In a previous version of CFE we enforced the use of traffic group None for VIP's that are intended to failover between AZ's in AWS. However now we see this unwanted behavior when using CFE:
Customer deploys our CFT in AWS for HA across AZ's.
Customer configures 2x VIPs in BIG-IP, one in each AZ. Because they are not intimate with our CFE requirements, they put these VIP's in traffic-group-1 which is default when using the GUI.
Customer configures secondary IP addresses on her ENI's in AWS to match the VIP configuration.
Customer configures an EIP with the correct tags so that this EIP is associated/re-associated with her 2x secondary IP addresses configured in Step 3. Everything is configured correctly except the VIPs are in Traffic Group 1, not None.
Customer tests failover. Because she has not created her VIP's in traffic group None, CFE does not perform failover successfully, and further it deletes the secondary IP addresses she had created for her VIPs.
Environment information
For bugs, enter the following information:
Cloud Failover Extension Version: 1.7
BIG-IP version: unknown
Cloud provider: AWS when failover is set up across AZ's with 1x EIP and 2x VIPs.
Severity Level
For bugs, enter the bug severity level. Do not set any labels.
Severity: 3
The text was updated successfully, but these errors were encountered:
@shyawnkarim you asked me for a qkview but the customer is using an eval key and is unable to open a support case and provide a qkview - sorry about that.
Do you already have an issue opened with F5 support?
No
Description
In a previous version of CFE we enforced the use of traffic group None for VIP's that are intended to failover between AZ's in AWS. However now we see this unwanted behavior when using CFE:
Environment information
For bugs, enter the following information:
Severity Level
For bugs, enter the bug severity level. Do not set any labels.
Severity: 3
The text was updated successfully, but these errors were encountered: