"__comment01__": "SERIAL PORT OF SEISMOGRAPH AND BAUD RATE (Linux ports are smth like /dev/ttyS0 and windows COM1)",
"serial_port": "COM4",
"serial_baud_rate": 57600,
"__comment02__": "INTERVAL (IN SECONDS) FOR SENDING PACKETS TO THE SEISMOGRAPH",
"send_data_period": 0.1,
"__comment03__": "CONVERSION FROM SEISMOGRAPH DATA TO ACCELERATION (m/s^2)",
"acceleration_data_range_min": -32768.0,
"acceleration_data_range_max": 32767.0,
"acceleration_mss_range_min": -19.6133,
"acceleration_mss_range_max": 19.6133,
"__comment04__": "LOW AND HIGH-PASS FILTER CUTOFF FREQUENCIES TO REMOVE EARTH ACCELERATION, ZERO DRIFT AND NOISE",
"low_pass_filter_cutoff": 15,
"high_pass_filter_cutoff": 0.1,
"__comment05__": "FOR HOW MANY CHUNKS (SECONDS) INTENSITY MUST EXCEED THE LOW THRESHOLD TO START ALARM",
"alarm_low_threshold_chunks": 2,
"__comment06__": "FOR HOW MANY CHUNKS (SECONDS) INTENSITY MUST EXCEED THE HIGH THRESHOLD TO START ALARM",
"alarm_high_threshold_chunks": 1,
"__comment07__": "MUST BE EQUAL TO REAL IMU SAMPLING RATE. CHUNK SIZE WILL BE EQUAL TO THAT VALUE, SO 1 CHUNK = 1S",
"sampling_rate": 40,
"__comment08__": "TIME (IN SECONDS) TO WAIT BEFORE PERFORMING INTENSITY CALIBRATION AFTER FIRST START",
"calibration_initial_delay": 30,
"__comment09__": "TIME (IN SECONDS) TO WAIT BEFORE PERFORMING INTENSITY CALIBRATION AFTER BUTTON PRESS",
"calibration_button_delay": 2,
"__comment10__": "CHUNKS (ALSO SECONDS) TO COLLECT INTENSITY CALIBRATION DATA",
"calibration_chunks": 10,
"__comment11__": "DIRECTORY WHERE TO SAVE RECORDED RAW DATA",
"samples_directory": "data",
"__comment12__": "RECORDING TO FILE BEGINS WHEN THE ALARM ACTIVATES IN THE LOW MODE. THIS SETTING INDICATES",
"__comment13__": "HOW MANY CHUNKS (SECONDS) WILL BE WRITTEN TO THE FILE BEFORE THE ALARM START",
"pre_recording_buffer_chunks": 10,
"__comment14__": "EVERY CHUNK (SECOND), THE PEAK (MAX) WILL MULTIPLY BY THIS COEFFICIENT TO GRADUALLY BECOME 0",
"peak_intensity_attenuation_factor": 0.998,
"__comment15__": "DEFAULT IP FOR FLASK SERVER. USE 0.0.0.0 TO RUN ON LOCALHOST AND NETWORK AT THE SAME TIME",
"flask_server_host": "0.0.0.0",
"__comment16__": "DEFAULT PORT FLASK SERVER. USE 5000 IF YOU ARE NOT ROOT",
"flask_server_port": 80
}