.16491,67.98,13476.31,20790.02,0.9535,48.23,1.0,48.23,53.85,53.85,0.0,45.32,1.0,45.32,53.85,53.85,0.0,46.33,133.6,26.09,11.78,110.37,15.6,26.83,23.39,14.030000000000001,32.43,44.5,3.05,0.0,0.16491 house074.xml,72.93,14.14,33.2,7.53,10.38,19.71,8.67,6.42,13.69,6.53,21.4,0.82,0.0,0.24152,74.46,7307.86,9326.17,1.0524,43.76,1.0,43.76,72.93,72.93,0.0,42.13,1.0,42.13,72.93,72.93,0.0,71.31,15.26,33.31,7.53,11.17,20.15,8.67,6.42,13.69,6.53,21.4,0.82,0.0,0.24152 house075.xml,64.6,31.66,15.74,11.39,50.6,10.09,19.41,31.37,5.42,18.5,17.85,0.0,0.0,0.21655,85.52,11426.32,12882.02,1.0371,46.25,1.0,46.25,64.6,64.6,0.0,43.48,1.0,43.48,64.6,64.6,0.0,61.45,35.58,15.7,11.39,56.86,10.3,19.42,31.37,5.42,18.5,17.85,0.0,0.0,0.21655 house076.xml,61.83,8.25,4.94,5.79,13.15,3.62,12.14,9.21,2.11,7.23,10.13,0.71,0.0,0.19763,104.4,3909.62,3521.5,1.0634,51.35,1.0,51.35,61.83,61.83,0.0,59.19,1.0,59.19,61.83,61.83,0.0,63.27,7.48,5.03,5.79,11.93,3.62,12.13,9.21,2.11,7.23,10.13,0.71,0.0,0.19763 house077.xml,70.86,12.3,5.04,8.66,19.69,3.63,9.54,9.25,2.02,7.33,9.98,7.89,0.0,0.22485,75.46,7512.85,9249.26,1.0764,53.91,1.0,53.91,70.86,70.86,0.0,49.57,1.0,49.57,70.86,70.86,0.0,74.21,10.24,5.28,8.66,16.38,3.7,9.53,9.25,2.02,7.33,9.98,7.89,0.0,0.22485 house078.xml,58.2,29.88,55.87,8.99,47.86,32.56,16.24,23.53,18.02,9.48,27.77,0.59,0.0,0.26263,79.64,11967.64,15219.45,0.9874,53.61,1.0,53.61,58.2,58.2,0.0,50.34,1.0,50.34,58.2,58.2,0.0,55.51,33.95,56.42,8.99,54.38,33.98,16.24,23.53,18.02,9.48,27.77,0.59,0.0,0.26263 -house079.xml,47.15,45.239999999999995,2.48,10.35,31.909999999999997,1.28,12.36,11.61,0.1,3.23,22.67,0.0,0.0,0.2156,47.43,2620.97,5688.7,0.9714,54.23,1.0,54.23,47.15,47.15,1.0,48.87,1.0,48.87,47.15,47.15,1.0,43.48,53.849999999999994,2.13,10.35,37.5,1.12,12.36,11.61,0.1,3.23,22.67,0.0,0.0,0.2156 +house079.xml,47.15,45.239999999999995,2.48,10.35,31.909999999999997,1.28,12.36,11.61,0.1,3.23,22.67,0.0,0.0,0.2156,47.43,2620.97,5688.7,0.9714,54.23,1.0,54.23,47.15,47.15,1.0,49.28,1.0,49.28,47.15,47.15,1.0,43.48,53.849999999999994,2.13,10.35,37.5,1.12,12.36,11.61,0.1,3.23,22.67,0.0,0.0,0.2156 house080.xml,41.28,31.22,62.34,8.99,22.939999999999998,37.25,10.83,6.52,12.879999999999999,1.82,23.91,1.35,0.0,0.27677,42.95,7039.43,16840.96,0.9732,45.67,1.0,45.67,41.28,41.28,1.0,44.1,1.0,44.1,41.28,41.28,1.0,39.11,36.31,63.17,8.99,26.33,39.349999999999994,10.84,6.52,12.879999999999999,1.82,23.91,1.35,0.0,0.27677 house081.xml,58.7,4.86,4.7,5.6,4.38,2.75,6.34,1.91,0.65,5.53,8.87,0.3,0.0,0.16758,61.72,2944.0,4194.6,1.1371,41.41,1.0,41.41,58.7,58.7,0.0,40.17,1.0,40.17,58.7,58.7,0.0,58.43,5.0,4.69,5.6,4.48,2.75,6.34,1.91,0.65,5.53,8.87,0.3,0.0,0.16758 diff --git a/workflow/tests/base_results/sample_files.csv b/workflow/tests/base_results/sample_files.csv index 883e7b7e8..ddbdf26e2 100644 --- a/workflow/tests/base_results/sample_files.csv +++ b/workflow/tests/base_results/sample_files.csv @@ -3,19 +3,19 @@ base-appliances-dehumidifier-ief-portable.xml,67.07,9.38,26.4,7.53,15.06,15.92,8 base-appliances-dehumidifier-ief-whole-home.xml,67.06,9.39,26.4,7.53,15.06,15.91,8.51,4.06,13.07,6.82,15.13,0.0,0.04,0.27126,70.41,5742.71,7604.38,1.0725,48.41,1.0,48.41,67.06,67.06,0.0,46.85,1.0,46.85,67.06,67.06,0.0,66.12,9.88,26.47,7.53,15.88,16.11,8.51,4.06,13.07,6.82,15.13,0.0,0.04,0.27126 base-appliances-dehumidifier-multiple.xml,67.07,9.42,26.42,7.53,15.09,15.91,8.51,4.06,13.07,6.82,15.13,0.0,0.03,0.27126,70.43,5742.61,7602.48,1.0725,48.19,1.0,48.19,67.07,67.07,0.0,46.33,1.0,46.33,67.07,67.07,0.0,66.1,9.93,26.51,7.53,15.91,16.12,8.51,4.06,13.07,6.82,15.13,0.0,0.03,0.27126 base-appliances-dehumidifier.xml,67.07,9.38,26.4,7.53,15.06,15.92,8.51,4.06,13.07,6.82,15.13,0.0,0.03,0.27126,70.42,5742.05,7602.91,1.0725,48.34,1.0,48.34,67.07,67.07,0.0,46.67,1.0,46.67,67.07,67.07,0.0,66.1,9.91,26.5,7.53,15.88,16.11,8.51,4.06,13.07,6.82,15.13,0.0,0.03,0.27126 -base-appliances-gas.xml,79.93,29.49,8.5,10.49,46.97,5.28,11.52,38.93,5.29,9.17,23.34,0.0,0.0,0.21523,161.85,9054.05,5537.46,1.0102,57.1,1.0,57.1,79.93,79.93,0.0,49.89,1.0,49.89,79.93,79.93,0.0,76.0,33.61,8.39,10.49,53.52,5.23,11.53,38.93,5.29,9.17,23.34,0.0,0.0,0.21523 -base-appliances-modified.xml,80.25,29.96,8.29,10.49,47.71,5.17,11.52,39.5,5.19,9.7,21.6,0.0,0.0,0.22114,155.53,8703.0,5537.46,1.0105,56.54,1.0,56.54,80.25,80.25,0.0,49.08,1.0,49.08,80.25,80.25,0.0,76.19,34.08,8.18,10.49,54.27,5.12,11.53,39.5,5.19,9.7,21.6,0.0,0.0,0.22114 -base-appliances-none.xml,81.3,29.96,8.29,10.49,47.71,5.17,11.52,39.37,5.21,9.61,22.52,0.0,0.0,0.22114,156.37,8750.28,5537.46,1.0105,56.29,1.0,56.29,81.3,81.3,0.0,48.86,1.0,48.86,81.3,81.3,0.0,77.19,34.08,8.18,10.49,54.27,5.12,11.53,39.37,5.21,9.61,22.52,0.0,0.0,0.22114 -base-appliances-oil.xml,79.93,29.49,8.5,10.49,46.97,5.28,11.52,38.93,5.29,9.17,23.34,0.0,0.0,0.21523,166.07,9290.54,5537.46,1.0102,57.1,1.0,57.1,79.93,79.93,0.0,49.89,1.0,49.89,79.93,79.93,0.0,76.0,33.61,8.39,10.49,53.52,5.23,11.53,38.93,5.29,9.17,23.34,0.0,0.0,0.21523 -base-appliances-propane.xml,79.93,29.49,8.5,10.49,46.97,5.28,11.52,38.93,5.29,9.17,23.34,0.0,0.0,0.21523,164.5,9202.46,5537.46,1.0102,57.1,1.0,57.1,79.93,79.93,0.0,49.89,1.0,49.89,79.93,79.93,0.0,76.0,33.61,8.39,10.49,53.52,5.23,11.53,38.93,5.29,9.17,23.34,0.0,0.0,0.21523 -base-appliances-wood.xml,79.93,29.49,8.5,10.49,46.97,5.28,11.52,38.93,5.29,9.17,23.34,0.0,0.0,0.21523,,,,,57.1,1.0,57.1,79.93,79.93,0.0,49.89,1.0,49.89,79.93,79.93,0.0,76.0,33.61,8.39,10.49,53.52,5.23,11.53,38.93,5.29,9.17,23.34,0.0,0.0,0.21523 -base-atticroof-cathedral.xml,72.44,32.81,8.5,10.49,52.25,5.12,11.53,35.57,4.56,9.17,21.28,0.0,0.0,0.1982,138.7,8026.23,5732.74,1.0094,55.25,1.0,55.25,72.44,72.44,0.0,49.36,1.0,49.36,72.44,72.44,0.0,67.58,38.66,8.36,10.49,61.56,5.03,11.53,35.57,4.56,9.17,21.28,0.0,0.0,0.1982 -base-atticroof-conditioned.xml,78.4,37.88,10.72,10.49,60.33,6.33,11.52,47.36,5.29,9.07,25.37,0.0,0.0,0.21304,156.18,10108.43,6644.47,0.9741,57.13,1.0,57.13,78.4,78.4,0.0,49.34,1.0,49.34,78.4,78.4,0.0,72.05,46.25,10.55,10.49,73.67,6.17,11.53,47.36,5.29,9.07,25.37,0.0,0.0,0.21304 -base-atticroof-flat.xml,71.86,29.73,8.57,10.49,47.35,5.17,11.52,32.56,4.03,9.17,21.28,0.0,0.0,0.19778,135.13,7550.12,5535.31,1.0094,56.27,1.0,56.27,71.86,71.86,0.0,48.86,1.0,48.86,71.86,71.86,0.0,68.33,33.85,8.44,10.49,53.91,5.07,11.53,32.56,4.03,9.17,21.28,0.0,0.0,0.19778 +base-appliances-gas.xml,79.93,29.49,8.5,10.49,46.97,5.28,11.52,38.93,5.29,9.17,23.34,0.0,0.0,0.21523,161.85,9054.05,5537.46,1.0102,57.1,1.0,57.1,79.93,79.93,0.0,50.72,1.0,50.72,79.93,79.93,0.0,76.0,33.61,8.39,10.49,53.52,5.23,11.53,38.93,5.29,9.17,23.34,0.0,0.0,0.21523 +base-appliances-modified.xml,80.25,29.96,8.29,10.49,47.71,5.17,11.52,39.5,5.19,9.7,21.6,0.0,0.0,0.22114,155.53,8703.0,5537.46,1.0105,56.54,1.0,56.54,80.25,80.25,0.0,49.94,1.0,49.94,80.25,80.25,0.0,76.19,34.08,8.18,10.49,54.27,5.12,11.53,39.5,5.19,9.7,21.6,0.0,0.0,0.22114 +base-appliances-none.xml,81.3,29.96,8.29,10.49,47.71,5.17,11.52,39.37,5.21,9.61,22.52,0.0,0.0,0.22114,156.37,8750.28,5537.46,1.0105,56.29,1.0,56.29,81.3,81.3,0.0,49.72,1.0,49.72,81.3,81.3,0.0,77.19,34.08,8.18,10.49,54.27,5.12,11.53,39.37,5.21,9.61,22.52,0.0,0.0,0.22114 +base-appliances-oil.xml,79.93,29.49,8.5,10.49,46.97,5.28,11.52,38.93,5.29,9.17,23.34,0.0,0.0,0.21523,166.07,9290.54,5537.46,1.0102,57.1,1.0,57.1,79.93,79.93,0.0,50.72,1.0,50.72,79.93,79.93,0.0,76.0,33.61,8.39,10.49,53.52,5.23,11.53,38.93,5.29,9.17,23.34,0.0,0.0,0.21523 +base-appliances-propane.xml,79.93,29.49,8.5,10.49,46.97,5.28,11.52,38.93,5.29,9.17,23.34,0.0,0.0,0.21523,164.5,9202.46,5537.46,1.0102,57.1,1.0,57.1,79.93,79.93,0.0,50.72,1.0,50.72,79.93,79.93,0.0,76.0,33.61,8.39,10.49,53.52,5.23,11.53,38.93,5.29,9.17,23.34,0.0,0.0,0.21523 +base-appliances-wood.xml,79.93,29.49,8.5,10.49,46.97,5.28,11.52,38.93,5.29,9.17,23.34,0.0,0.0,0.21523,,,,,57.1,1.0,57.1,79.93,79.93,0.0,50.72,1.0,50.72,79.93,79.93,0.0,76.0,33.61,8.39,10.49,53.52,5.23,11.53,38.93,5.29,9.17,23.34,0.0,0.0,0.21523 +base-atticroof-cathedral.xml,72.44,32.81,8.5,10.49,52.25,5.12,11.53,35.57,4.56,9.17,21.28,0.0,0.0,0.1982,138.7,8026.23,5732.74,1.0094,55.25,1.0,55.25,72.44,72.44,0.0,50.04,1.0,50.04,72.44,72.44,0.0,67.58,38.66,8.36,10.49,61.56,5.03,11.53,35.57,4.56,9.17,21.28,0.0,0.0,0.1982 +base-atticroof-conditioned.xml,78.4,37.88,10.72,10.49,60.33,6.33,11.52,47.36,5.29,9.07,25.37,0.0,0.0,0.21304,156.18,10108.43,6644.47,0.9741,57.13,1.0,57.13,78.4,78.4,0.0,50.27,1.0,50.27,78.4,78.4,0.0,72.05,46.25,10.55,10.49,73.67,6.17,11.53,47.36,5.29,9.07,25.37,0.0,0.0,0.21304 +base-atticroof-flat.xml,71.86,29.73,8.57,10.49,47.35,5.17,11.52,32.56,4.03,9.17,21.28,0.0,0.0,0.19778,135.13,7550.12,5535.31,1.0094,56.27,1.0,56.27,71.86,71.86,0.0,49.71,1.0,49.71,71.86,71.86,0.0,68.33,33.85,8.44,10.49,53.91,5.07,11.53,32.56,4.03,9.17,21.28,0.0,0.0,0.19778 base-atticroof-radiant-barrier.xml,73.1,9.51,26.3,7.53,15.24,15.86,8.51,7.02,14.06,6.83,15.13,0.0,0.0,0.22591,78.94,6338.29,7574.5,1.06,47.17,1.0,47.17,73.1,73.1,0.0,44.36,1.0,44.36,73.1,73.1,0.0,72.11,10.03,26.36,7.53,16.06,16.05,8.51,7.02,14.06,6.83,15.13,0.0,0.0,0.22591 -base-atticroof-unvented-insulated-roof.xml,74.47,29.96,8.29,10.49,47.71,5.17,11.52,35.61,4.27,9.17,21.28,0.0,0.0,0.18672,143.3,8005.4,5537.46,1.0089,56.29,1.0,56.29,74.47,74.47,0.0,48.86,1.0,48.86,74.47,74.47,0.0,70.71,34.08,8.18,10.49,54.27,5.12,11.53,35.61,4.27,9.17,21.28,0.0,0.0,0.18672 -base-atticroof-vented.xml,76.9,30.49,8.08,10.49,48.56,5.07,11.83,39.02,4.48,9.33,21.28,0.0,0.0,0.22147,150.99,8528.22,5589.08,1.0105,57.05,1.0,57.05,76.9,76.9,0.0,50.01,1.0,50.01,76.9,76.9,0.0,73.01,34.63,7.97,10.49,55.15,5.02,11.83,39.02,4.48,9.33,21.28,0.0,0.0,0.22147 -base-bldgtype-attached.xml,74.98,19.22,5.73,10.49,30.63,3.89,11.52,24.16,3.31,9.45,17.18,0.0,0.0,0.22114,134.28,5969.43,4280.89,1.0385,55.08,1.0,55.08,74.98,74.98,0.0,48.04,1.0,48.04,74.98,74.98,0.0,73.09,20.74,5.68,10.49,33.04,3.86,11.52,24.16,3.31,9.45,17.18,0.0,0.0,0.22114 +base-atticroof-unvented-insulated-roof.xml,74.47,29.96,8.29,10.49,47.71,5.17,11.52,35.61,4.27,9.17,21.28,0.0,0.0,0.18672,143.3,8005.4,5537.46,1.0089,56.29,1.0,56.29,74.47,74.47,0.0,49.72,1.0,49.72,74.47,74.47,0.0,70.71,34.08,8.18,10.49,54.27,5.12,11.53,35.61,4.27,9.17,21.28,0.0,0.0,0.18672 +base-atticroof-vented.xml,76.9,30.49,8.08,10.49,48.56,5.07,11.83,39.02,4.48,9.33,21.28,0.0,0.0,0.22147,150.99,8528.22,5589.08,1.0105,57.05,1.0,57.05,76.9,76.9,0.0,50.83,1.0,50.83,76.9,76.9,0.0,73.01,34.63,7.97,10.49,55.15,5.02,11.83,39.02,4.48,9.33,21.28,0.0,0.0,0.22147 +base-bldgtype-attached.xml,74.98,19.22,5.73,10.49,30.63,3.89,11.52,24.16,3.31,9.45,17.18,0.0,0.0,0.22114,134.28,5969.43,4280.89,1.0385,55.08,1.0,55.08,74.98,74.98,0.0,48.88,1.0,48.88,74.98,74.98,0.0,73.09,20.74,5.68,10.49,33.04,3.86,11.52,24.16,3.31,9.45,17.18,0.0,0.0,0.22114 base-bldgtype-multifamily-adjacent-to-multiple.xml,68.53,10.48,5.02,10.49,16.75,3.5,11.52,11.19,2.39,9.73,13.08,0.0,0.0,0.22967,103.61,3675.08,3249.48,1.0915,65.31,1.0,65.31,68.53,68.53,0.0,63.39,1.0,63.39,68.53,68.53,0.0,71.01,8.94,5.1,10.49,14.29,3.54,11.51,11.19,2.39,9.73,13.08,0.0,0.0,0.22967 base-bldgtype-multifamily-location-portland-or.xml,68.79,5.07,3.41,9.98,8.12,2.46,10.99,1.75,2.52,9.25,13.08,0.0,0.0,0.19662,75.86,2266.34,2771.73,1.0779,61.01,1.0,61.01,68.79,68.79,0.0,58.47,1.0,58.47,68.79,68.79,0.0,70.86,3.85,3.79,9.98,6.18,2.62,10.99,1.75,2.52,9.25,13.08,0.0,0.0,0.19662 base-bldgtype-multifamily-shared-boiler-only-baseboard.xml,65.97,7.81,5.71,10.49,12.77,3.84,11.51,3.21,3.78,9.7,13.08,0.0,0.0,0.23825,74.31,2603.94,3199.61,1.0951,57.89,1.0,57.89,65.97,65.97,0.0,56.69,1.0,56.69,65.97,65.97,0.0,68.21,6.39,5.87,10.49,10.48,3.9,11.5,3.21,3.78,9.7,13.08,0.0,0.0,0.23825 @@ -37,136 +37,136 @@ base-bldgtype-multifamily-shared-pv.xml,6.08,7.8,5.71,10.49,12.47,3.82,11.51,3.0 base-bldgtype-multifamily-shared-water-heater-recirc.xml,61.93,7.21,6.1,10.49,11.52,3.99,18.21,3.07,3.0,13.63,13.08,0.0,0.0,0.22939,108.79,3684.13,3102.74,1.0914,50.89,1.0,50.89,61.93,61.93,0.0,56.32,1.0,56.32,61.93,61.93,0.0,63.95,5.83,6.28,10.49,9.33,4.07,18.19,3.07,3.0,13.63,13.08,0.0,0.0,0.22939 base-bldgtype-multifamily-shared-water-heater.xml,60.5,7.21,6.1,10.49,11.52,3.99,18.21,3.07,3.0,12.54,13.08,0.0,0.0,0.22939,106.19,3595.91,3102.74,1.0914,50.06,1.0,50.06,60.5,60.5,0.0,55.31,1.0,55.31,60.5,60.5,0.0,62.47,5.83,6.28,10.49,9.33,4.07,18.19,3.07,3.0,12.54,13.08,0.0,0.0,0.22939 base-bldgtype-multifamily.xml,63.65,7.8,5.71,10.49,12.47,3.82,11.51,3.0,3.03,9.7,13.08,0.0,0.0,0.22967,74.4,2519.75,3102.74,1.0915,56.31,1.0,56.31,63.65,63.65,0.0,55.55,1.0,55.55,63.65,63.65,0.0,65.8,6.39,5.87,10.49,10.22,3.88,11.5,3.0,3.03,9.7,13.08,0.0,0.0,0.22967 -base-dhw-combi-tankless.xml,64.76,29.23,8.57,10.49,47.84,5.37,18.31,32.66,4.78,10.47,21.28,0.0,0.0,0.22999,147.08,8447.62,5681.45,1.011,54.88,1.0,54.88,64.76,64.76,0.0,48.39,1.0,48.39,64.76,64.76,0.0,61.54,33.33,8.45,10.49,54.39,5.32,18.32,32.66,4.78,10.47,21.28,0.0,0.0,0.22999 -base-dhw-desuperheater.xml,83.81,29.96,8.29,10.49,47.71,5.23,11.52,44.9,5.44,7.04,21.28,0.0,0.0,0.22161,161.47,9270.88,5681.45,1.0106,71.26,1.0,71.26,83.81,83.81,0.0,58.28,1.0,58.28,83.81,83.81,0.0,79.56,34.08,8.18,10.49,54.27,5.19,11.53,44.9,5.44,7.04,21.28,0.0,0.0,0.22161 -base-dhw-dwhr.xml,76.58,29.96,8.29,10.49,47.71,5.17,11.52,39.56,5.17,6.93,21.28,0.0,0.0,0.22114,151.23,8462.37,5537.46,1.0105,56.29,1.0,56.29,76.58,76.58,0.0,48.86,1.0,48.86,76.58,76.58,0.0,72.71,34.08,8.18,10.49,54.27,5.12,11.53,39.56,5.17,6.93,21.28,0.0,0.0,0.22114 -base-dhw-indirect-standbyloss.xml,68.67,29.14,8.6,10.49,47.71,5.39,18.65,30.97,5.08,14.25,21.28,0.0,0.0,0.22505,152.43,8778.1,5697.86,1.0107,54.88,1.0,54.88,68.67,68.67,0.0,48.39,1.0,48.39,68.67,68.67,0.0,65.24,33.24,8.48,10.49,54.25,5.34,18.66,30.97,5.08,14.25,21.28,0.0,0.0,0.22505 -base-dhw-jacket-gas.xml,79.34,29.14,8.6,10.49,46.41,5.33,18.65,38.69,5.3,14.42,21.28,0.0,0.0,0.21601,176.65,9912.5,5554.21,1.0103,53.97,1.0,53.97,79.34,79.34,0.0,46.59,1.0,46.59,79.34,79.34,0.0,75.34,33.24,8.48,10.49,52.94,5.27,18.66,38.69,5.3,14.42,21.28,0.0,0.0,0.21601 -base-dhw-jacket-hpwh.xml,75.21,29.48,8.47,10.49,46.94,5.26,12.42,44.49,4.56,3.42,21.28,0.0,0.0,0.21121,156.75,8853.21,5591.67,1.0101,56.59,1.0,56.59,75.21,75.21,0.0,49.15,1.0,49.15,75.21,75.21,0.0,71.42,33.58,8.36,10.49,53.48,5.21,12.42,44.49,4.56,3.42,21.28,0.0,0.0,0.21121 -base-dhw-jacket-indirect.xml,67.56,29.14,8.6,10.49,47.71,5.39,18.65,31.46,4.99,13.28,21.28,0.0,0.0,0.22505,151.08,8700.71,5697.86,1.0107,54.88,1.0,54.88,67.56,67.56,0.0,48.39,1.0,48.39,67.56,67.56,0.0,64.19,33.24,8.48,10.49,54.25,5.34,18.66,31.46,4.99,13.28,21.28,0.0,0.0,0.22505 -base-dhw-low-flow-fixtures.xml,78.79,29.96,8.29,10.49,47.71,5.17,11.52,39.56,5.17,8.8,21.28,0.0,0.0,0.22114,153.91,8612.38,5537.46,1.0105,56.29,1.0,56.29,78.79,78.79,0.0,48.86,1.0,48.86,78.79,78.79,0.0,74.81,34.08,8.18,10.49,54.27,5.12,11.53,39.56,5.17,8.8,21.28,0.0,0.0,0.22114 -base-dhw-multiple.xml,67.77,29.96,8.29,10.5,48.99,5.23,11.5,31.66,4.96,6.0600000000000005,21.28,0.0,0.0,0.23051,131.15,7533.13,5681.6,1.011,61.27,1.0,61.27,67.77,67.77,0.0,54.52,1.0,54.52,67.77,67.77,0.0,64.39,34.08,8.18,10.5,55.57,5.19,11.54,31.66,4.96,6.0600000000000005,21.28,0.0,0.0,0.23051 -base-dhw-none.xml,83.4,29.23,8.57,10.49,46.55,5.31,18.31,38.16,5.38,18.3,22.38,0.0,0.0,0.22089,187.63,10499.27,5537.46,1.0105,61.22,1.0,61.22,83.4,83.4,0.0,54.72,1.0,54.72,83.4,83.4,0.0,79.19,33.33,8.45,10.49,53.07,5.25,18.32,38.16,5.38,18.3,22.38,0.0,0.0,0.22089 -base-dhw-recirc-demand.xml,79.17,29.96,8.29,10.49,47.71,5.17,11.52,39.56,5.17,9.12,21.28,0.0,0.0,0.22114,154.36,8637.75,5537.46,1.0105,56.29,1.0,56.29,79.17,79.17,0.0,48.86,1.0,48.86,79.17,79.17,0.0,75.17,34.08,8.18,10.49,54.27,5.12,11.53,39.56,5.17,9.12,21.28,0.0,0.0,0.22114 -base-dhw-solar-fraction.xml,72.31,29.96,8.29,10.49,47.71,5.17,11.52,39.86,5.13,3.21,21.28,0.0,0.0,0.22114,146.6,8203.51,5537.46,1.0105,56.29,1.0,56.29,72.31,72.31,0.0,48.86,1.0,48.86,72.31,72.31,0.0,68.65,34.08,8.18,10.49,54.27,5.12,11.53,39.86,5.13,3.21,21.28,0.0,0.0,0.22114 -base-dhw-solar-indirect-flat-plate.xml,70.53,29.96,8.29,10.49,47.71,5.17,11.52,39.15,5.34,1.8,21.28,0.0,0.0,0.22114,143.1,8007.73,5537.46,1.0105,56.29,1.0,56.29,70.53,70.53,0.0,48.86,1.0,48.86,70.53,70.53,0.0,66.96,34.08,8.18,10.49,54.27,5.12,11.53,39.15,5.34,1.8,21.28,0.0,0.0,0.22114 -base-dhw-tank-elec-uef.xml,79.24,30.03,8.26,10.49,47.83,5.16,11.39,39.5,5.18,9.24,21.28,0.0,0.0,0.22269,154.63,8640.3,5528.96,1.0106,56.51,1.0,56.51,79.24,79.24,0.0,49.06,1.0,49.06,79.24,79.24,0.0,75.24,34.16,8.15,10.49,54.4,5.11,11.39,39.5,5.18,9.24,21.28,0.0,0.0,0.22269 -base-dhw-tank-gas-uef.xml,79.48,29.38,8.51,10.49,46.8,5.28,17.66,38.56,5.32,14.94,21.28,0.0,0.0,0.23022,178.38,9970.67,5528.96,1.011,53.97,1.0,53.97,79.48,79.48,0.0,46.59,1.0,46.59,79.48,79.48,0.0,75.47,33.49,8.39,10.49,53.33,5.22,17.67,38.56,5.32,14.94,21.28,0.0,0.0,0.23022 -base-dhw-tank-heat-pump-uef.xml,74.26,29.8,8.35,10.49,47.46,5.2,11.81,45.4,4.44,2.43,21.28,0.0,0.0,0.21797,158.62,8901.69,5554.21,1.0104,56.31,1.0,56.31,74.26,74.26,0.0,48.93,1.0,48.93,74.26,74.26,0.0,70.51,33.92,8.23,10.49,54.02,5.15,11.81,45.4,4.44,2.43,21.28,0.0,0.0,0.21797 -base-dhw-tank-oil.xml,79.96,29.14,8.6,10.49,46.41,5.33,18.65,38.25,5.36,15.51,21.28,0.0,0.0,0.21601,191.9,10767.88,5554.21,1.0103,53.97,1.0,53.97,79.96,79.96,0.0,46.59,1.0,46.59,79.96,79.96,0.0,75.92,33.24,8.48,10.49,52.94,5.27,18.66,38.25,5.36,15.51,21.28,0.0,0.0,0.21601 -base-dhw-tank-wood.xml,79.96,29.14,8.6,10.49,46.41,5.33,18.65,38.25,5.36,15.51,21.28,0.0,0.0,0.21601,,,,,53.97,1.0,53.97,79.96,79.96,0.0,46.59,1.0,46.59,79.96,79.96,0.0,75.92,33.24,8.48,10.49,52.94,5.27,18.66,38.25,5.36,15.51,21.28,0.0,0.0,0.21601 -base-dhw-tankless-electric-uef.xml,79.62,29.96,8.29,10.49,47.71,5.17,11.52,40.02,5.11,9.33,21.28,0.0,0.0,0.22114,155.73,8714.44,5537.46,1.0105,56.43,1.0,56.43,79.62,79.62,0.0,48.99,1.0,48.99,79.62,79.62,0.0,75.6,34.08,8.18,10.49,54.27,5.12,11.53,40.02,5.11,9.33,21.28,0.0,0.0,0.22114 -base-dhw-tankless-gas-uef.xml,72.84,29.23,8.57,10.49,46.55,5.31,18.31,40.02,5.11,9.83,21.28,0.0,0.0,0.22089,168.27,9415.62,5537.46,1.0105,53.97,1.0,53.97,72.84,72.84,0.0,46.59,1.0,46.59,72.84,72.84,0.0,69.16,33.33,8.45,10.49,53.07,5.25,18.32,40.02,5.11,9.83,21.28,0.0,0.0,0.22089 -base-dhw-tankless-propane.xml,75.2,29.23,8.57,10.49,46.55,5.31,18.31,40.02,5.11,11.39,21.28,0.0,0.0,0.22089,178.58,9992.95,5537.46,1.0105,53.97,1.0,53.97,75.2,75.2,0.0,46.59,1.0,46.59,75.2,75.2,0.0,71.4,33.33,8.45,10.49,53.07,5.25,18.32,40.02,5.11,11.39,21.28,0.0,0.0,0.22089 -base-enclosure-2stories-garage.xml,77.5,39.42,10.45,10.49,62.79,6.17,11.52,42.98,7.17,9.13,23.92,0.0,0.0,0.22114,147.3,9509.26,6588.8,0.9798,56.08,1.0,56.08,77.5,77.5,0.0,49.42,1.0,49.42,77.5,77.5,0.0,70.92,48.01,10.33,10.49,76.46,6.1,11.53,42.98,7.17,9.13,23.92,0.0,0.0,0.22114 -base-enclosure-2stories.xml,77.46,46.06,12.1,10.49,73.37,7.03,11.53,52.05,6.94,9.01,27.42,0.0,0.0,0.22114,153.66,11091.72,7476.66,0.9654,55.74,1.0,55.74,77.46,77.46,0.0,48.92,1.0,48.92,77.46,77.46,0.0,71.03,55.72,11.97,10.49,88.75,6.91,11.53,52.05,6.94,9.01,27.42,0.0,0.0,0.22114 -base-enclosure-beds-1.xml,83.92,29.61,7.66,6.16,47.15,4.78,7.19,41.78,4.82,5.56,19.85,0.0,0.0,0.22136,174.69,8534.08,4986.52,0.9797,57.84,1.0,57.84,83.92,83.92,0.0,50.9,1.0,50.9,83.92,83.92,0.0,79.24,33.73,7.56,6.16,53.72,4.74,7.19,41.78,4.82,5.56,19.85,0.0,0.0,0.22136 -base-enclosure-beds-2.xml,81.42,29.78,7.97,8.39,47.43,5.0,9.42,40.68,5.0,7.4,20.56,0.0,0.0,0.22124,164.09,8592.24,5262.04,0.9951,57.02,1.0,57.02,81.42,81.42,0.0,49.82,1.0,49.82,81.42,81.42,0.0,77.22,33.91,7.87,8.39,54.0,4.9,9.42,40.68,5.0,7.4,20.56,0.0,0.0,0.22124 -base-enclosure-beds-4.xml,77.05,30.14,8.6,12.54,47.99,5.4,13.57,38.41,5.34,10.9,21.99,0.0,0.0,0.22104,145.87,8684.2,5802.75,1.0259,55.45,1.0,55.45,77.05,77.05,0.0,47.85,1.0,47.85,77.05,77.05,0.0,73.44,34.25,8.49,12.54,54.55,5.29,13.57,38.41,5.34,10.9,21.99,0.0,0.0,0.22104 -base-enclosure-beds-5.xml,75.18,30.32,8.93,14.54,48.29,5.55,15.57,37.27,5.51,12.6,22.7,0.0,0.0,0.22096,138.16,8725.71,6064.75,1.0413,54.69,1.0,54.69,75.18,75.18,0.0,46.97,1.0,46.97,75.18,75.18,0.0,71.67,34.43,8.8,14.54,54.83,5.51,15.57,37.27,5.51,12.6,22.7,0.0,0.0,0.22096 -base-enclosure-garage.xml,77.66,29.93,6.76,10.49,47.68,4.45,11.73,41.31,3.32,9.26,21.42,0.0,0.0,0.22114,157.57,8790.53,5520.75,1.0105,56.92,1.0,56.92,77.66,77.66,0.0,49.42,1.0,49.42,77.66,77.66,0.0,73.58,34.1,6.68,10.49,54.31,4.44,11.73,41.31,3.32,9.26,21.42,0.0,0.0,0.22114 -base-enclosure-infil-ach-house-pressure.xml,79.23,29.96,8.29,10.49,47.71,5.17,11.52,39.56,5.17,9.17,21.28,0.0,0.0,0.22114,154.43,8641.78,5537.46,1.0105,56.29,1.0,56.29,79.23,79.23,0.0,48.86,1.0,48.86,79.23,79.23,0.0,75.23,34.08,8.18,10.49,54.27,5.12,11.53,39.56,5.17,9.17,21.28,0.0,0.0,0.22114 -base-enclosure-infil-cfm-house-pressure.xml,79.23,29.96,8.29,10.49,47.71,5.17,11.52,39.56,5.17,9.17,21.28,0.0,0.0,0.22114,154.43,8641.78,5537.46,1.0105,56.29,1.0,56.29,79.23,79.23,0.0,48.86,1.0,48.86,79.23,79.23,0.0,75.23,34.08,8.18,10.49,54.27,5.12,11.53,39.56,5.17,9.17,21.28,0.0,0.0,0.22114 -base-enclosure-infil-cfm50.xml,79.23,29.96,8.29,10.49,47.71,5.17,11.52,39.56,5.17,9.17,21.28,0.0,0.0,0.22114,154.43,8641.78,5537.46,1.0105,56.29,1.0,56.29,79.23,79.23,0.0,48.86,1.0,48.86,79.23,79.23,0.0,75.23,34.08,8.18,10.49,54.27,5.12,11.53,39.56,5.17,9.17,21.28,0.0,0.0,0.22114 -base-enclosure-infil-ela.xml,79.23,29.96,8.29,10.49,47.71,5.17,11.52,39.56,5.17,9.17,21.28,0.0,0.0,0.22114,154.43,8641.78,5537.46,1.0105,56.29,1.0,56.29,79.23,79.23,0.0,48.86,1.0,48.86,79.23,79.23,0.0,75.23,34.08,8.18,10.49,54.27,5.12,11.53,39.56,5.17,9.17,21.28,0.0,0.0,0.22114 -base-enclosure-infil-natural-ach.xml,79.23,29.96,8.29,10.49,47.71,5.17,11.52,39.56,5.17,9.17,21.28,0.0,0.0,0.22114,154.43,8641.78,5537.46,1.0105,56.29,1.0,56.29,79.23,79.23,0.0,48.86,1.0,48.86,79.23,79.23,0.0,75.23,34.08,8.18,10.49,54.27,5.12,11.53,39.56,5.17,9.17,21.28,0.0,0.0,0.22114 -base-enclosure-infil-natural-cfm.xml,79.23,29.96,8.29,10.49,47.71,5.17,11.52,39.56,5.17,9.17,21.28,0.0,0.0,0.22114,154.43,8641.78,5537.46,1.0105,56.29,1.0,56.29,79.23,79.23,0.0,48.86,1.0,48.86,79.23,79.23,0.0,75.23,34.08,8.18,10.49,54.27,5.12,11.53,39.56,5.17,9.17,21.28,0.0,0.0,0.22114 -base-enclosure-overhangs.xml,79.25,29.96,8.29,10.49,47.71,5.17,11.52,40.07,5.0,9.17,21.28,0.0,0.0,0.22114,155.54,8703.66,5537.46,1.0105,56.29,1.0,56.29,79.25,79.25,0.0,48.86,1.0,48.86,79.25,79.25,0.0,75.25,34.08,8.18,10.49,54.27,5.12,11.53,40.07,5.0,9.17,21.28,0.0,0.0,0.22114 -base-enclosure-skylights.xml,79.71,29.96,8.29,10.49,47.71,5.17,11.52,37.9,5.98,9.17,21.28,0.0,0.0,0.20156,151.46,8467.67,5537.46,1.0096,56.29,1.0,56.29,79.71,79.71,0.0,48.86,1.0,48.86,79.71,79.71,0.0,75.68,34.08,8.18,10.49,54.27,5.12,11.53,37.9,5.98,9.17,21.28,0.0,0.0,0.20156 -base-foundation-ambient.xml,80.36,19.39,7.08,10.49,30.93,4.56,11.52,25.89,5.89,9.36,15.13,0.0,0.0,0.22114,141.52,6210.31,4144.84,1.0587,54.86,1.0,54.86,80.36,80.36,0.0,47.89,1.0,47.89,80.36,80.36,0.0,78.16,20.99,7.03,10.49,33.5,4.53,11.52,25.89,5.89,9.36,15.13,0.0,0.0,0.22114 -base-foundation-basement-garage.xml,76.72,26.96,7.08,10.49,42.93,4.57,11.53,32.65,5.29,9.41,17.78,0.0,0.0,0.22114,145.37,7378.17,4905.14,1.0347,55.16,1.0,55.16,76.72,76.72,0.0,48.33,1.0,48.33,76.72,76.72,0.0,73.7,29.88,7.0,10.49,47.59,4.48,11.53,32.65,5.29,9.41,17.78,0.0,0.0,0.22114 -base-foundation-conditioned-basement-slab-insulation.xml,78.72,29.96,8.29,10.49,47.71,5.17,11.52,38.23,5.42,9.17,21.28,0.0,0.0,0.22114,151.31,8466.7,5537.46,1.0105,56.29,1.0,56.29,78.72,78.72,0.0,48.86,1.0,48.86,78.72,78.72,0.0,74.75,34.08,8.18,10.49,54.27,5.12,11.53,38.23,5.42,9.17,21.28,0.0,0.0,0.22114 -base-foundation-conditioned-basement-wall-insulation.xml,79.31,28.53,7.91,10.49,45.44,4.99,11.52,38.61,4.71,9.17,21.28,0.0,0.0,0.22114,154.17,8468.18,5435.65,1.0105,57.22,1.0,57.22,79.31,79.31,0.0,49.58,1.0,49.58,79.31,79.31,0.0,75.22,32.65,7.81,10.49,51.99,4.94,11.53,38.61,4.71,9.17,21.28,0.0,0.0,0.22114 -base-foundation-multiple.xml,73.41,19.36,6.44,10.49,30.9,4.25,11.67,20.77,5.04,9.32,15.13,0.0,0.0,0.22114,123.57,5396.3,4124.85,1.0587,54.37,1.0,54.37,73.41,73.41,0.0,47.58,1.0,47.58,73.41,73.41,0.0,71.34,20.98,6.4,10.49,33.49,4.24,11.67,20.77,5.04,9.32,15.13,0.0,0.0,0.22114 -base-foundation-slab.xml,66.06,21.07,6.59,10.49,33.56,4.32,11.52,16.69,4.46,9.36,15.13,0.0,0.0,0.22114,107.34,4764.04,4191.91,1.0587,53.93,1.0,53.93,66.06,66.06,0.0,47.12,1.0,47.12,66.06,66.06,0.0,64.27,22.69,6.53,10.49,36.15,4.29,11.53,16.69,4.46,9.36,15.13,0.0,0.0,0.22114 -base-foundation-unconditioned-basement-assembly-r.xml,70.86,19.28,6.6,10.49,30.77,4.34,11.67,19.5,4.53,9.34,15.13,0.0,0.0,0.22114,118.57,5176.83,4123.9,1.0587,53.79,1.0,53.79,70.86,70.86,0.0,47.11,1.0,47.11,70.86,70.86,0.0,68.87,20.91,6.56,10.49,33.37,4.32,11.67,19.5,4.53,9.34,15.13,0.0,0.0,0.22114 -base-foundation-unconditioned-basement-wall-insulation.xml,77.87,19.28,6.6,10.49,30.77,4.34,11.67,27.51,4.23,9.28,15.13,0.0,0.0,0.22114,144.8,6322.31,4123.9,1.0587,53.79,1.0,53.79,77.87,77.87,0.0,47.11,1.0,47.11,77.87,77.87,0.0,75.69,20.91,6.56,10.49,33.37,4.32,11.67,27.51,4.23,9.28,15.13,0.0,0.0,0.22114 -base-foundation-unconditioned-basement.xml,73.66,19.28,6.6,10.49,30.77,4.34,11.67,20.97,5.06,9.34,15.13,0.0,0.0,0.22114,124.33,5428.59,4123.9,1.0587,53.79,1.0,53.79,73.66,73.66,0.0,47.11,1.0,47.11,73.66,73.66,0.0,71.6,20.91,6.56,10.49,33.37,4.32,11.67,20.97,5.06,9.34,15.13,0.0,0.0,0.22114 -base-foundation-unvented-crawlspace.xml,71.59,17.85,7.4,10.49,28.5,4.72,11.78,17.76,5.01,9.44,15.13,0.0,0.0,0.22114,114.95,4964.96,4079.54,1.0587,55.58,1.0,55.58,71.59,71.59,0.0,49.08,1.0,49.08,71.59,71.59,0.0,69.61,19.45,7.34,10.49,31.04,4.7,11.78,17.76,5.01,9.44,15.13,0.0,0.0,0.22114 -base-foundation-vented-crawlspace.xml,73.43,17.85,7.4,10.49,28.5,4.72,11.78,19.77,4.91,9.52,15.13,0.0,0.0,0.22114,121.73,5257.52,4079.54,1.0587,55.58,1.0,55.58,73.43,73.43,0.0,49.08,1.0,49.08,73.43,73.43,0.0,71.4,19.45,7.34,10.49,31.04,4.7,11.78,19.77,4.91,9.52,15.13,0.0,0.0,0.22114 -base-foundation-walkout-basement.xml,81.29,31.1,9.14,10.49,49.54,5.65,11.52,42.1,5.48,9.17,21.28,0.0,0.0,0.22114,160.69,9035.46,5667.47,0.9921,57.07,1.0,57.07,81.29,81.29,0.0,50.13,1.0,50.13,81.29,81.29,0.0,75.05,37.74,9.01,10.49,60.1,5.56,11.53,42.1,5.48,9.17,21.28,0.0,0.0,0.22114 -base-hvac-air-to-air-heat-pump-1-speed-cooling-only.xml,84.81,29.96,8.29,10.49,47.71,4.31,11.52,44.41,4.03,9.17,21.28,0.0,0.0,0.22146,163.53,9255.59,5600.77,1.0105,69.78,1.0,69.78,84.81,84.81,0.0,56.9,1.0,56.9,84.81,84.81,0.0,80.53,34.08,8.18,10.49,54.27,4.27,11.53,44.41,4.03,9.17,21.28,0.0,0.0,0.22146 -base-hvac-air-to-air-heat-pump-1-speed-heating-only.xml,86.03,29.96,8.29,10.49,23.26,5.23,11.52,22.43,4.84,9.17,21.28,0.0,0.0,0.21906,85.11,4886.13,5681.45,1.0104,54.86,1.0,54.86,86.03,86.03,0.0,48.61,1.0,48.61,86.03,86.03,0.0,81.97,34.08,8.18,10.49,26.24,5.19,11.53,22.43,4.84,9.17,21.28,0.0,0.0,0.21906 -base-hvac-air-to-air-heat-pump-1-speed-lockout-temperatures.xml,83.98,29.96,8.3,10.49,22.48,4.42,11.52,20.92,3.79,9.17,21.28,0.0,0.0,0.21969,83.28,4659.98,5537.46,1.0105,51.84,1.0,51.84,83.98,83.98,0.0,45.24,1.0,45.24,83.98,83.98,0.0,80.13,34.08,8.19,10.49,25.3,4.37,11.53,20.92,3.79,9.17,21.28,0.0,0.0,0.21969 -base-hvac-air-to-air-heat-pump-1-speed-seer2-hspf2.xml,83.95,29.96,8.3,10.49,22.48,4.42,11.52,20.92,3.77,9.17,21.28,0.0,0.0,0.21969,83.23,4657.27,5537.46,1.0105,51.84,1.0,51.84,83.95,83.95,0.0,45.24,1.0,45.24,83.95,83.95,0.0,80.1,34.08,8.19,10.49,25.3,4.37,11.53,20.92,3.77,9.17,21.28,0.0,0.0,0.21969 -base-hvac-air-to-air-heat-pump-1-speed.xml,83.73,29.96,8.3,10.49,22.48,4.42,11.52,20.77,3.79,9.17,21.28,0.0,0.0,0.21969,83.01,4644.79,5537.46,1.0105,51.84,1.0,51.84,83.73,83.73,0.0,45.24,1.0,45.24,83.73,83.73,0.0,79.88,34.08,8.19,10.49,25.3,4.37,11.53,20.77,3.79,9.17,21.28,0.0,0.0,0.21969 -base-hvac-air-to-air-heat-pump-2-speed.xml,70.76,29.96,8.3,10.49,22.48,4.42,11.52,14.84,2.68,9.17,21.28,0.0,0.0,0.21969,72.06,4032.24,5537.46,1.0105,51.84,1.0,51.84,70.76,70.76,0.0,45.24,1.0,45.24,70.76,70.76,0.0,67.46,34.08,8.19,10.49,25.3,4.37,11.53,14.84,2.68,9.17,21.28,0.0,0.0,0.21969 -base-hvac-air-to-air-heat-pump-var-speed.xml,69.31,29.96,8.3,10.49,22.48,4.27,11.52,14.25,2.42,9.17,21.28,0.0,0.0,0.2196,70.93,3961.44,5526.97,1.0105,51.9,1.0,51.9,69.31,69.31,0.0,45.33,1.0,45.33,69.31,69.31,0.0,66.07,34.08,8.18,10.49,25.3,4.23,11.53,14.25,2.42,9.17,21.28,0.0,0.0,0.2196 -base-hvac-boiler-elec-only.xml,99.26,29.96,8.29,10.49,23.26,5.23,11.52,30.32,4.84,9.17,21.28,0.0,0.0,0.21906,97.29,5585.18,5681.45,1.0104,54.86,1.0,54.86,99.26,99.26,0.0,48.61,1.0,48.61,99.26,99.26,0.0,94.63,34.08,8.18,10.49,26.24,5.19,11.53,30.32,4.84,9.17,21.28,0.0,0.0,0.21906 -base-hvac-boiler-gas-only.xml,71.66,29.96,8.29,10.49,48.99,5.23,11.52,32.29,4.84,9.17,21.28,0.0,0.0,0.23051,132.18,7592.29,5681.45,1.011,56.84,1.0,56.84,71.66,71.66,0.0,50.2,1.0,50.2,71.66,71.66,0.0,68.08,34.08,8.18,10.49,55.57,5.19,11.53,32.29,4.84,9.17,21.28,0.0,0.0,0.23051 -base-hvac-boiler-oil-only.xml,71.67,29.96,8.29,10.49,48.99,5.23,11.52,32.31,4.84,9.17,21.28,0.0,0.0,0.23051,159.05,9135.65,5681.45,1.011,56.84,1.0,56.84,71.67,71.67,0.0,50.2,1.0,50.2,71.67,71.67,0.0,68.09,34.08,8.18,10.49,55.57,5.19,11.53,32.31,4.84,9.17,21.28,0.0,0.0,0.23051 -base-hvac-boiler-propane-only.xml,71.65,29.96,8.29,10.49,48.99,5.23,11.52,32.29,4.84,9.17,21.28,0.0,0.0,0.23051,149.24,8572.12,5681.45,1.011,56.84,1.0,56.84,71.65,71.65,0.0,50.2,1.0,50.2,71.65,71.65,0.0,68.08,34.08,8.18,10.49,55.57,5.19,11.53,32.29,4.84,9.17,21.28,0.0,0.0,0.23051 -base-hvac-central-ac-only-1-speed-seer2.xml,85.47,29.96,8.29,10.49,47.71,5.23,11.52,44.41,5.21,9.17,21.28,0.0,0.0,0.22161,162.89,9352.3,5681.45,1.0106,71.26,1.0,71.26,85.47,85.47,0.0,58.28,1.0,58.28,85.47,85.47,0.0,81.14,34.08,8.18,10.49,54.27,5.19,11.53,44.41,5.21,9.17,21.28,0.0,0.0,0.22161 -base-hvac-central-ac-only-1-speed.xml,85.51,29.96,8.29,10.49,47.71,5.23,11.52,44.41,5.23,9.17,21.28,0.0,0.0,0.22161,162.91,9353.41,5681.45,1.0106,71.26,1.0,71.26,85.51,85.51,0.0,58.28,1.0,58.28,85.51,85.51,0.0,81.17,34.08,8.18,10.49,54.27,5.19,11.53,44.41,5.23,9.17,21.28,0.0,0.0,0.22161 -base-hvac-central-ac-only-2-speed.xml,83.01,29.96,8.29,10.49,47.71,5.23,11.52,44.41,4.02,9.17,21.28,0.0,0.0,0.22161,161.38,9265.65,5681.45,1.0106,71.26,1.0,71.26,83.01,83.01,0.0,58.28,1.0,58.28,83.01,83.01,0.0,78.82,34.08,8.18,10.49,54.27,5.19,11.53,44.41,4.02,9.17,21.28,0.0,0.0,0.22161 -base-hvac-central-ac-only-var-speed.xml,82.05,29.96,8.29,10.49,47.71,5.09,11.52,44.41,3.45,9.17,21.28,0.0,0.0,0.22159,160.94,9224.46,5671.6,1.0106,71.28,1.0,71.28,82.05,82.05,0.0,58.31,1.0,58.31,82.05,82.05,0.0,77.9,34.08,8.18,10.49,54.27,5.06,11.53,44.41,3.45,9.17,21.28,0.0,0.0,0.22159 -base-hvac-central-ac-plus-air-to-air-heat-pump-heating.xml,86.82,29.96,8.29,10.49,23.26,5.23,11.52,22.43,5.23,9.17,21.28,0.0,0.0,0.21906,85.54,4910.69,5681.45,1.0104,53.71,1.0,53.71,86.82,86.82,0.0,46.95,1.0,46.95,86.82,86.82,0.0,82.71,34.08,8.18,10.49,26.24,5.19,11.53,22.43,5.23,9.17,21.28,0.0,0.0,0.21906 -base-hvac-dse.xml,78.69,29.96,8.29,10.49,47.71,5.17,11.52,37.86,5.54,9.17,21.28,0.0,0.0,0.22114,150.79,8437.6,5537.46,1.0105,56.26,1.0,56.26,78.69,78.69,0.0,48.82,1.0,48.82,78.69,78.69,0.0,74.71,34.08,8.18,10.49,54.27,5.12,11.53,37.86,5.54,9.17,21.28,0.0,0.0,0.22114 -base-hvac-dual-fuel-air-to-air-heat-pump-1-speed-lockout-temperatures.xml,80.86,29.96,8.3,10.49,32.12,4.42,11.52,28.0,3.79,9.17,21.28,0.0,0.0,0.21937,109.25,6112.83,5537.46,1.0104,51.84,1.0,51.84,80.86,80.86,0.0,45.24,1.0,45.24,80.86,80.86,0.0,77.1,34.09,8.19,10.49,35.93,4.37,11.53,28.0,3.79,9.17,21.28,0.0,0.0,0.21937 -base-hvac-dual-fuel-air-to-air-heat-pump-1-speed.xml,80.2,29.96,8.3,10.49,35.76,4.42,11.52,31.07,3.79,9.17,21.28,0.0,0.0,0.21923,119.73,6699.31,5537.46,1.0104,51.84,1.0,51.84,80.2,80.2,0.0,45.24,1.0,45.24,80.2,80.2,0.0,76.44,34.08,8.19,10.49,40.03,4.37,11.53,31.07,3.79,9.17,21.28,0.0,0.0,0.21923 -base-hvac-ducts-buried.xml,75.76,29.96,8.29,10.49,47.71,5.17,11.52,36.33,4.68,9.17,21.28,0.0,0.0,0.22114,145.54,8143.81,5537.46,1.0105,56.29,1.0,56.29,75.76,75.76,0.0,48.86,1.0,48.86,75.76,75.76,0.0,71.94,34.08,8.18,10.49,54.27,5.12,11.53,36.33,4.68,9.17,21.28,0.0,0.0,0.22114 -base-hvac-ducts-leakage-cfm50.xml,77.51,29.96,8.29,10.49,47.71,5.17,11.52,37.94,4.94,9.17,21.28,0.0,0.0,0.22114,149.97,8392.07,5537.46,1.0105,56.29,1.0,56.29,77.51,77.51,0.0,48.86,1.0,48.86,77.51,77.51,0.0,73.6,34.08,8.18,10.49,54.27,5.12,11.53,37.94,4.94,9.17,21.28,0.0,0.0,0.22114 -base-hvac-elec-resistance-only.xml,95.21,29.96,8.29,10.49,23.26,5.23,11.52,27.91,4.84,9.17,21.28,0.0,0.0,0.21906,93.63,5374.98,5681.45,1.0104,54.86,1.0,54.86,95.21,95.21,0.0,48.61,1.0,48.61,95.21,95.21,0.0,90.76,34.08,8.18,10.49,26.24,5.19,11.53,27.91,4.84,9.17,21.28,0.0,0.0,0.21906 -base-hvac-evap-cooler-only-ducted.xml,76.22,29.96,8.29,10.49,47.71,5.23,11.52,44.41,0.71,9.17,21.28,0.0,0.0,0.22161,157.04,9016.39,5681.45,1.0106,71.26,1.0,71.26,76.22,76.22,0.0,58.28,1.0,58.28,76.22,76.22,0.0,72.4,34.08,8.18,10.49,54.27,5.19,11.53,44.41,0.71,9.17,21.28,0.0,0.0,0.22161 -base-hvac-evap-cooler-only.xml,76.06,29.96,8.29,10.49,47.71,5.23,11.52,44.41,0.64,9.17,21.28,0.0,0.0,0.22161,156.95,9010.99,5681.45,1.0106,71.26,1.0,71.26,76.06,76.06,0.0,58.28,1.0,58.28,76.06,76.06,0.0,72.24,34.08,8.18,10.49,54.27,5.19,11.53,44.41,0.64,9.17,21.28,0.0,0.0,0.22161 -base-hvac-fireplace-wood-only.xml,76.65,29.96,8.29,10.49,47.71,5.23,11.52,34.88,4.84,9.17,21.28,0.0,0.0,0.22161,,,,,57.41,1.0,57.41,76.65,76.65,0.0,50.48,1.0,50.48,76.65,76.65,0.0,72.76,34.08,8.18,10.49,54.27,5.19,11.53,34.88,4.84,9.17,21.28,0.0,0.0,0.22161 -base-hvac-fixed-heater-gas-only.xml,68.66,29.96,8.29,10.49,47.71,5.23,11.52,27.91,4.84,9.17,21.28,0.0,0.0,0.22161,121.24,6960.74,5681.45,1.0106,57.41,1.0,57.41,68.66,68.66,0.0,50.48,1.0,50.48,68.66,68.66,0.0,65.17,34.08,8.18,10.49,54.27,5.19,11.53,27.91,4.84,9.17,21.28,0.0,0.0,0.22161 -base-hvac-floor-furnace-propane-only.xml,76.65,29.96,8.29,10.49,47.71,5.23,11.52,34.88,4.84,9.17,21.28,0.0,0.0,0.22161,157.67,9052.38,5681.45,1.0106,57.41,1.0,57.41,76.65,76.65,0.0,50.48,1.0,50.48,76.65,76.65,0.0,72.76,34.08,8.18,10.49,54.27,5.19,11.53,34.88,4.84,9.17,21.28,0.0,0.0,0.22161 -base-hvac-furnace-elec-only.xml,111.65,29.96,8.29,10.49,23.26,5.23,11.52,37.73,4.84,9.17,21.28,0.0,0.0,0.21906,109.05,6260.51,5681.45,1.0104,54.86,1.0,54.86,111.65,111.65,0.0,48.61,1.0,48.61,111.65,111.65,0.0,106.5,34.08,8.18,10.49,26.24,5.19,11.53,37.73,4.84,9.17,21.28,0.0,0.0,0.21906 -base-hvac-furnace-gas-only.xml,78.84,29.96,8.29,10.49,47.71,5.23,11.52,40.11,4.84,9.17,21.28,0.0,0.0,0.22161,151.38,8691.32,5681.45,1.0106,57.41,1.0,57.41,78.84,78.84,0.0,50.48,1.0,50.48,78.84,78.84,0.0,74.84,34.08,8.18,10.49,54.27,5.19,11.53,40.11,4.84,9.17,21.28,0.0,0.0,0.22161 -base-hvac-ground-to-air-heat-pump-cooling-only.xml,82.58,29.96,8.29,10.49,47.71,4.31,11.52,44.41,3.13,9.17,21.28,0.0,0.0,0.22146,162.45,9194.32,5600.77,1.0105,69.78,1.0,69.78,82.58,82.58,0.0,56.9,1.0,56.9,82.58,82.58,0.0,78.42,34.08,8.18,10.49,54.27,4.27,11.53,44.41,3.13,9.17,21.28,0.0,0.0,0.22146 -base-hvac-ground-to-air-heat-pump-heating-only.xml,69.78,29.96,8.29,10.49,23.26,5.23,11.52,12.72,4.84,9.17,21.28,0.0,0.0,0.21906,69.6,3995.45,5681.45,1.0104,54.86,1.0,54.86,69.78,69.78,0.0,48.61,1.0,48.61,69.78,69.78,0.0,66.4,34.08,8.18,10.49,26.24,5.19,11.53,12.72,4.84,9.17,21.28,0.0,0.0,0.21906 -base-hvac-ground-to-air-heat-pump.xml,65.62,29.96,8.3,10.49,22.48,4.42,11.52,11.11,3.22,9.17,21.28,0.0,0.0,0.21969,66.52,3721.93,5537.46,1.0105,51.84,1.0,51.84,65.62,65.62,0.0,45.24,1.0,45.24,65.62,65.62,0.0,62.51,34.08,8.19,10.49,25.3,4.37,11.53,11.11,3.22,9.17,21.28,0.0,0.0,0.21969 -base-hvac-install-quality-air-to-air-heat-pump-1-speed.xml,82.23,29.96,8.3,10.49,22.48,4.42,11.52,20.43,3.41,9.17,21.28,0.0,0.0,0.21969,81.98,4587.26,5537.46,1.0105,51.84,1.0,51.84,82.23,82.23,0.0,45.24,1.0,45.24,82.23,82.23,0.0,78.45,34.08,8.19,10.49,25.3,4.37,11.53,20.43,3.41,9.17,21.28,0.0,0.0,0.21969 -base-hvac-install-quality-furnace-gas-central-ac-1-speed.xml,78.34,29.96,8.29,10.49,47.71,5.17,11.52,39.63,4.72,9.17,21.28,0.0,0.0,0.22114,154.4,8640.01,5537.46,1.0105,56.29,1.0,56.29,78.34,78.34,0.0,48.86,1.0,48.86,78.34,78.34,0.0,74.39,34.08,8.18,10.49,54.27,5.12,11.53,39.63,4.72,9.17,21.28,0.0,0.0,0.22114 -base-hvac-install-quality-ground-to-air-heat-pump.xml,64.16,29.96,8.3,10.49,22.48,4.42,11.52,11.0,2.7,9.17,21.28,0.0,0.0,0.21969,65.67,3674.24,5537.46,1.0105,51.84,1.0,51.84,64.16,64.16,0.0,45.24,1.0,45.24,64.16,64.16,0.0,61.13,34.08,8.19,10.49,25.3,4.37,11.53,11.0,2.7,9.17,21.28,0.0,0.0,0.21969 -base-hvac-install-quality-mini-split-air-conditioner-only-ducted.xml,80.62,29.96,8.29,10.49,47.71,5.23,11.52,44.41,2.85,9.17,21.28,0.0,0.0,0.22161,159.94,9182.9,5681.45,1.0106,71.26,1.0,71.26,80.62,80.62,0.0,58.28,1.0,58.28,80.62,80.62,0.0,76.55,34.08,8.18,10.49,54.27,5.19,11.53,44.41,2.85,9.17,21.28,0.0,0.0,0.22161 -base-hvac-install-quality-mini-split-heat-pump-ducted.xml,64.45,29.96,8.3,10.49,22.48,4.42,11.52,12.11,2.03,9.17,21.28,0.0,0.0,0.21969,66.81,3738.53,5537.46,1.0105,51.84,1.0,51.84,64.45,64.45,0.0,45.24,1.0,45.24,64.45,64.45,0.0,61.42,34.08,8.19,10.49,25.3,4.37,11.53,12.11,2.03,9.17,21.28,0.0,0.0,0.21969 -base-hvac-mini-split-air-conditioner-only-ducted.xml,80.8,29.96,8.29,10.49,47.71,5.23,11.52,44.41,2.94,9.17,21.28,0.0,0.0,0.22161,160.05,9189.22,5681.45,1.0106,71.26,1.0,71.26,80.8,80.8,0.0,58.28,1.0,58.28,80.8,80.8,0.0,76.72,34.08,8.18,10.49,54.27,5.19,11.53,44.41,2.94,9.17,21.28,0.0,0.0,0.22161 -base-hvac-mini-split-air-conditioner-only-ductless.xml,78.98,29.96,8.29,10.49,47.71,5.23,11.52,44.41,2.06,9.17,21.28,0.0,0.0,0.22161,158.95,9125.96,5681.45,1.0106,71.26,1.0,71.26,78.98,78.98,0.0,58.28,1.0,58.28,78.98,78.98,0.0,75.01,34.08,8.18,10.49,54.27,5.19,11.53,44.41,2.06,9.17,21.28,0.0,0.0,0.22161 -base-hvac-mini-split-heat-pump-ducted-cooling-only.xml,79.98,29.96,8.29,10.49,47.71,4.31,11.52,44.41,2.09,9.17,21.28,0.0,0.0,0.22146,161.08,9117.04,5600.77,1.0105,69.78,1.0,69.78,79.98,79.98,0.0,56.9,1.0,56.9,79.98,79.98,0.0,75.95,34.08,8.18,10.49,54.27,4.27,11.53,44.41,2.09,9.17,21.28,0.0,0.0,0.22146 -base-hvac-mini-split-heat-pump-ducted-heating-only.xml,69.4,29.96,8.29,10.49,23.26,5.23,11.52,12.49,4.84,9.17,21.28,0.0,0.0,0.21906,69.49,3989.34,5681.45,1.0104,54.86,1.0,54.86,69.4,69.4,0.0,48.61,1.0,48.61,69.4,69.4,0.0,66.04,34.08,8.18,10.49,26.24,5.19,11.53,12.49,4.84,9.17,21.28,0.0,0.0,0.21906 -base-hvac-mini-split-heat-pump-ducted.xml,65.11,29.96,8.3,10.49,22.48,4.42,11.52,12.4,2.1,9.17,21.28,0.0,0.0,0.21969,67.37,3769.5,5537.46,1.0105,51.84,1.0,51.84,65.11,65.11,0.0,45.24,1.0,45.24,65.11,65.11,0.0,62.06,34.08,8.19,10.49,25.3,4.37,11.53,12.4,2.1,9.17,21.28,0.0,0.0,0.21969 -base-hvac-mini-split-heat-pump-ductless.xml,57.48,29.96,8.3,10.49,22.48,4.42,11.52,8.95,1.42,9.17,21.28,0.0,0.0,0.21969,60.84,3404.26,5537.46,1.0105,51.84,1.0,51.84,57.48,57.48,0.0,45.24,1.0,45.24,57.48,57.48,0.0,54.75,34.08,8.19,10.49,25.3,4.37,11.53,8.95,1.42,9.17,21.28,0.0,0.0,0.21969 -base-hvac-multiple.xml,92.81,30.0,8.31,10.49,35.97,7.13,11.52,42.72,5.1,9.17,21.28,0.0,0.0,0.2121,133.49,8342.29,6187.05,1.0101,54.85,1.0,54.85,92.81,92.81,0.0,49.27,1.0,49.27,92.81,92.81,0.0,89.1,34.1,8.19,10.49,40.27,7.12,11.53,42.72,5.1,9.17,21.28,0.0,0.0,0.2121 +base-dhw-combi-tankless.xml,64.76,29.23,8.57,10.49,47.84,5.37,18.31,32.66,4.78,10.47,21.28,0.0,0.0,0.22999,147.08,8447.62,5681.45,1.011,54.88,1.0,54.88,64.76,64.76,0.0,49.18,1.0,49.18,64.76,64.76,0.0,61.54,33.33,8.45,10.49,54.39,5.32,18.32,32.66,4.78,10.47,21.28,0.0,0.0,0.22999 +base-dhw-desuperheater.xml,83.81,29.96,8.29,10.49,47.71,5.23,11.52,44.9,5.44,7.04,21.28,0.0,0.0,0.22161,161.47,9270.88,5681.45,1.0106,71.26,1.0,71.26,83.81,83.81,0.0,59.72,1.0,59.72,83.81,83.81,0.0,79.56,34.08,8.18,10.49,54.27,5.19,11.53,44.9,5.44,7.04,21.28,0.0,0.0,0.22161 +base-dhw-dwhr.xml,76.58,29.96,8.29,10.49,47.71,5.17,11.52,39.56,5.17,6.93,21.28,0.0,0.0,0.22114,151.23,8462.37,5537.46,1.0105,56.29,1.0,56.29,76.58,76.58,0.0,49.72,1.0,49.72,76.58,76.58,0.0,72.71,34.08,8.18,10.49,54.27,5.12,11.53,39.56,5.17,6.93,21.28,0.0,0.0,0.22114 +base-dhw-indirect-standbyloss.xml,68.67,29.14,8.6,10.49,47.71,5.39,18.65,30.97,5.08,14.25,21.28,0.0,0.0,0.22505,152.43,8778.1,5697.86,1.0107,54.88,1.0,54.88,68.67,68.67,0.0,49.18,1.0,49.18,68.67,68.67,0.0,65.24,33.24,8.48,10.49,54.25,5.34,18.66,30.97,5.08,14.25,21.28,0.0,0.0,0.22505 +base-dhw-jacket-gas.xml,79.34,29.14,8.6,10.49,46.41,5.33,18.65,38.69,5.3,14.42,21.28,0.0,0.0,0.21601,176.65,9912.5,5554.21,1.0103,53.97,1.0,53.97,79.34,79.34,0.0,47.41,1.0,47.41,79.34,79.34,0.0,75.34,33.24,8.48,10.49,52.94,5.27,18.66,38.69,5.3,14.42,21.28,0.0,0.0,0.21601 +base-dhw-jacket-hpwh.xml,75.21,29.48,8.47,10.49,46.94,5.26,12.42,44.49,4.56,3.42,21.28,0.0,0.0,0.21121,156.75,8853.21,5591.67,1.0101,56.59,1.0,56.59,75.21,75.21,0.0,50.01,1.0,50.01,75.21,75.21,0.0,71.42,33.58,8.36,10.49,53.48,5.21,12.42,44.49,4.56,3.42,21.28,0.0,0.0,0.21121 +base-dhw-jacket-indirect.xml,67.56,29.14,8.6,10.49,47.71,5.39,18.65,31.46,4.99,13.28,21.28,0.0,0.0,0.22505,151.08,8700.71,5697.86,1.0107,54.88,1.0,54.88,67.56,67.56,0.0,49.18,1.0,49.18,67.56,67.56,0.0,64.19,33.24,8.48,10.49,54.25,5.34,18.66,31.46,4.99,13.28,21.28,0.0,0.0,0.22505 +base-dhw-low-flow-fixtures.xml,78.79,29.96,8.29,10.49,47.71,5.17,11.52,39.56,5.17,8.8,21.28,0.0,0.0,0.22114,153.91,8612.38,5537.46,1.0105,56.29,1.0,56.29,78.79,78.79,0.0,49.72,1.0,49.72,78.79,78.79,0.0,74.81,34.08,8.18,10.49,54.27,5.12,11.53,39.56,5.17,8.8,21.28,0.0,0.0,0.22114 +base-dhw-multiple.xml,67.77,29.96,8.29,10.5,48.99,5.23,11.5,31.66,4.96,6.0600000000000005,21.28,0.0,0.0,0.23051,131.15,7533.13,5681.6,1.011,61.27,1.0,61.27,67.77,67.77,0.0,55.34,1.0,55.34,67.77,67.77,0.0,64.39,34.08,8.18,10.5,55.57,5.19,11.54,31.66,4.96,6.0600000000000005,21.28,0.0,0.0,0.23051 +base-dhw-none.xml,83.4,29.23,8.57,10.49,46.55,5.31,18.31,38.16,5.38,18.3,22.38,0.0,0.0,0.22089,187.63,10499.27,5537.46,1.0105,61.22,1.0,61.22,83.4,83.4,0.0,55.53,1.0,55.53,83.4,83.4,0.0,79.19,33.33,8.45,10.49,53.07,5.25,18.32,38.16,5.38,18.3,22.38,0.0,0.0,0.22089 +base-dhw-recirc-demand.xml,79.17,29.96,8.29,10.49,47.71,5.17,11.52,39.56,5.17,9.12,21.28,0.0,0.0,0.22114,154.36,8637.75,5537.46,1.0105,56.29,1.0,56.29,79.17,79.17,0.0,49.72,1.0,49.72,79.17,79.17,0.0,75.17,34.08,8.18,10.49,54.27,5.12,11.53,39.56,5.17,9.12,21.28,0.0,0.0,0.22114 +base-dhw-solar-fraction.xml,72.31,29.96,8.29,10.49,47.71,5.17,11.52,39.86,5.13,3.21,21.28,0.0,0.0,0.22114,146.6,8203.51,5537.46,1.0105,56.29,1.0,56.29,72.31,72.31,0.0,49.72,1.0,49.72,72.31,72.31,0.0,68.65,34.08,8.18,10.49,54.27,5.12,11.53,39.86,5.13,3.21,21.28,0.0,0.0,0.22114 +base-dhw-solar-indirect-flat-plate.xml,70.53,29.96,8.29,10.49,47.71,5.17,11.52,39.15,5.34,1.8,21.28,0.0,0.0,0.22114,143.1,8007.73,5537.46,1.0105,56.29,1.0,56.29,70.53,70.53,0.0,49.72,1.0,49.72,70.53,70.53,0.0,66.96,34.08,8.18,10.49,54.27,5.12,11.53,39.15,5.34,1.8,21.28,0.0,0.0,0.22114 +base-dhw-tank-elec-uef.xml,79.24,30.03,8.26,10.49,47.83,5.16,11.39,39.5,5.18,9.24,21.28,0.0,0.0,0.22269,154.63,8640.3,5528.96,1.0106,56.51,1.0,56.51,79.24,79.24,0.0,49.92,1.0,49.92,79.24,79.24,0.0,75.24,34.16,8.15,10.49,54.4,5.11,11.39,39.5,5.18,9.24,21.28,0.0,0.0,0.22269 +base-dhw-tank-gas-uef.xml,79.48,29.38,8.51,10.49,46.8,5.28,17.66,38.56,5.32,14.94,21.28,0.0,0.0,0.23022,178.38,9970.67,5528.96,1.011,53.97,1.0,53.97,79.48,79.48,0.0,47.41,1.0,47.41,79.48,79.48,0.0,75.47,33.49,8.39,10.49,53.33,5.22,17.67,38.56,5.32,14.94,21.28,0.0,0.0,0.23022 +base-dhw-tank-heat-pump-uef.xml,74.26,29.8,8.35,10.49,47.46,5.2,11.81,45.4,4.44,2.43,21.28,0.0,0.0,0.21797,158.62,8901.69,5554.21,1.0104,56.31,1.0,56.31,74.26,74.26,0.0,49.79,1.0,49.79,74.26,74.26,0.0,70.51,33.92,8.23,10.49,54.02,5.15,11.81,45.4,4.44,2.43,21.28,0.0,0.0,0.21797 +base-dhw-tank-oil.xml,79.96,29.14,8.6,10.49,46.41,5.33,18.65,38.25,5.36,15.51,21.28,0.0,0.0,0.21601,191.9,10767.88,5554.21,1.0103,53.97,1.0,53.97,79.96,79.96,0.0,47.41,1.0,47.41,79.96,79.96,0.0,75.92,33.24,8.48,10.49,52.94,5.27,18.66,38.25,5.36,15.51,21.28,0.0,0.0,0.21601 +base-dhw-tank-wood.xml,79.96,29.14,8.6,10.49,46.41,5.33,18.65,38.25,5.36,15.51,21.28,0.0,0.0,0.21601,,,,,53.97,1.0,53.97,79.96,79.96,0.0,47.41,1.0,47.41,79.96,79.96,0.0,75.92,33.24,8.48,10.49,52.94,5.27,18.66,38.25,5.36,15.51,21.28,0.0,0.0,0.21601 +base-dhw-tankless-electric-uef.xml,79.62,29.96,8.29,10.49,47.71,5.17,11.52,40.02,5.11,9.33,21.28,0.0,0.0,0.22114,155.73,8714.44,5537.46,1.0105,56.43,1.0,56.43,79.62,79.62,0.0,49.84,1.0,49.84,79.62,79.62,0.0,75.6,34.08,8.18,10.49,54.27,5.12,11.53,40.02,5.11,9.33,21.28,0.0,0.0,0.22114 +base-dhw-tankless-gas-uef.xml,72.84,29.23,8.57,10.49,46.55,5.31,18.31,40.02,5.11,9.83,21.28,0.0,0.0,0.22089,168.27,9415.62,5537.46,1.0105,53.97,1.0,53.97,72.84,72.84,0.0,47.41,1.0,47.41,72.84,72.84,0.0,69.16,33.33,8.45,10.49,53.07,5.25,18.32,40.02,5.11,9.83,21.28,0.0,0.0,0.22089 +base-dhw-tankless-propane.xml,75.2,29.23,8.57,10.49,46.55,5.31,18.31,40.02,5.11,11.39,21.28,0.0,0.0,0.22089,178.58,9992.95,5537.46,1.0105,53.97,1.0,53.97,75.2,75.2,0.0,47.41,1.0,47.41,75.2,75.2,0.0,71.4,33.33,8.45,10.49,53.07,5.25,18.32,40.02,5.11,11.39,21.28,0.0,0.0,0.22089 +base-enclosure-2stories-garage.xml,77.5,39.42,10.45,10.49,62.79,6.17,11.52,42.98,7.17,9.13,23.92,0.0,0.0,0.22114,147.3,9509.26,6588.8,0.9798,56.08,1.0,56.08,77.5,77.5,0.0,50.21,1.0,50.21,77.5,77.5,0.0,70.92,48.01,10.33,10.49,76.46,6.1,11.53,42.98,7.17,9.13,23.92,0.0,0.0,0.22114 +base-enclosure-2stories.xml,77.46,46.06,12.1,10.49,73.37,7.03,11.53,52.05,6.94,9.01,27.42,0.0,0.0,0.22114,153.66,11091.72,7476.66,0.9654,55.74,1.0,55.74,77.46,77.46,0.0,49.74,1.0,49.74,77.46,77.46,0.0,71.03,55.72,11.97,10.49,88.75,6.91,11.53,52.05,6.94,9.01,27.42,0.0,0.0,0.22114 +base-enclosure-beds-1.xml,83.92,29.61,7.66,6.16,47.15,4.78,7.19,41.78,4.82,5.56,19.85,0.0,0.0,0.22136,174.69,8534.08,4986.52,0.9797,57.84,1.0,57.84,83.92,83.92,0.0,51.71,1.0,51.71,83.92,83.92,0.0,79.24,33.73,7.56,6.16,53.72,4.74,7.19,41.78,4.82,5.56,19.85,0.0,0.0,0.22136 +base-enclosure-beds-2.xml,81.42,29.78,7.97,8.39,47.43,5.0,9.42,40.68,5.0,7.4,20.56,0.0,0.0,0.22124,164.09,8592.24,5262.04,0.9951,57.02,1.0,57.02,81.42,81.42,0.0,50.66,1.0,50.66,81.42,81.42,0.0,77.22,33.91,7.87,8.39,54.0,4.9,9.42,40.68,5.0,7.4,20.56,0.0,0.0,0.22124 +base-enclosure-beds-4.xml,77.05,30.14,8.6,12.54,47.99,5.4,13.57,38.41,5.34,10.9,21.99,0.0,0.0,0.22104,145.87,8684.2,5802.75,1.0259,55.45,1.0,55.45,77.05,77.05,0.0,48.72,1.0,48.72,77.05,77.05,0.0,73.44,34.25,8.49,12.54,54.55,5.29,13.57,38.41,5.34,10.9,21.99,0.0,0.0,0.22104 +base-enclosure-beds-5.xml,75.18,30.32,8.93,14.54,48.29,5.55,15.57,37.27,5.51,12.6,22.7,0.0,0.0,0.22096,138.16,8725.71,6064.75,1.0413,54.69,1.0,54.69,75.18,75.18,0.0,47.85,1.0,47.85,75.18,75.18,0.0,71.67,34.43,8.8,14.54,54.83,5.51,15.57,37.27,5.51,12.6,22.7,0.0,0.0,0.22096 +base-enclosure-garage.xml,77.66,29.93,6.76,10.49,47.68,4.45,11.73,41.31,3.32,9.26,21.42,0.0,0.0,0.22114,157.57,8790.53,5520.75,1.0105,56.92,1.0,56.92,77.66,77.66,0.0,50.27,1.0,50.27,77.66,77.66,0.0,73.58,34.1,6.68,10.49,54.31,4.44,11.73,41.31,3.32,9.26,21.42,0.0,0.0,0.22114 +base-enclosure-infil-ach-house-pressure.xml,79.23,29.96,8.29,10.49,47.71,5.17,11.52,39.56,5.17,9.17,21.28,0.0,0.0,0.22114,154.43,8641.78,5537.46,1.0105,56.29,1.0,56.29,79.23,79.23,0.0,49.72,1.0,49.72,79.23,79.23,0.0,75.23,34.08,8.18,10.49,54.27,5.12,11.53,39.56,5.17,9.17,21.28,0.0,0.0,0.22114 +base-enclosure-infil-cfm-house-pressure.xml,79.23,29.96,8.29,10.49,47.71,5.17,11.52,39.56,5.17,9.17,21.28,0.0,0.0,0.22114,154.43,8641.78,5537.46,1.0105,56.29,1.0,56.29,79.23,79.23,0.0,49.72,1.0,49.72,79.23,79.23,0.0,75.23,34.08,8.18,10.49,54.27,5.12,11.53,39.56,5.17,9.17,21.28,0.0,0.0,0.22114 +base-enclosure-infil-cfm50.xml,79.23,29.96,8.29,10.49,47.71,5.17,11.52,39.56,5.17,9.17,21.28,0.0,0.0,0.22114,154.43,8641.78,5537.46,1.0105,56.29,1.0,56.29,79.23,79.23,0.0,49.72,1.0,49.72,79.23,79.23,0.0,75.23,34.08,8.18,10.49,54.27,5.12,11.53,39.56,5.17,9.17,21.28,0.0,0.0,0.22114 +base-enclosure-infil-ela.xml,79.23,29.96,8.29,10.49,47.71,5.17,11.52,39.56,5.17,9.17,21.28,0.0,0.0,0.22114,154.43,8641.78,5537.46,1.0105,56.29,1.0,56.29,79.23,79.23,0.0,49.72,1.0,49.72,79.23,79.23,0.0,75.23,34.08,8.18,10.49,54.27,5.12,11.53,39.56,5.17,9.17,21.28,0.0,0.0,0.22114 +base-enclosure-infil-natural-ach.xml,79.23,29.96,8.29,10.49,47.71,5.17,11.52,39.56,5.17,9.17,21.28,0.0,0.0,0.22114,154.43,8641.78,5537.46,1.0105,56.29,1.0,56.29,79.23,79.23,0.0,49.72,1.0,49.72,79.23,79.23,0.0,75.23,34.08,8.18,10.49,54.27,5.12,11.53,39.56,5.17,9.17,21.28,0.0,0.0,0.22114 +base-enclosure-infil-natural-cfm.xml,79.23,29.96,8.29,10.49,47.71,5.17,11.52,39.56,5.17,9.17,21.28,0.0,0.0,0.22114,154.43,8641.78,5537.46,1.0105,56.29,1.0,56.29,79.23,79.23,0.0,49.72,1.0,49.72,79.23,79.23,0.0,75.23,34.08,8.18,10.49,54.27,5.12,11.53,39.56,5.17,9.17,21.28,0.0,0.0,0.22114 +base-enclosure-overhangs.xml,79.25,29.96,8.29,10.49,47.71,5.17,11.52,40.07,5.0,9.17,21.28,0.0,0.0,0.22114,155.54,8703.66,5537.46,1.0105,56.29,1.0,56.29,79.25,79.25,0.0,49.72,1.0,49.72,79.25,79.25,0.0,75.25,34.08,8.18,10.49,54.27,5.12,11.53,40.07,5.0,9.17,21.28,0.0,0.0,0.22114 +base-enclosure-skylights.xml,79.71,29.96,8.29,10.49,47.71,5.17,11.52,37.9,5.98,9.17,21.28,0.0,0.0,0.20156,151.46,8467.67,5537.46,1.0096,56.29,1.0,56.29,79.71,79.71,0.0,49.72,1.0,49.72,79.71,79.71,0.0,75.68,34.08,8.18,10.49,54.27,5.12,11.53,37.9,5.98,9.17,21.28,0.0,0.0,0.20156 +base-foundation-ambient.xml,80.36,19.39,7.08,10.49,30.93,4.56,11.52,25.89,5.89,9.36,15.13,0.0,0.0,0.22114,141.52,6210.31,4144.84,1.0587,54.86,1.0,54.86,80.36,80.36,0.0,48.67,1.0,48.67,80.36,80.36,0.0,78.16,20.99,7.03,10.49,33.5,4.53,11.52,25.89,5.89,9.36,15.13,0.0,0.0,0.22114 +base-foundation-basement-garage.xml,76.72,26.96,7.08,10.49,42.93,4.57,11.53,32.65,5.29,9.41,17.78,0.0,0.0,0.22114,145.37,7378.17,4905.14,1.0347,55.16,1.0,55.16,76.72,76.72,0.0,49.11,1.0,49.11,76.72,76.72,0.0,73.7,29.88,7.0,10.49,47.59,4.48,11.53,32.65,5.29,9.41,17.78,0.0,0.0,0.22114 +base-foundation-conditioned-basement-slab-insulation.xml,78.72,29.96,8.29,10.49,47.71,5.17,11.52,38.23,5.42,9.17,21.28,0.0,0.0,0.22114,151.31,8466.7,5537.46,1.0105,56.29,1.0,56.29,78.72,78.72,0.0,49.72,1.0,49.72,78.72,78.72,0.0,74.75,34.08,8.18,10.49,54.27,5.12,11.53,38.23,5.42,9.17,21.28,0.0,0.0,0.22114 +base-foundation-conditioned-basement-wall-insulation.xml,79.31,28.53,7.91,10.49,45.44,4.99,11.52,38.61,4.71,9.17,21.28,0.0,0.0,0.22114,154.17,8468.18,5435.65,1.0105,57.22,1.0,57.22,79.31,79.31,0.0,50.46,1.0,50.46,79.31,79.31,0.0,75.22,32.65,7.81,10.49,51.99,4.94,11.53,38.61,4.71,9.17,21.28,0.0,0.0,0.22114 +base-foundation-multiple.xml,73.41,19.36,6.44,10.49,30.9,4.25,11.67,20.77,5.04,9.32,15.13,0.0,0.0,0.22114,123.57,5396.3,4124.85,1.0587,54.37,1.0,54.37,73.41,73.41,0.0,48.3,1.0,48.3,73.41,73.41,0.0,71.34,20.98,6.4,10.49,33.49,4.24,11.67,20.77,5.04,9.32,15.13,0.0,0.0,0.22114 +base-foundation-slab.xml,66.06,21.07,6.59,10.49,33.56,4.32,11.52,16.69,4.46,9.36,15.13,0.0,0.0,0.22114,107.34,4764.04,4191.91,1.0587,53.93,1.0,53.93,66.06,66.06,0.0,47.87,1.0,47.87,66.06,66.06,0.0,64.27,22.69,6.53,10.49,36.15,4.29,11.53,16.69,4.46,9.36,15.13,0.0,0.0,0.22114 +base-foundation-unconditioned-basement-assembly-r.xml,70.86,19.28,6.6,10.49,30.77,4.34,11.67,19.5,4.53,9.34,15.13,0.0,0.0,0.22114,118.57,5176.83,4123.9,1.0587,53.79,1.0,53.79,70.86,70.86,0.0,47.82,1.0,47.82,70.86,70.86,0.0,68.87,20.91,6.56,10.49,33.37,4.32,11.67,19.5,4.53,9.34,15.13,0.0,0.0,0.22114 +base-foundation-unconditioned-basement-wall-insulation.xml,77.87,19.28,6.6,10.49,30.77,4.34,11.67,27.51,4.23,9.28,15.13,0.0,0.0,0.22114,144.8,6322.31,4123.9,1.0587,53.79,1.0,53.79,77.87,77.87,0.0,47.82,1.0,47.82,77.87,77.87,0.0,75.69,20.91,6.56,10.49,33.37,4.32,11.67,27.51,4.23,9.28,15.13,0.0,0.0,0.22114 +base-foundation-unconditioned-basement.xml,73.66,19.28,6.6,10.49,30.77,4.34,11.67,20.97,5.06,9.34,15.13,0.0,0.0,0.22114,124.33,5428.59,4123.9,1.0587,53.79,1.0,53.79,73.66,73.66,0.0,47.82,1.0,47.82,73.66,73.66,0.0,71.6,20.91,6.56,10.49,33.37,4.32,11.67,20.97,5.06,9.34,15.13,0.0,0.0,0.22114 +base-foundation-unvented-crawlspace.xml,71.59,17.85,7.4,10.49,28.5,4.72,11.78,17.76,5.01,9.44,15.13,0.0,0.0,0.22114,114.95,4964.96,4079.54,1.0587,55.58,1.0,55.58,71.59,71.59,0.0,49.76,1.0,49.76,71.59,71.59,0.0,69.61,19.45,7.34,10.49,31.04,4.7,11.78,17.76,5.01,9.44,15.13,0.0,0.0,0.22114 +base-foundation-vented-crawlspace.xml,73.43,17.85,7.4,10.49,28.5,4.72,11.78,19.77,4.91,9.52,15.13,0.0,0.0,0.22114,121.73,5257.52,4079.54,1.0587,55.58,1.0,55.58,73.43,73.43,0.0,49.76,1.0,49.76,73.43,73.43,0.0,71.4,19.45,7.34,10.49,31.04,4.7,11.78,19.77,4.91,9.52,15.13,0.0,0.0,0.22114 +base-foundation-walkout-basement.xml,81.29,31.1,9.14,10.49,49.54,5.65,11.52,42.1,5.48,9.17,21.28,0.0,0.0,0.22114,160.69,9035.46,5667.47,0.9921,57.07,1.0,57.07,81.29,81.29,0.0,50.94,1.0,50.94,81.29,81.29,0.0,75.05,37.74,9.01,10.49,60.1,5.56,11.53,42.1,5.48,9.17,21.28,0.0,0.0,0.22114 +base-hvac-air-to-air-heat-pump-1-speed-cooling-only.xml,84.81,29.96,8.29,10.49,47.71,4.31,11.52,44.41,4.03,9.17,21.28,0.0,0.0,0.22146,163.53,9255.59,5600.77,1.0105,69.78,1.0,69.78,84.81,84.81,0.0,58.33,1.0,58.33,84.81,84.81,0.0,80.53,34.08,8.18,10.49,54.27,4.27,11.53,44.41,4.03,9.17,21.28,0.0,0.0,0.22146 +base-hvac-air-to-air-heat-pump-1-speed-heating-only.xml,86.03,29.96,8.29,10.49,23.26,5.23,11.52,22.43,4.84,9.17,21.28,0.0,0.0,0.21906,85.11,4886.13,5681.45,1.0104,54.86,1.0,54.86,86.03,86.03,0.0,49.26,1.0,49.26,86.03,86.03,0.0,81.97,34.08,8.18,10.49,26.24,5.19,11.53,22.43,4.84,9.17,21.28,0.0,0.0,0.21906 +base-hvac-air-to-air-heat-pump-1-speed-lockout-temperatures.xml,83.98,29.96,8.3,10.49,22.48,4.42,11.52,20.92,3.79,9.17,21.28,0.0,0.0,0.21969,83.28,4659.98,5537.46,1.0105,51.84,1.0,51.84,83.98,83.98,0.0,45.87,1.0,45.87,83.98,83.98,0.0,80.13,34.08,8.19,10.49,25.3,4.37,11.53,20.92,3.79,9.17,21.28,0.0,0.0,0.21969 +base-hvac-air-to-air-heat-pump-1-speed-seer2-hspf2.xml,83.95,29.96,8.3,10.49,22.48,4.42,11.52,20.92,3.77,9.17,21.28,0.0,0.0,0.21969,83.23,4657.27,5537.46,1.0105,51.84,1.0,51.84,83.95,83.95,0.0,45.87,1.0,45.87,83.95,83.95,0.0,80.1,34.08,8.19,10.49,25.3,4.37,11.53,20.92,3.77,9.17,21.28,0.0,0.0,0.21969 +base-hvac-air-to-air-heat-pump-1-speed.xml,83.73,29.96,8.3,10.49,22.48,4.42,11.52,20.77,3.79,9.17,21.28,0.0,0.0,0.21969,83.01,4644.79,5537.46,1.0105,51.84,1.0,51.84,83.73,83.73,0.0,45.87,1.0,45.87,83.73,83.73,0.0,79.88,34.08,8.19,10.49,25.3,4.37,11.53,20.77,3.79,9.17,21.28,0.0,0.0,0.21969 +base-hvac-air-to-air-heat-pump-2-speed.xml,70.76,29.96,8.3,10.49,22.48,4.42,11.52,14.84,2.68,9.17,21.28,0.0,0.0,0.21969,72.06,4032.24,5537.46,1.0105,51.84,1.0,51.84,70.76,70.76,0.0,45.87,1.0,45.87,70.76,70.76,0.0,67.46,34.08,8.19,10.49,25.3,4.37,11.53,14.84,2.68,9.17,21.28,0.0,0.0,0.21969 +base-hvac-air-to-air-heat-pump-var-speed.xml,69.31,29.96,8.3,10.49,22.48,4.27,11.52,14.25,2.42,9.17,21.28,0.0,0.0,0.2196,70.93,3961.44,5526.97,1.0105,51.9,1.0,51.9,69.31,69.31,0.0,45.96,1.0,45.96,69.31,69.31,0.0,66.07,34.08,8.18,10.49,25.3,4.23,11.53,14.25,2.42,9.17,21.28,0.0,0.0,0.2196 +base-hvac-boiler-elec-only.xml,99.26,29.96,8.29,10.49,23.26,5.23,11.52,30.32,4.84,9.17,21.28,0.0,0.0,0.21906,97.29,5585.18,5681.45,1.0104,54.86,1.0,54.86,99.26,99.26,0.0,49.26,1.0,49.26,99.26,99.26,0.0,94.63,34.08,8.18,10.49,26.24,5.19,11.53,30.32,4.84,9.17,21.28,0.0,0.0,0.21906 +base-hvac-boiler-gas-only.xml,71.66,29.96,8.29,10.49,48.99,5.23,11.52,32.29,4.84,9.17,21.28,0.0,0.0,0.23051,132.18,7592.29,5681.45,1.011,56.84,1.0,56.84,71.66,71.66,0.0,51.02,1.0,51.02,71.66,71.66,0.0,68.08,34.08,8.18,10.49,55.57,5.19,11.53,32.29,4.84,9.17,21.28,0.0,0.0,0.23051 +base-hvac-boiler-oil-only.xml,71.67,29.96,8.29,10.49,48.99,5.23,11.52,32.31,4.84,9.17,21.28,0.0,0.0,0.23051,159.05,9135.65,5681.45,1.011,56.84,1.0,56.84,71.67,71.67,0.0,51.02,1.0,51.02,71.67,71.67,0.0,68.09,34.08,8.18,10.49,55.57,5.19,11.53,32.31,4.84,9.17,21.28,0.0,0.0,0.23051 +base-hvac-boiler-propane-only.xml,71.65,29.96,8.29,10.49,48.99,5.23,11.52,32.29,4.84,9.17,21.28,0.0,0.0,0.23051,149.24,8572.12,5681.45,1.011,56.84,1.0,56.84,71.65,71.65,0.0,51.02,1.0,51.02,71.65,71.65,0.0,68.08,34.08,8.18,10.49,55.57,5.19,11.53,32.29,4.84,9.17,21.28,0.0,0.0,0.23051 +base-hvac-central-ac-only-1-speed-seer2.xml,85.47,29.96,8.29,10.49,47.71,5.23,11.52,44.41,5.21,9.17,21.28,0.0,0.0,0.22161,162.89,9352.3,5681.45,1.0106,71.26,1.0,71.26,85.47,85.47,0.0,59.72,1.0,59.72,85.47,85.47,0.0,81.14,34.08,8.18,10.49,54.27,5.19,11.53,44.41,5.21,9.17,21.28,0.0,0.0,0.22161 +base-hvac-central-ac-only-1-speed.xml,85.51,29.96,8.29,10.49,47.71,5.23,11.52,44.41,5.23,9.17,21.28,0.0,0.0,0.22161,162.91,9353.41,5681.45,1.0106,71.26,1.0,71.26,85.51,85.51,0.0,59.72,1.0,59.72,85.51,85.51,0.0,81.17,34.08,8.18,10.49,54.27,5.19,11.53,44.41,5.23,9.17,21.28,0.0,0.0,0.22161 +base-hvac-central-ac-only-2-speed.xml,83.01,29.96,8.29,10.49,47.71,5.23,11.52,44.41,4.02,9.17,21.28,0.0,0.0,0.22161,161.38,9265.65,5681.45,1.0106,71.26,1.0,71.26,83.01,83.01,0.0,59.72,1.0,59.72,83.01,83.01,0.0,78.82,34.08,8.18,10.49,54.27,5.19,11.53,44.41,4.02,9.17,21.28,0.0,0.0,0.22161 +base-hvac-central-ac-only-var-speed.xml,82.05,29.96,8.29,10.49,47.71,5.09,11.52,44.41,3.45,9.17,21.28,0.0,0.0,0.22159,160.94,9224.46,5671.6,1.0106,71.28,1.0,71.28,82.05,82.05,0.0,59.74,1.0,59.74,82.05,82.05,0.0,77.9,34.08,8.18,10.49,54.27,5.06,11.53,44.41,3.45,9.17,21.28,0.0,0.0,0.22159 +base-hvac-central-ac-plus-air-to-air-heat-pump-heating.xml,86.82,29.96,8.29,10.49,23.26,5.23,11.52,22.43,5.23,9.17,21.28,0.0,0.0,0.21906,85.54,4910.69,5681.45,1.0104,53.71,1.0,53.71,86.82,86.82,0.0,47.62,1.0,47.62,86.82,86.82,0.0,82.71,34.08,8.18,10.49,26.24,5.19,11.53,22.43,5.23,9.17,21.28,0.0,0.0,0.21906 +base-hvac-dse.xml,78.69,29.96,8.29,10.49,47.71,5.17,11.52,37.86,5.54,9.17,21.28,0.0,0.0,0.22114,150.79,8437.6,5537.46,1.0105,56.26,1.0,56.26,78.69,78.69,0.0,49.68,1.0,49.68,78.69,78.69,0.0,74.71,34.08,8.18,10.49,54.27,5.12,11.53,37.86,5.54,9.17,21.28,0.0,0.0,0.22114 +base-hvac-dual-fuel-air-to-air-heat-pump-1-speed-lockout-temperatures.xml,80.86,29.96,8.3,10.49,32.12,4.42,11.52,28.0,3.79,9.17,21.28,0.0,0.0,0.21937,109.25,6112.83,5537.46,1.0104,51.84,1.0,51.84,80.86,80.86,0.0,45.87,1.0,45.87,80.86,80.86,0.0,77.1,34.09,8.19,10.49,35.93,4.37,11.53,28.0,3.79,9.17,21.28,0.0,0.0,0.21937 +base-hvac-dual-fuel-air-to-air-heat-pump-1-speed.xml,80.2,29.96,8.3,10.49,35.76,4.42,11.52,31.07,3.79,9.17,21.28,0.0,0.0,0.21923,119.73,6699.31,5537.46,1.0104,51.84,1.0,51.84,80.2,80.2,0.0,45.87,1.0,45.87,80.2,80.2,0.0,76.44,34.08,8.19,10.49,40.03,4.37,11.53,31.07,3.79,9.17,21.28,0.0,0.0,0.21923 +base-hvac-ducts-buried.xml,75.76,29.96,8.29,10.49,47.71,5.17,11.52,36.33,4.68,9.17,21.28,0.0,0.0,0.22114,145.54,8143.81,5537.46,1.0105,56.29,1.0,56.29,75.76,75.76,0.0,49.72,1.0,49.72,75.76,75.76,0.0,71.94,34.08,8.18,10.49,54.27,5.12,11.53,36.33,4.68,9.17,21.28,0.0,0.0,0.22114 +base-hvac-ducts-leakage-cfm50.xml,77.51,29.96,8.29,10.49,47.71,5.17,11.52,37.94,4.94,9.17,21.28,0.0,0.0,0.22114,149.97,8392.07,5537.46,1.0105,56.29,1.0,56.29,77.51,77.51,0.0,49.72,1.0,49.72,77.51,77.51,0.0,73.6,34.08,8.18,10.49,54.27,5.12,11.53,37.94,4.94,9.17,21.28,0.0,0.0,0.22114 +base-hvac-elec-resistance-only.xml,95.21,29.96,8.29,10.49,23.26,5.23,11.52,27.91,4.84,9.17,21.28,0.0,0.0,0.21906,93.63,5374.98,5681.45,1.0104,54.86,1.0,54.86,95.21,95.21,0.0,49.26,1.0,49.26,95.21,95.21,0.0,90.76,34.08,8.18,10.49,26.24,5.19,11.53,27.91,4.84,9.17,21.28,0.0,0.0,0.21906 +base-hvac-evap-cooler-only-ducted.xml,76.22,29.96,8.29,10.49,47.71,5.23,11.52,44.41,0.71,9.17,21.28,0.0,0.0,0.22161,157.04,9016.39,5681.45,1.0106,71.26,1.0,71.26,76.22,76.22,0.0,59.72,1.0,59.72,76.22,76.22,0.0,72.4,34.08,8.18,10.49,54.27,5.19,11.53,44.41,0.71,9.17,21.28,0.0,0.0,0.22161 +base-hvac-evap-cooler-only.xml,76.06,29.96,8.29,10.49,47.71,5.23,11.52,44.41,0.64,9.17,21.28,0.0,0.0,0.22161,156.95,9010.99,5681.45,1.0106,71.26,1.0,71.26,76.06,76.06,0.0,59.72,1.0,59.72,76.06,76.06,0.0,72.24,34.08,8.18,10.49,54.27,5.19,11.53,44.41,0.64,9.17,21.28,0.0,0.0,0.22161 +base-hvac-fireplace-wood-only.xml,76.65,29.96,8.29,10.49,47.71,5.23,11.52,34.88,4.84,9.17,21.28,0.0,0.0,0.22161,,,,,57.41,1.0,57.41,76.65,76.65,0.0,51.32,1.0,51.32,76.65,76.65,0.0,72.76,34.08,8.18,10.49,54.27,5.19,11.53,34.88,4.84,9.17,21.28,0.0,0.0,0.22161 +base-hvac-fixed-heater-gas-only.xml,68.66,29.96,8.29,10.49,47.71,5.23,11.52,27.91,4.84,9.17,21.28,0.0,0.0,0.22161,121.24,6960.74,5681.45,1.0106,57.41,1.0,57.41,68.66,68.66,0.0,51.32,1.0,51.32,68.66,68.66,0.0,65.17,34.08,8.18,10.49,54.27,5.19,11.53,27.91,4.84,9.17,21.28,0.0,0.0,0.22161 +base-hvac-floor-furnace-propane-only.xml,76.65,29.96,8.29,10.49,47.71,5.23,11.52,34.88,4.84,9.17,21.28,0.0,0.0,0.22161,157.67,9052.38,5681.45,1.0106,57.41,1.0,57.41,76.65,76.65,0.0,51.32,1.0,51.32,76.65,76.65,0.0,72.76,34.08,8.18,10.49,54.27,5.19,11.53,34.88,4.84,9.17,21.28,0.0,0.0,0.22161 +base-hvac-furnace-elec-only.xml,111.65,29.96,8.29,10.49,23.26,5.23,11.52,37.73,4.84,9.17,21.28,0.0,0.0,0.21906,109.05,6260.51,5681.45,1.0104,54.86,1.0,54.86,111.65,111.65,0.0,49.26,1.0,49.26,111.65,111.65,0.0,106.5,34.08,8.18,10.49,26.24,5.19,11.53,37.73,4.84,9.17,21.28,0.0,0.0,0.21906 +base-hvac-furnace-gas-only.xml,78.84,29.96,8.29,10.49,47.71,5.23,11.52,40.11,4.84,9.17,21.28,0.0,0.0,0.22161,151.38,8691.32,5681.45,1.0106,57.41,1.0,57.41,78.84,78.84,0.0,51.32,1.0,51.32,78.84,78.84,0.0,74.84,34.08,8.18,10.49,54.27,5.19,11.53,40.11,4.84,9.17,21.28,0.0,0.0,0.22161 +base-hvac-ground-to-air-heat-pump-cooling-only.xml,82.58,29.96,8.29,10.49,47.71,4.31,11.52,44.41,3.13,9.17,21.28,0.0,0.0,0.22146,162.45,9194.32,5600.77,1.0105,69.78,1.0,69.78,82.58,82.58,0.0,58.33,1.0,58.33,82.58,82.58,0.0,78.42,34.08,8.18,10.49,54.27,4.27,11.53,44.41,3.13,9.17,21.28,0.0,0.0,0.22146 +base-hvac-ground-to-air-heat-pump-heating-only.xml,69.78,29.96,8.29,10.49,23.26,5.23,11.52,12.72,4.84,9.17,21.28,0.0,0.0,0.21906,69.6,3995.45,5681.45,1.0104,54.86,1.0,54.86,69.78,69.78,0.0,49.26,1.0,49.26,69.78,69.78,0.0,66.4,34.08,8.18,10.49,26.24,5.19,11.53,12.72,4.84,9.17,21.28,0.0,0.0,0.21906 +base-hvac-ground-to-air-heat-pump.xml,65.62,29.96,8.3,10.49,22.48,4.42,11.52,11.11,3.22,9.17,21.28,0.0,0.0,0.21969,66.52,3721.93,5537.46,1.0105,51.84,1.0,51.84,65.62,65.62,0.0,45.87,1.0,45.87,65.62,65.62,0.0,62.51,34.08,8.19,10.49,25.3,4.37,11.53,11.11,3.22,9.17,21.28,0.0,0.0,0.21969 +base-hvac-install-quality-air-to-air-heat-pump-1-speed.xml,82.23,29.96,8.3,10.49,22.48,4.42,11.52,20.43,3.41,9.17,21.28,0.0,0.0,0.21969,81.98,4587.26,5537.46,1.0105,51.84,1.0,51.84,82.23,82.23,0.0,45.87,1.0,45.87,82.23,82.23,0.0,78.45,34.08,8.19,10.49,25.3,4.37,11.53,20.43,3.41,9.17,21.28,0.0,0.0,0.21969 +base-hvac-install-quality-furnace-gas-central-ac-1-speed.xml,78.34,29.96,8.29,10.49,47.71,5.17,11.52,39.63,4.72,9.17,21.28,0.0,0.0,0.22114,154.4,8640.01,5537.46,1.0105,56.29,1.0,56.29,78.34,78.34,0.0,49.72,1.0,49.72,78.34,78.34,0.0,74.39,34.08,8.18,10.49,54.27,5.12,11.53,39.63,4.72,9.17,21.28,0.0,0.0,0.22114 +base-hvac-install-quality-ground-to-air-heat-pump.xml,64.16,29.96,8.3,10.49,22.48,4.42,11.52,11.0,2.7,9.17,21.28,0.0,0.0,0.21969,65.67,3674.24,5537.46,1.0105,51.84,1.0,51.84,64.16,64.16,0.0,45.87,1.0,45.87,64.16,64.16,0.0,61.13,34.08,8.19,10.49,25.3,4.37,11.53,11.0,2.7,9.17,21.28,0.0,0.0,0.21969 +base-hvac-install-quality-mini-split-air-conditioner-only-ducted.xml,80.62,29.96,8.29,10.49,47.71,5.23,11.52,44.41,2.85,9.17,21.28,0.0,0.0,0.22161,159.94,9182.9,5681.45,1.0106,71.26,1.0,71.26,80.62,80.62,0.0,59.72,1.0,59.72,80.62,80.62,0.0,76.55,34.08,8.18,10.49,54.27,5.19,11.53,44.41,2.85,9.17,21.28,0.0,0.0,0.22161 +base-hvac-install-quality-mini-split-heat-pump-ducted.xml,64.45,29.96,8.3,10.49,22.48,4.42,11.52,12.11,2.03,9.17,21.28,0.0,0.0,0.21969,66.81,3738.53,5537.46,1.0105,51.84,1.0,51.84,64.45,64.45,0.0,45.87,1.0,45.87,64.45,64.45,0.0,61.42,34.08,8.19,10.49,25.3,4.37,11.53,12.11,2.03,9.17,21.28,0.0,0.0,0.21969 +base-hvac-mini-split-air-conditioner-only-ducted.xml,80.8,29.96,8.29,10.49,47.71,5.23,11.52,44.41,2.94,9.17,21.28,0.0,0.0,0.22161,160.05,9189.22,5681.45,1.0106,71.26,1.0,71.26,80.8,80.8,0.0,59.72,1.0,59.72,80.8,80.8,0.0,76.72,34.08,8.18,10.49,54.27,5.19,11.53,44.41,2.94,9.17,21.28,0.0,0.0,0.22161 +base-hvac-mini-split-air-conditioner-only-ductless.xml,78.98,29.96,8.29,10.49,47.71,5.23,11.52,44.41,2.06,9.17,21.28,0.0,0.0,0.22161,158.95,9125.96,5681.45,1.0106,71.26,1.0,71.26,78.98,78.98,0.0,59.72,1.0,59.72,78.98,78.98,0.0,75.01,34.08,8.18,10.49,54.27,5.19,11.53,44.41,2.06,9.17,21.28,0.0,0.0,0.22161 +base-hvac-mini-split-heat-pump-ducted-cooling-only.xml,79.98,29.96,8.29,10.49,47.71,4.31,11.52,44.41,2.09,9.17,21.28,0.0,0.0,0.22146,161.08,9117.04,5600.77,1.0105,69.78,1.0,69.78,79.98,79.98,0.0,58.33,1.0,58.33,79.98,79.98,0.0,75.95,34.08,8.18,10.49,54.27,4.27,11.53,44.41,2.09,9.17,21.28,0.0,0.0,0.22146 +base-hvac-mini-split-heat-pump-ducted-heating-only.xml,69.4,29.96,8.29,10.49,23.26,5.23,11.52,12.49,4.84,9.17,21.28,0.0,0.0,0.21906,69.49,3989.34,5681.45,1.0104,54.86,1.0,54.86,69.4,69.4,0.0,49.26,1.0,49.26,69.4,69.4,0.0,66.04,34.08,8.18,10.49,26.24,5.19,11.53,12.49,4.84,9.17,21.28,0.0,0.0,0.21906 +base-hvac-mini-split-heat-pump-ducted.xml,65.11,29.96,8.3,10.49,22.48,4.42,11.52,12.4,2.1,9.17,21.28,0.0,0.0,0.21969,67.37,3769.5,5537.46,1.0105,51.84,1.0,51.84,65.11,65.11,0.0,45.87,1.0,45.87,65.11,65.11,0.0,62.06,34.08,8.19,10.49,25.3,4.37,11.53,12.4,2.1,9.17,21.28,0.0,0.0,0.21969 +base-hvac-mini-split-heat-pump-ductless.xml,57.48,29.96,8.3,10.49,22.48,4.42,11.52,8.95,1.42,9.17,21.28,0.0,0.0,0.21969,60.84,3404.26,5537.46,1.0105,51.84,1.0,51.84,57.48,57.48,0.0,45.87,1.0,45.87,57.48,57.48,0.0,54.75,34.08,8.19,10.49,25.3,4.37,11.53,8.95,1.42,9.17,21.28,0.0,0.0,0.21969 +base-hvac-multiple.xml,92.81,30.0,8.31,10.49,35.97,7.13,11.52,42.72,5.1,9.17,21.28,0.0,0.0,0.2121,133.49,8342.29,6187.05,1.0101,54.85,1.0,54.85,92.81,92.81,0.0,49.85,1.0,49.85,92.81,92.81,0.0,89.1,34.1,8.19,10.49,40.27,7.12,11.53,42.72,5.1,9.17,21.28,0.0,0.0,0.2121 base-hvac-none.xml,89.45,0.0,44.15,5.18,0.0,25.15,6.1,0.0,25.79,4.82,15.13,0.0,0.0,0.19184,,,,,68.96,1.0,68.96,89.45,89.45,0.0,62.02,1.0,62.02,89.45,89.45,0.0,89.42,0.0,44.14,5.18,0.0,25.16,6.1,0.0,25.79,4.82,15.13,0.0,0.0,0.19184 -base-hvac-portable-heater-gas-only.xml,68.66,29.96,8.29,10.49,47.71,5.23,11.52,27.91,4.84,9.17,21.28,0.0,0.0,0.22161,121.24,6960.74,5681.45,1.0106,57.41,1.0,57.41,68.66,68.66,0.0,50.48,1.0,50.48,68.66,68.66,0.0,65.17,34.08,8.18,10.49,54.27,5.19,11.53,27.91,4.84,9.17,21.28,0.0,0.0,0.22161 -base-hvac-programmable-thermostat.xml,76.22,29.96,8.29,10.49,47.71,5.17,11.52,37.49,4.48,9.17,21.28,0.0,0.0,0.22114,148.31,8298.95,5537.46,1.0105,56.29,1.0,56.29,76.22,76.22,0.0,48.86,1.0,48.86,76.22,76.22,0.0,72.37,34.08,8.18,10.49,54.27,5.12,11.53,37.49,4.48,9.17,21.28,0.0,0.0,0.22114 -base-hvac-ptac-with-heating-electricity.xml,93.78,29.96,8.3,10.49,22.48,4.91,11.52,27.91,3.16,9.17,21.28,0.0,0.0,0.21989,93.04,5238.95,5572.71,1.0105,51.74,1.0,51.74,93.78,93.78,0.0,45.08,1.0,45.08,93.78,93.78,0.0,89.57,34.08,8.19,10.49,25.3,4.86,11.53,27.91,3.16,9.17,21.28,0.0,0.0,0.21989 -base-hvac-ptac-with-heating-natural-gas.xml,72.68,29.96,8.25,10.49,47.71,5.68,11.52,34.88,3.16,9.17,21.28,0.0,0.0,0.22136,139.44,7852.44,5572.71,1.0105,56.22,1.0,56.22,72.68,72.68,0.0,48.8,1.0,48.8,72.68,72.68,0.0,69.01,34.08,8.15,10.49,54.27,5.63,11.53,34.88,3.16,9.17,21.28,0.0,0.0,0.22136 -base-hvac-ptac.xml,80.76,29.96,8.25,10.49,47.71,5.68,11.52,44.41,3.16,9.17,21.28,0.0,0.0,0.22136,159.21,9192.85,5713.65,1.0105,71.22,1.0,71.22,80.76,80.76,0.0,58.26,1.0,58.26,80.76,80.76,0.0,76.68,34.08,8.15,10.49,54.27,5.63,11.53,44.41,3.16,9.17,21.28,0.0,0.0,0.22136 -base-hvac-pthp.xml,66.21,29.96,8.3,10.49,22.48,4.91,11.52,12.11,3.06,9.17,21.28,0.0,0.0,0.21989,67.61,3806.95,5572.71,1.0105,51.74,1.0,51.74,66.21,66.21,0.0,45.08,1.0,45.08,66.21,66.21,0.0,63.09,34.08,8.19,10.49,25.3,4.86,11.53,12.11,3.06,9.17,21.28,0.0,0.0,0.21989 -base-hvac-room-ac-only-ceer.xml,82.32,29.96,8.25,10.49,47.71,5.68,11.52,44.41,3.99,9.17,21.28,0.0,0.0,0.22136,160.24,9252.11,5713.65,1.0105,71.22,1.0,71.22,82.32,82.32,0.0,58.26,1.0,58.26,82.32,82.32,0.0,78.16,34.08,8.15,10.49,54.27,5.63,11.53,44.41,3.99,9.17,21.28,0.0,0.0,0.22136 -base-hvac-room-ac-only.xml,82.3,29.96,8.25,10.49,47.71,5.68,11.52,44.41,3.98,9.17,21.28,0.0,0.0,0.22136,160.23,9251.57,5713.65,1.0105,71.22,1.0,71.22,82.3,82.3,0.0,58.26,1.0,58.26,82.3,82.3,0.0,78.14,34.08,8.15,10.49,54.27,5.63,11.53,44.41,3.98,9.17,21.28,0.0,0.0,0.22136 -base-hvac-room-ac-with-heating.xml,95.58,29.96,8.3,10.49,22.48,4.91,11.52,27.91,3.98,9.17,21.28,0.0,0.0,0.21989,94.08,5297.67,5572.71,1.0105,51.74,1.0,51.74,95.58,95.58,0.0,45.08,1.0,45.08,95.58,95.58,0.0,91.27,34.08,8.19,10.49,25.3,4.86,11.53,27.91,3.98,9.17,21.28,0.0,0.0,0.21989 -base-hvac-room-ac-with-reverse-cycle.xml,66.21,29.96,8.3,10.49,22.48,4.91,11.52,12.11,3.06,9.17,21.28,0.0,0.0,0.21989,67.61,3806.95,5572.71,1.0105,51.74,1.0,51.74,66.21,66.21,0.0,45.08,1.0,45.08,66.21,66.21,0.0,63.09,34.08,8.19,10.49,25.3,4.86,11.53,12.11,3.06,9.17,21.28,0.0,0.0,0.21989 -base-hvac-stove-wood-pellets-only.xml,76.63,29.96,8.29,10.49,47.71,5.23,11.52,34.86,4.84,9.17,21.28,0.0,0.0,0.22161,,,,,57.41,1.0,57.41,76.63,76.63,0.0,50.48,1.0,50.48,76.63,76.63,0.0,72.74,34.08,8.18,10.49,54.27,5.19,11.53,34.86,4.84,9.17,21.28,0.0,0.0,0.22161 -base-hvac-undersized.xml,73.93,29.96,8.29,10.49,47.71,5.17,11.52,34.49,4.47,9.17,21.28,0.0,0.0,0.22114,140.33,7852.63,5537.46,1.0105,56.29,1.0,56.29,73.93,73.93,0.0,48.86,1.0,48.86,73.93,73.93,0.0,70.2,34.08,8.18,10.49,54.27,5.12,11.53,34.49,4.47,9.17,21.28,0.0,0.0,0.22114 -base-hvac-wall-furnace-elec-only.xml,96.16,29.96,8.29,10.49,23.26,5.23,11.52,28.48,4.84,9.17,21.28,0.0,0.0,0.21906,94.53,5426.46,5681.45,1.0104,54.86,1.0,54.86,96.16,96.16,0.0,48.61,1.0,48.61,96.16,96.16,0.0,91.67,34.08,8.18,10.49,26.24,5.19,11.53,28.48,4.84,9.17,21.28,0.0,0.0,0.21906 -base-lighting-ceiling-fans.xml,78.87,29.94,7.99,10.49,47.68,5.02,11.52,39.53,4.92,9.17,21.8,0.0,0.0,0.2188,153.41,8666.58,5591.04,1.0104,56.31,1.0,56.31,78.87,78.87,0.0,48.9,1.0,48.9,78.87,78.87,0.0,74.92,34.06,7.86,10.49,54.24,4.96,11.52,39.53,4.92,9.17,21.8,0.0,0.0,0.2188 +base-hvac-portable-heater-gas-only.xml,68.66,29.96,8.29,10.49,47.71,5.23,11.52,27.91,4.84,9.17,21.28,0.0,0.0,0.22161,121.24,6960.74,5681.45,1.0106,57.41,1.0,57.41,68.66,68.66,0.0,51.32,1.0,51.32,68.66,68.66,0.0,65.17,34.08,8.18,10.49,54.27,5.19,11.53,27.91,4.84,9.17,21.28,0.0,0.0,0.22161 +base-hvac-programmable-thermostat.xml,76.22,29.96,8.29,10.49,47.71,5.17,11.52,37.49,4.48,9.17,21.28,0.0,0.0,0.22114,148.31,8298.95,5537.46,1.0105,56.29,1.0,56.29,76.22,76.22,0.0,49.72,1.0,49.72,76.22,76.22,0.0,72.37,34.08,8.18,10.49,54.27,5.12,11.53,37.49,4.48,9.17,21.28,0.0,0.0,0.22114 +base-hvac-ptac-with-heating-electricity.xml,93.78,29.96,8.3,10.49,22.48,4.91,11.52,27.91,3.16,9.17,21.28,0.0,0.0,0.21989,93.04,5238.95,5572.71,1.0105,51.74,1.0,51.74,93.78,93.78,0.0,45.71,1.0,45.71,93.78,93.78,0.0,89.57,34.08,8.19,10.49,25.3,4.86,11.53,27.91,3.16,9.17,21.28,0.0,0.0,0.21989 +base-hvac-ptac-with-heating-natural-gas.xml,72.68,29.96,8.25,10.49,47.71,5.68,11.52,34.88,3.16,9.17,21.28,0.0,0.0,0.22136,139.44,7852.44,5572.71,1.0105,56.22,1.0,56.22,72.68,72.68,0.0,49.65,1.0,49.65,72.68,72.68,0.0,69.01,34.08,8.15,10.49,54.27,5.63,11.53,34.88,3.16,9.17,21.28,0.0,0.0,0.22136 +base-hvac-ptac.xml,80.76,29.96,8.25,10.49,47.71,5.68,11.52,44.41,3.16,9.17,21.28,0.0,0.0,0.22136,159.21,9192.85,5713.65,1.0105,71.22,1.0,71.22,80.76,80.76,0.0,59.69,1.0,59.69,80.76,80.76,0.0,76.68,34.08,8.15,10.49,54.27,5.63,11.53,44.41,3.16,9.17,21.28,0.0,0.0,0.22136 +base-hvac-pthp.xml,66.21,29.96,8.3,10.49,22.48,4.91,11.52,12.11,3.06,9.17,21.28,0.0,0.0,0.21989,67.61,3806.95,5572.71,1.0105,51.74,1.0,51.74,66.21,66.21,0.0,45.71,1.0,45.71,66.21,66.21,0.0,63.09,34.08,8.19,10.49,25.3,4.86,11.53,12.11,3.06,9.17,21.28,0.0,0.0,0.21989 +base-hvac-room-ac-only-ceer.xml,82.32,29.96,8.25,10.49,47.71,5.68,11.52,44.41,3.99,9.17,21.28,0.0,0.0,0.22136,160.24,9252.11,5713.65,1.0105,71.22,1.0,71.22,82.32,82.32,0.0,59.69,1.0,59.69,82.32,82.32,0.0,78.16,34.08,8.15,10.49,54.27,5.63,11.53,44.41,3.99,9.17,21.28,0.0,0.0,0.22136 +base-hvac-room-ac-only.xml,82.3,29.96,8.25,10.49,47.71,5.68,11.52,44.41,3.98,9.17,21.28,0.0,0.0,0.22136,160.23,9251.57,5713.65,1.0105,71.22,1.0,71.22,82.3,82.3,0.0,59.69,1.0,59.69,82.3,82.3,0.0,78.14,34.08,8.15,10.49,54.27,5.63,11.53,44.41,3.98,9.17,21.28,0.0,0.0,0.22136 +base-hvac-room-ac-with-heating.xml,95.58,29.96,8.3,10.49,22.48,4.91,11.52,27.91,3.98,9.17,21.28,0.0,0.0,0.21989,94.08,5297.67,5572.71,1.0105,51.74,1.0,51.74,95.58,95.58,0.0,45.71,1.0,45.71,95.58,95.58,0.0,91.27,34.08,8.19,10.49,25.3,4.86,11.53,27.91,3.98,9.17,21.28,0.0,0.0,0.21989 +base-hvac-room-ac-with-reverse-cycle.xml,66.21,29.96,8.3,10.49,22.48,4.91,11.52,12.11,3.06,9.17,21.28,0.0,0.0,0.21989,67.61,3806.95,5572.71,1.0105,51.74,1.0,51.74,66.21,66.21,0.0,45.71,1.0,45.71,66.21,66.21,0.0,63.09,34.08,8.19,10.49,25.3,4.86,11.53,12.11,3.06,9.17,21.28,0.0,0.0,0.21989 +base-hvac-stove-wood-pellets-only.xml,76.63,29.96,8.29,10.49,47.71,5.23,11.52,34.86,4.84,9.17,21.28,0.0,0.0,0.22161,,,,,57.41,1.0,57.41,76.63,76.63,0.0,51.32,1.0,51.32,76.63,76.63,0.0,72.74,34.08,8.18,10.49,54.27,5.19,11.53,34.86,4.84,9.17,21.28,0.0,0.0,0.22161 +base-hvac-undersized.xml,73.93,29.96,8.29,10.49,47.71,5.17,11.52,34.49,4.47,9.17,21.28,0.0,0.0,0.22114,140.33,7852.63,5537.46,1.0105,56.29,1.0,56.29,73.93,73.93,0.0,49.72,1.0,49.72,73.93,73.93,0.0,70.2,34.08,8.18,10.49,54.27,5.12,11.53,34.49,4.47,9.17,21.28,0.0,0.0,0.22114 +base-hvac-wall-furnace-elec-only.xml,96.16,29.96,8.29,10.49,23.26,5.23,11.52,28.48,4.84,9.17,21.28,0.0,0.0,0.21906,94.53,5426.46,5681.45,1.0104,54.86,1.0,54.86,96.16,96.16,0.0,49.26,1.0,49.26,96.16,96.16,0.0,91.67,34.08,8.18,10.49,26.24,5.19,11.53,28.48,4.84,9.17,21.28,0.0,0.0,0.21906 +base-lighting-ceiling-fans.xml,78.87,29.94,7.99,10.49,47.68,5.02,11.52,39.53,4.92,9.17,21.8,0.0,0.0,0.2188,153.41,8666.58,5591.04,1.0104,56.31,1.0,56.31,78.87,78.87,0.0,49.75,1.0,49.75,78.87,78.87,0.0,74.92,34.06,7.86,10.49,54.24,4.96,11.52,39.53,4.92,9.17,21.8,0.0,0.0,0.2188 base-location-baltimore-md.xml,68.24,20.38,10.81,9.61,32.63,6.84,10.82,17.61,6.93,8.65,15.13,0.0,0.0,0.27103,70.98,8871.19,11654.28,1.0725,51.28,1.0,51.28,68.24,68.24,0.0,48.55,1.0,48.55,68.24,68.24,0.0,67.26,21.17,10.76,9.61,33.88,6.87,10.82,17.61,6.93,8.65,15.13,0.0,0.0,0.27103 base-location-capetown-zaf.xml,78.44,4.28,4.51,8.35,6.85,2.53,9.47,0.85,4.2,7.63,15.13,0.0,0.0,0.16876,,,,,50.95,1.0,50.95,78.44,78.44,0.0,48.68,1.0,48.68,78.44,78.44,0.0,77.77,4.71,4.34,8.35,7.55,2.44,9.47,0.85,4.2,7.63,15.13,0.0,0.0,0.16876 base-location-dallas-tx.xml,67.27,9.51,26.3,7.53,15.24,15.86,8.51,4.08,13.07,6.82,15.13,0.0,0.0,0.27126,70.68,5742.03,7574.5,1.0725,47.17,1.0,47.17,67.27,67.27,0.0,44.36,1.0,44.36,67.27,67.27,0.0,66.36,10.03,26.36,7.53,16.06,16.05,8.51,4.08,13.07,6.82,15.13,0.0,0.0,0.27126 -base-location-duluth-mn.xml,72.0,45.19,1.79,13.08,71.99,2.11,14.52,57.38,2.41,11.61,15.13,0.0,0.0,0.25606,156.64,10592.13,6329.5,1.0683,53.97,1.0,53.97,72.0,72.0,0.0,44.9,1.0,44.9,72.0,72.0,0.0,67.65,50.31,1.6,13.08,80.15,2.02,14.52,57.38,2.41,11.61,15.13,0.0,0.0,0.25606 -base-location-helena-mt.xml,77.85,48.72,3.17,11.9,77.6,2.47,12.95,65.37,2.25,10.34,21.28,0.0,0.0,0.22273,200.52,11716.1,5781.4,1.0106,57.83,1.0,57.83,77.85,77.85,0.0,48.55,1.0,48.55,77.85,77.85,0.0,72.48,55.58,2.99,11.9,88.52,2.38,12.95,65.37,2.25,10.34,21.28,0.0,0.0,0.22273 +base-location-duluth-mn.xml,72.0,45.19,1.79,13.08,71.99,2.11,14.52,57.38,2.41,11.61,15.13,0.0,0.0,0.25606,156.64,10592.13,6329.5,1.0683,53.97,1.0,53.97,72.0,72.0,0.0,45.89,1.0,45.89,72.0,72.0,0.0,67.65,50.31,1.6,13.08,80.15,2.02,14.52,57.38,2.41,11.61,15.13,0.0,0.0,0.25606 +base-location-helena-mt.xml,77.85,48.72,3.17,11.9,77.6,2.47,12.95,65.37,2.25,10.34,21.28,0.0,0.0,0.22273,200.52,11716.1,5781.4,1.0106,57.83,1.0,57.83,77.85,77.85,0.0,49.57,1.0,49.57,77.85,77.85,0.0,72.48,55.58,2.99,11.9,88.52,2.38,12.95,65.37,2.25,10.34,21.28,0.0,0.0,0.22273 base-location-honolulu-hi.xml,78.61,0.0,44.15,5.18,0.0,24.88,6.1,0.0,21.1,4.82,15.13,0.0,0.0,0.19004,,,,,61.77,1.0,61.77,78.61,78.61,0.0,40.91,1.0,40.91,78.61,78.61,0.0,78.58,0.0,44.14,5.18,0.0,24.89,6.1,0.0,21.1,4.82,15.13,0.0,0.0,0.19004 base-location-miami-fl.xml,75.54,0.04,42.12,5.34,0.07,24.81,6.26,0.0,19.95,4.95,15.13,0.0,0.0,0.20669,75.23,5918.99,7459.06,1.0548,62.9,1.0,62.9,75.54,75.54,0.0,42.51,1.0,42.51,75.54,75.54,0.0,75.54,0.04,42.12,5.34,0.07,24.81,6.26,0.0,19.95,4.95,15.13,0.0,0.0,0.20669 base-location-phoenix-az.xml,70.41,1.3,50.54,5.61,2.08,29.01,6.56,0.07,22.07,5.19,15.13,0.0,0.0,0.27824,70.13,4733.06,6280.9,1.0745,49.97,1.0,49.97,70.41,70.41,0.0,45.22,1.0,45.22,70.41,70.41,0.0,70.33,1.32,50.59,5.61,2.12,29.05,6.56,0.07,22.07,5.19,15.13,0.0,0.0,0.27824 -base-location-portland-or.xml,75.19,12.93,3.75,9.98,20.72,2.67,11.26,15.34,3.0,9.08,15.13,0.0,0.0,0.18822,132.25,4002.47,2882.99,1.0498,65.95,1.0,65.95,75.19,75.19,0.0,49.57,1.0,49.57,75.19,75.19,0.0,73.91,13.78,3.64,9.98,22.07,2.62,11.26,15.34,3.0,9.08,15.13,0.0,0.0,0.18822 -base-mechvent-balanced.xml,83.17,29.56,8.47,10.49,47.07,5.26,11.52,43.62,5.16,9.17,21.28,1.79,0.0,0.22114,164.43,9392.47,5652.7,1.0105,56.29,1.0,56.29,83.17,83.17,0.0,48.86,1.0,48.86,83.17,83.17,0.0,79.06,33.67,8.35,10.49,53.62,5.21,11.53,43.62,5.16,9.17,21.28,1.79,0.0,0.22114 -base-mechvent-cfis-airflow-fraction-zero.xml,79.77,29.69,8.41,10.49,47.29,5.23,11.52,38.19,5.28,9.17,21.28,1.75,0.0,0.22114,151.71,8606.06,5613.55,1.0105,56.29,1.0,56.29,79.77,79.77,0.0,48.86,1.0,48.86,79.77,79.77,0.0,75.79,33.81,8.29,10.49,53.84,5.18,11.53,38.19,5.28,9.17,21.28,1.75,0.0,0.22114 -base-mechvent-cfis-supplemental-fan-exhaust.xml,76.47,29.69,8.41,10.49,47.29,5.23,11.52,36.32,5.13,9.17,21.28,0.5,0.0,0.22114,144.9,8219.72,5613.55,1.0105,56.29,1.0,56.29,76.47,76.47,0.0,48.86,1.0,48.86,76.47,76.47,0.0,72.66,33.81,8.29,10.49,53.84,5.18,11.53,36.32,5.13,9.17,21.28,0.5,0.0,0.22114 -base-mechvent-cfis.xml,80.57,29.69,8.41,10.49,47.29,5.23,11.52,39.41,5.24,9.17,21.28,1.72,0.0,0.22114,154.75,8778.61,5613.55,1.0105,56.29,1.0,56.29,80.57,80.57,0.0,48.86,1.0,48.86,80.57,80.57,0.0,76.56,33.81,8.29,10.49,53.84,5.18,11.53,39.41,5.24,9.17,21.28,1.72,0.0,0.22114 -base-mechvent-erv-atre-asre.xml,71.91,29.39,8.55,10.49,46.8,5.3,11.52,28.64,5.36,9.17,21.28,1.79,0.0,0.22114,125.38,7224.37,5702.05,1.0105,56.29,1.0,56.29,71.91,71.91,0.0,48.86,1.0,48.86,71.91,71.91,0.0,68.38,33.49,8.43,10.49,53.34,5.24,11.53,28.64,5.36,9.17,21.28,1.79,0.0,0.22114 -base-mechvent-erv.xml,71.91,29.39,8.55,10.49,46.8,5.3,11.52,28.65,5.36,9.17,21.28,1.79,0.0,0.22114,125.39,7224.97,5702.05,1.0105,56.29,1.0,56.29,71.91,71.91,0.0,48.86,1.0,48.86,71.91,71.91,0.0,68.38,33.49,8.43,10.49,53.34,5.24,11.53,28.65,5.36,9.17,21.28,1.79,0.0,0.22114 -base-mechvent-exhaust.xml,79.04,29.69,8.41,10.49,47.29,5.23,11.52,39.11,5.12,9.17,21.28,0.9,0.0,0.22114,152.66,8659.79,5613.55,1.0105,56.29,1.0,56.29,79.04,79.04,0.0,48.86,1.0,48.86,79.04,79.04,0.0,75.1,33.81,8.29,10.49,53.84,5.18,11.53,39.11,5.12,9.17,21.28,0.9,0.0,0.22114 -base-mechvent-hrv-asre.xml,71.92,29.39,8.55,10.49,46.8,5.3,11.52,28.64,5.36,9.17,21.28,1.79,0.0,0.22114,125.38,7224.42,5702.05,1.0105,56.29,1.0,56.29,71.92,71.92,0.0,48.86,1.0,48.86,71.92,71.92,0.0,68.39,33.49,8.43,10.49,53.34,5.24,11.53,28.64,5.36,9.17,21.28,1.79,0.0,0.22114 -base-mechvent-hrv.xml,71.92,29.39,8.55,10.49,46.8,5.3,11.52,28.65,5.36,9.17,21.28,1.79,0.0,0.22114,125.39,7225.02,5702.05,1.0105,56.29,1.0,56.29,71.92,71.92,0.0,48.86,1.0,48.86,71.92,71.92,0.0,68.39,33.49,8.43,10.49,53.34,5.24,11.53,28.65,5.36,9.17,21.28,1.79,0.0,0.22114 -base-mechvent-multiple.xml,83.09,29.5,8.5,10.49,46.989999999999995,6.16,11.52,43.21,6.1,9.17,21.28,1.45,0.0,0.22131,163.07,9422.47,5717.8,1.0105,57.03,1.0,57.03,83.09,83.09,0.0,49.47,1.0,49.47,83.09,83.09,0.0,79.02,33.62,8.38,10.49,53.54,6.08,11.53,43.21,6.1,9.17,21.28,1.45,0.0,0.22131 -base-mechvent-supply.xml,78.78,29.69,8.41,10.49,47.29,5.23,11.52,38.48,5.22,9.17,21.28,0.9,0.0,0.22114,151.15,8574.42,5613.55,1.0105,56.29,1.0,56.29,78.78,78.78,0.0,48.86,1.0,48.86,78.78,78.78,0.0,74.86,33.81,8.29,10.49,53.84,5.18,11.53,38.48,5.22,9.17,21.28,0.9,0.0,0.22114 -base-mechvent-whole-house-fan.xml,77.38,29.96,8.29,10.49,47.71,5.17,11.52,39.7,3.6,9.17,21.28,0.0,0.0,0.22114,153.7,8600.52,5537.46,1.0105,56.29,1.0,56.29,77.38,77.38,0.0,48.86,1.0,48.86,77.38,77.38,0.0,73.48,34.08,8.18,10.49,54.27,5.12,11.53,39.7,3.6,9.17,21.28,0.0,0.0,0.22114 -base-misc-generators.xml,77.36,29.96,8.29,10.49,47.71,5.17,11.52,39.56,5.17,9.17,21.28,0.0,0.0,0.22114,194.34,10874.98,5537.46,1.0105,56.29,1.0,56.29,79.23,79.23,0.0,48.86,1.0,48.86,79.23,79.23,0.0,73.45,34.08,8.18,10.49,54.27,5.12,11.53,39.56,5.17,9.17,21.28,0.0,0.0,0.22114 -base-pv.xml,38.29,29.96,8.29,10.49,47.71,5.17,11.52,39.56,5.17,9.17,21.28,0.0,0.0,0.22114,121.96,6824.49,5537.46,1.0105,56.29,1.0,56.29,79.23,79.23,0.0,48.86,1.0,48.86,79.23,79.23,0.0,69.79,34.08,8.18,10.49,54.27,5.12,11.53,39.56,5.17,9.17,21.28,0.0,0.0,0.22114 +base-location-portland-or.xml,75.19,12.93,3.75,9.98,20.72,2.67,11.26,15.34,3.0,9.08,15.13,0.0,0.0,0.18822,132.25,4002.47,2882.99,1.0498,65.95,1.0,65.95,75.19,75.19,0.0,50.16,1.0,50.16,75.19,75.19,0.0,73.91,13.78,3.64,9.98,22.07,2.62,11.26,15.34,3.0,9.08,15.13,0.0,0.0,0.18822 +base-mechvent-balanced.xml,83.17,29.56,8.47,10.49,47.07,5.26,11.52,43.62,5.16,9.17,21.28,1.79,0.0,0.22114,164.43,9392.47,5652.7,1.0105,56.29,1.0,56.29,83.17,83.17,0.0,49.72,1.0,49.72,83.17,83.17,0.0,79.06,33.67,8.35,10.49,53.62,5.21,11.53,43.62,5.16,9.17,21.28,1.79,0.0,0.22114 +base-mechvent-cfis-airflow-fraction-zero.xml,79.77,29.69,8.41,10.49,47.29,5.23,11.52,38.19,5.28,9.17,21.28,1.75,0.0,0.22114,151.71,8606.06,5613.55,1.0105,56.29,1.0,56.29,79.77,79.77,0.0,49.72,1.0,49.72,79.77,79.77,0.0,75.79,33.81,8.29,10.49,53.84,5.18,11.53,38.19,5.28,9.17,21.28,1.75,0.0,0.22114 +base-mechvent-cfis-supplemental-fan-exhaust.xml,76.47,29.69,8.41,10.49,47.29,5.23,11.52,36.32,5.13,9.17,21.28,0.5,0.0,0.22114,144.9,8219.72,5613.55,1.0105,56.29,1.0,56.29,76.47,76.47,0.0,49.72,1.0,49.72,76.47,76.47,0.0,72.66,33.81,8.29,10.49,53.84,5.18,11.53,36.32,5.13,9.17,21.28,0.5,0.0,0.22114 +base-mechvent-cfis.xml,80.57,29.69,8.41,10.49,47.29,5.23,11.52,39.41,5.24,9.17,21.28,1.72,0.0,0.22114,154.75,8778.61,5613.55,1.0105,56.29,1.0,56.29,80.57,80.57,0.0,49.72,1.0,49.72,80.57,80.57,0.0,76.56,33.81,8.29,10.49,53.84,5.18,11.53,39.41,5.24,9.17,21.28,1.72,0.0,0.22114 +base-mechvent-erv-atre-asre.xml,71.91,29.39,8.55,10.49,46.8,5.3,11.52,28.64,5.36,9.17,21.28,1.79,0.0,0.22114,125.38,7224.37,5702.05,1.0105,56.29,1.0,56.29,71.91,71.91,0.0,49.72,1.0,49.72,71.91,71.91,0.0,68.38,33.49,8.43,10.49,53.34,5.24,11.53,28.64,5.36,9.17,21.28,1.79,0.0,0.22114 +base-mechvent-erv.xml,71.91,29.39,8.55,10.49,46.8,5.3,11.52,28.65,5.36,9.17,21.28,1.79,0.0,0.22114,125.39,7224.97,5702.05,1.0105,56.29,1.0,56.29,71.91,71.91,0.0,49.72,1.0,49.72,71.91,71.91,0.0,68.38,33.49,8.43,10.49,53.34,5.24,11.53,28.65,5.36,9.17,21.28,1.79,0.0,0.22114 +base-mechvent-exhaust.xml,79.04,29.69,8.41,10.49,47.29,5.23,11.52,39.11,5.12,9.17,21.28,0.9,0.0,0.22114,152.66,8659.79,5613.55,1.0105,56.29,1.0,56.29,79.04,79.04,0.0,49.72,1.0,49.72,79.04,79.04,0.0,75.1,33.81,8.29,10.49,53.84,5.18,11.53,39.11,5.12,9.17,21.28,0.9,0.0,0.22114 +base-mechvent-hrv-asre.xml,71.92,29.39,8.55,10.49,46.8,5.3,11.52,28.64,5.36,9.17,21.28,1.79,0.0,0.22114,125.38,7224.42,5702.05,1.0105,56.29,1.0,56.29,71.92,71.92,0.0,49.72,1.0,49.72,71.92,71.92,0.0,68.39,33.49,8.43,10.49,53.34,5.24,11.53,28.64,5.36,9.17,21.28,1.79,0.0,0.22114 +base-mechvent-hrv.xml,71.92,29.39,8.55,10.49,46.8,5.3,11.52,28.65,5.36,9.17,21.28,1.79,0.0,0.22114,125.39,7225.02,5702.05,1.0105,56.29,1.0,56.29,71.92,71.92,0.0,49.72,1.0,49.72,71.92,71.92,0.0,68.39,33.49,8.43,10.49,53.34,5.24,11.53,28.65,5.36,9.17,21.28,1.79,0.0,0.22114 +base-mechvent-multiple.xml,83.09,29.5,8.5,10.49,46.989999999999995,6.16,11.52,43.21,6.1,9.17,21.28,1.45,0.0,0.22131,163.07,9422.47,5717.8,1.0105,57.03,1.0,57.03,83.09,83.09,0.0,50.33,1.0,50.33,83.09,83.09,0.0,79.02,33.62,8.38,10.49,53.54,6.08,11.53,43.21,6.1,9.17,21.28,1.45,0.0,0.22131 +base-mechvent-supply.xml,78.78,29.69,8.41,10.49,47.29,5.23,11.52,38.48,5.22,9.17,21.28,0.9,0.0,0.22114,151.15,8574.42,5613.55,1.0105,56.29,1.0,56.29,78.78,78.78,0.0,49.72,1.0,49.72,78.78,78.78,0.0,74.86,33.81,8.29,10.49,53.84,5.18,11.53,38.48,5.22,9.17,21.28,0.9,0.0,0.22114 +base-mechvent-whole-house-fan.xml,77.38,29.96,8.29,10.49,47.71,5.17,11.52,39.7,3.6,9.17,21.28,0.0,0.0,0.22114,153.7,8600.52,5537.46,1.0105,56.29,1.0,56.29,77.38,77.38,0.0,49.72,1.0,49.72,77.38,77.38,0.0,73.48,34.08,8.18,10.49,54.27,5.12,11.53,39.7,3.6,9.17,21.28,0.0,0.0,0.22114 +base-misc-generators.xml,77.36,29.96,8.29,10.49,47.71,5.17,11.52,39.56,5.17,9.17,21.28,0.0,0.0,0.22114,194.34,10874.98,5537.46,1.0105,56.29,1.0,56.29,79.23,79.23,0.0,49.72,1.0,49.72,79.23,79.23,0.0,73.45,34.08,8.18,10.49,54.27,5.12,11.53,39.56,5.17,9.17,21.28,0.0,0.0,0.22114 +base-pv.xml,38.29,29.96,8.29,10.49,47.71,5.17,11.52,39.56,5.17,9.17,21.28,0.0,0.0,0.22114,121.96,6824.49,5537.46,1.0105,56.29,1.0,56.29,79.23,79.23,0.0,49.72,1.0,49.72,79.23,79.23,0.0,69.79,34.08,8.18,10.49,54.27,5.12,11.53,39.56,5.17,9.17,21.28,0.0,0.0,0.22114 base-version-co2-2019ABCD.xml,,,,,,,,,,,,,,,154.43,8641.78,5537.46,1.0105,,,,,,,,,,,,,,,,,,,,,,,,,, base-version-eri-2014.xml,78.43,31.33,8.26,11.44,49.84,4.26,12.37,37.59,4.09,11.49,21.71,0.0,0.0,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,, base-version-eri-2014A.xml,76.05,31.28,8.28,10.39,49.77,4.27,11.42,37.55,4.1,8.7,21.71,0.0,0.0,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,, @@ -180,4 +180,4 @@ base-version-eri-2019ABCD.xml,79.23,29.96,8.29,10.49,47.71,5.17,11.52,39.56,5.17 base-version-iecc-eri-2015.xml,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,74.5,31.28,8.28,10.39,49.77,4.27,11.42,37.97,4.05,8.7,21.04,0.0,0.0,0.24736 base-version-iecc-eri-2018.xml,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,72.0,34.02,8.21,10.39,54.13,4.25,11.42,37.97,4.05,8.7,21.04,0.0,0.0,0.24736 base-version-iecc-eri-2021.xml,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,75.23,34.08,8.18,10.49,54.27,5.12,11.53,39.56,5.17,9.17,21.28,0.0,0.0,0.22114 -base.xml,79.23,29.96,8.29,10.49,47.71,5.17,11.52,39.56,5.17,9.17,21.28,0.0,0.0,0.22114,154.43,8641.78,5537.46,1.0105,56.29,1.0,56.29,79.23,79.23,0.0,48.86,1.0,48.86,79.23,79.23,0.0,75.23,34.08,8.18,10.49,54.27,5.12,11.53,39.56,5.17,9.17,21.28,0.0,0.0,0.22114 +base.xml,79.23,29.96,8.29,10.49,47.71,5.17,11.52,39.56,5.17,9.17,21.28,0.0,0.0,0.22114,154.43,8641.78,5537.46,1.0105,56.29,1.0,56.29,79.23,79.23,0.0,49.72,1.0,49.72,79.23,79.23,0.0,75.23,34.08,8.18,10.49,54.27,5.12,11.53,39.56,5.17,9.17,21.28,0.0,0.0,0.22114 From b9b50b27d8c640dc1c42c03bc4b7623d4ceaa399 Mon Sep 17 00:00:00 2001 From: Scott Horowitz Date: Fri, 28 Jul 2023 12:05:24 -0600 Subject: [PATCH 4/4] Move changelog note to the correct version [ci skip] --- Changelog.md | 4 +++- 1 file changed, 3 insertions(+), 1 deletion(-) diff --git a/Changelog.md b/Changelog.md index 5da34f161..656482f75 100644 --- a/Changelog.md +++ b/Changelog.md @@ -4,6 +4,9 @@ __New Features__ - **Breaking change**: Disaggregates "EC_x Vent" and "EC_x Dehumid" from "EC_x L&A" in `ERI_Results.csv`. - Allow JSON output files instead of CSV via a new `--output-format JSON` commandline argument. +__Bugfixes__ +- ZERH Single Family v2 should use ASRE instead of SRE for mechanical ventilation fans. + ## OpenStudio-ERI v1.6.0 __New Features__ @@ -39,7 +42,6 @@ __Bugfixes__ - Adds error-checking to ensure that SFA/MF dwelling units have at least one attached wall/ceiling/floor surface. - Various Manual J HVAC autosizing calculation bugfixes and improvements. - Ensure that ductless HVAC systems do not have a non-zero airflow defect ratio specified. -- ZERH Single Family v2 uses ASRE instead of SRE for mechanical ventilation fans. ## OpenStudio-ERI v1.5.2