rotational_minctracc.py should scale simplex to subject resolution #20

Open
mcvaneede opened this issue Oct 27, 2015 · 1 comment
Open

Comments

@mcvaneede
Copy link
Member

We just found out that because rotational_minctracc.py uses the default value for the simplex (20mm), this stage fails fairly often at SciNet. There is still the question why when the same command run at MICe we don't have this issue, but scaling the -simplex value to something reasonable (1mm), fixes the issue at SciNet.

@bcdarwin
Copy link
Member

bcdarwin commented Nov 3, 2015

The simplex is now settable with a default of 1 as of ffab864.