You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
What steps will reproduce the problem?
1. maxas.pl -i microbench.sass microbench.cubin
What is the expected output? What do you see instead?
Expected:
Kernel: microbench, Instructions: 17, Register Count: 20, Bank Conflicts: 0,
Reuse: 26.7% (4/15)
Actual:
REGISTER_MAPPING Error: Bad register number or range: 0a-20
Line: 0a-20 : out, clocks, in, tid, bid, blockDim, clock1, clock2, result, x
Full Context:
0a-20 : out, clocks, in, tid, bid, blockDim, clock1, clock2, result, x
What version of the product are you using? On what operating system?
Ubuntu 12.04 64-bit
Please provide any additional information below.
Maxas.pm expects decimal digits in the register mapping. If I change the range
to '10-32' it compiles without complaint.
Original issue reported on code.google.com by [email protected] on 12 Nov 2014 at 6:36
The text was updated successfully, but these errors were encountered:
Original issue reported on code.google.com by
[email protected]