1- Install pypx
2- Install xinetd
apt-get install -y xinetd
3- Make sure directories used to store data exist
mkdir -p /tmp
mkdir -p /incoming/log
mkdir -p /incoming/data
4- Configure xinetd
You might have to change root
user to your actual username, i.e. chips
.
This user must have permission to write in the directories used to store data (/tmp, /incoming/log, /incoming/data)
echo "service dicomlistener
{
disable = no
socket_type = stream
wait = no
user = root
server = /usr/local/bin/px-listen
server_args = -e /usr/bin/storescp -t /tmp -l /incoming/log -d /incoming/data
type = UNLISTED
port = 10402
bind = 0.0.0.0
}" > /etc/xinetd.d/dicomlistener
5- Restart xinetd service
service xinetd restart
6- Test listener
# install network utils
apt-get install -y netcat
# connect to listening port
# this command must hang.
# if it returns, something is wrong
# if so, run "/usr/local/bin/px-listen -e /usr/bin/storescp -t /tmp -l /incoming/log -d /incoming/data" for more information
nc localhost 10402
Hit "ctl + c" to stop "nc localhost 10402".
A file should have been created in /incoming/log/
.
1- Install pypx
2- Add a new service:
In /etc/services
add the lines:
dicom-listener 10402/tcp # dicom listener
dicom-listener 10402/udp # dicom listener
# Nicolas Rannou <[email protected]>
3- Configure daemon:
Create /Library/LaunchDaemons/org.dicom.listener.plist
.
Make sure to replace username Nico
by your own username.
<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE plist PUBLIC "-//Apple//DTD PLIST 1.0//EN" "http://www.apple.com/DTDs/PropertyList-1.0.dtd">
<plist version="1.0">
<dict>
<key>UserName</key>
<string>nico</string>
<key>Label</key>
<string>org.dicom.listener</string>
<key>ProgramArguments</key>
<array>
<string>/Library/Frameworks/Python.framework/Versions/3.5/bin/python3</string>
<string>/Library/Frameworks/Python.framework/Versions/3.5/bin/px-listen</string>
<string>-t</string>
<string>/tmp</string>
<string>-l</string>
<string>/incoming/log</string>
<string>-d</string>
<string>/incoming/data</string>
</array>
<key>inetdCompatibility</key>
<dict>
<key>Wait</key>
<false/>
</dict>
<key>Sockets</key>
<dict>
<key>Listeners</key>
<dict>
<key>SockServiceName</key>
<string>dicom-listener</string>
<key>SockType</key>
<string>stream</string>
</dict>
</dict>
</dict>
</plist>
4- Load daemon
launchctl load -w org.dicom.listener.plist
#unload: launchctl unload org.dicom.listener.plist
5- Make sure directories used to store data exist
WARNING: The user listed in the /etc/xinetd.d/dicomlistener
or /Library/LaunchDaemons/org.dicom.listener.plist
file must have write access to the following directories:
mkdir -p /tmp
mkdir -p /incoming/log
mkdir -p /incoming/data
6- Test listener
# connect to listening port
# this command must hang.
# if it returns, something is wrong
# if so, run "/usr/local/bin/px-listen -e /usr/bin/storescp -t /tmp -l /incoming/log -d /incoming/data" for more information
nc localhost 10402
Hit "ctl + c" to stop "nc localhost 10402".
A file should have been created in /incoming/log/
.
If it hangs but no file was created, the user listed in the /etc/xinetd.d/dicomlistener
or /Library/LaunchDaemons/org.dicom.listener.plist
file probably doesn't have write
access to the /tmp/
, /incoming/data/
, /incoming/log/
directories.
See details on the offical website: http://www.orthanc-server.com/.
- Make sure to add a new entry in the "DicomModalities"
- in the orthanc configuration file before starting the server. See below.
-
Orthanc: host, Dicom listener: host.
-
- IP: "localhost"
-
- PORT: 10402
-
Orthanc: host, Dicom listener: dock
-
- IP: "localhost"
-
- PORT: 10402
-
Orthanc: dock, Dicom listener: dock
-
- IP: ("172.18.0.1" or something similar)
-
- PORT: 10402
-
Orthanc: dock, Dicom listener: host
-
- IP: ("192.168.0.10" or something similar)
-
- PORT: 10402
The following entry tells Orthanc to accept connection from "calling aet" (aet) CHIPS, and if "CHIPS" requires data to be moved (px-move
), the data will be pushed to IP:PORT
.
If Orthanc and Dicom listener are running on a dock:
"chips" : [ "CHIPS", "172.18.0.1", 10402 ]
1- Upload data to Orthanc. (default: http://localhost:8042)
2- Browse data in Orthanc web server.
3- Hit "send to remote modality'
4- Select chips
5- --- sending data ---
6- Make sure data has arrived and is organized in /incoming/data