Notifications
You must be signed in to change notification settings - Fork 6
/
script_time_hotwater.lua
116 lines (102 loc) · 3.87 KB
/
script_time_hotwater.lua
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
-- script_time_hotwater.lua for Domoticz
-- Author: CreasolTech https://www.creasol.it
-- This LUA script manage the Hot Water Heat Pump (controlled by Modbus) to optimize own consumption from photovoltaic
-- Optionally it's possible to use a relay to enable power supply to the HW heat pump (to avoid power consumption during the night)
dofile "scripts/lua/globalvariables.lua" -- some variables common to all scripts
dofile "scripts/lua/globalfunctions.lua" -- some functions common to all scripts
DEBUG_LEVEL=E_INFO
--DEBUG_LEVEL=E_DEBUG -- remove "--" at the begin of line, to enable debugging
DEBUG_PREFIX="HotWater: "
commandArray={}
dofile "scripts/lua/config_hotwater.lua"
-- in peak hours => OFF
-- between 12:00 and Sunset:
-- between 12:00 and 14:00 ON only if enough power is available from photovoltaic
-- after 14:00, ON
if (HW_POWERSUPPLY~='') then
if (otherdevices[HW_POWERSUPPLY]==nil) then
log(E_WARNING,"HotWater power supply defined, but device does not exist: "..HW_POWERSUPPLY)
goto hotwaterEnd
elseif (otherdevices[HW_POWERSUPPLY]=='Off') then
log(E_DEBUG,"HotWater power supply disabled: exit")
goto hotwaterEnd
end
end
log(E_DEBUG,"====================== "..DEBUG_PREFIX.." ============================")
setPoint=tonumber(otherdevices[HW_SETPOINT])
if (setPoint==nil) then
log(E_WARNING,"Hardware disabled: exit!")
goto hotwaterEnd
end
setPointNew=setPoint
if (HW_MODE=='' or otherdevices[HW_MODE]==nil) then
log(E_ERROR, "Please create a selector switch with Off, On, Auto states")
return commandArray
end
mode=otherdevices[HW_MODE]
if (mode=='Off') then
if (setPoint>HW_SP_OFF) then
log(E_INFO,"Hot Water switched Off")
setPointNew=HW_SP_OFF
end
elseif (mode=='On') then
if (setPoint<HW_SP_MIN) then
log(E_INFO,"Hot Water switched On")
setPointNew=HW_SP_MIN
end
else
-- mode==Auto
setPointNew=HW_SP_OFF -- Default: OFF
if (peakPower()) then
if (setPoint>HW_SP_OFF) then
setPointNew=HW_SP_OFF
end
log(E_DEBUG, "Peak => setPoint="..setPointNew)
else
if (timeofday["Daytime"] and timeNow.hour>=10) then
-- during the day
hwPower=getPowerValue(otherdevices[HW_POWER])
gridPower=getPowerValue(otherdevices[GRID_POWER_DEV]) -- Grid power meter
pvPower=getPowerValue(otherdevices[PV_POWER_DEV]) -- Photovoltaic on the roof
pvGardenPower=getPowerValue(otherdevices[PVGARDEN_POWER_DEV]) -- Photovoltaic on the roof
availablePower=hwPower-gridPower-450
tempWaterBot=tonumber(otherdevices[HW_TEMPWATER_BOTTOM])
log(E_DEBUG, "DAY: gridPower="..gridPower.." pvPower="..pvPower.." pvGarden="..pvGardenPower.." hwPower="..hwPower.." tempWaterBot="..tempWaterBot)
if (availablePower>0) then
if (gridPower+pvPower<0) then
log(E_DEBUG,"Available power and PV in the garden is producing too much")
setPointNew=HW_SP_MAX
elseif (timeNow.hour>=12) then
log(E_DEBUG,"Available power and time >= 12")
setPointNew=HW_SP_MAX
else
setPointNew=HW_SP_NORMAL
end
else
if (timeNow.hour>=14) then
setPointNew=HW_SP_NORMAL
else
setPointNew=HW_SP_MIN
end
end
if (setPointNew>=HW_SP_NORMAL and otherdevices[EVSTATE_DEV]=='Ch') then
log(E_DEBUG,"EV is charging: reduce setpoint to HW_SP_NORMAL")
setPointNew=HW_SP_NORMAL
end
if (setPointNew>setPoint and hwPower<100) then
log(E_DEBUG,"HotWater is OFF and setPoint has been increased")
-- if HP_TEMPWATER_BOT + 15 > setPointNew => increase setPointNew to force start
if (tempWaterBot<setPointNew and tempWaterBot>=(setPointNew-15)) then
log(E_DEBUG,"Increase setpoint to tempWaterBot+15+1 to force heat pump start")
setPointNew=tempWaterBot+15+1
end
end
end
end
end
log(E_DEBUG,"Hot Water setpoint: "..setPoint.." -> "..setPointNew)
if (setPointNew ~= setPoint) then
commandArray[1]={['UpdateDevice']=tostring(otherdevices_idx[HW_SETPOINT])..'|1|'.. setPointNew}
end
::hotwaterEnd::
return commandArray