739 lines (690 loc) · 31.1 KB
/
script_time_heatpump.lua
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
670
671
672
673
674
675
676
677
678
679
680
681
682
683
684
685
686
687
688
689
690
691
692
693
694
695
696
697
698
699
700
701
702
703
704
705
706
707
708
709
710
711
712
713
714
715
716
717
718
719
720
721
722
723
724
725
726
727
728
729
730
731
732
733
734
735
736
737
738
739
-- Lua script for Domoticz, controlling the heating/cooling system by a heat pump supplied by electric grid + photovoltaic system.
-- Designed to consume as most as possible energy from photovoltaic
-- Written by Creasol, https://www.creasol.it , [email protected]
--
-- Please assure that
-- 127.0.0.1 is enabled to connect without authentication, in Domoticz -> Configuration -> Settings -> Local Networks (e.g. 127.0.0.1;192.168.1.*)
--
commandArray={}
dofile "/home/pi/domoticz/scripts/lua/config_heatpump.lua"
-- Level can be 0 (OFF) or >0 (ON: the higher the level, more power can be used by the heat pump)
-- Increment the level (available power for the heat pump)
function incLevel()
HP['Level']=HP['Level']+1
log(E_INFO,'Increment Level to '..HP['Level'])
end
-- Decrement the level to reduce heat pump power usage
function decLevel()
if (HP['Level']>0) then
HP['Level']=HP['Level']-1
log(E_INFO,'Decrement Level to '..HP['Level'])
else
HP['Level']=0
end
end
-- Initialize the HP domoticz variable (json coded, within several state variables)
function HPinit()
if (HP==nil) then HP={} end
if (HP['otmin']==nil) then HP['otmin']=10 end -- outodorTemperatureMin
if (HP['otmax']==nil) then HP['otmax']=10 end -- outodorTemperatureMin
if (HP['Level']==nil) then HP['Level']=0 end
if (HP['SPoff']==nil) then HP['SPoff']=0 end
if (HP['HPout']==nil) then HP['HPout']=0 end -- tempHPout temperature
if (HP['t']==nil) then HP['t']=0 end -- when HP works at max level, the level can be reduced only if the system ask to reduce it for at least 5 minutes
if (HP['trc']==nil) then HP['trc']=0 end -- disable the Valve_Radiant_Coil after 3 minutes from HeatPump going OFF
end
-- Initialize the HPZ domoticz variable (json coded, used to compute temperature tempDerivate of a zone that is always enabled)
function HPZinit()
if (HPZ==nil) then HPZ={} end
if (HPZ['temp']==nil) then HPZ['temp']=otherdevices[TempZoneAlwaysOn] end -- Temperature of a zone always ON, at the current hh:00 time
if (HPZ['t0']==nil) then HPZ['t0']=otherdevices[TempZoneAlwaysOn] end -- Temperature of a zone always ON, at the current hh:00 time
if (HPZ['t1']==nil) then HPZ['t1']=otherdevices[TempZoneAlwaysOn] end -- Temperature of a zone always ON, 1 hour ago (at hh-1:00)
if (HPZ['t2']==nil) then HPZ['t2']=otherdevices[TempZoneAlwaysOn] end -- Temperature of a zone always ON, 2 hour ago (at hh-1:00)
if (HPZ['t3']==nil) then HPZ['t3']=otherdevices[TempZoneAlwaysOn] end -- Temperature of a zone always ON, 3 hour ago (at hh-1:00)
if (HPZ['t4']==nil) then HPZ['t4']=otherdevices[TempZoneAlwaysOn] end -- Temperature of a zone always ON, 4 hour ago (at hh-1:00)
if (HPZ['gr']==nil) then HPZ['gr']=0 end -- tempDerivate for a zone always ON
end
-- switch ON/OFF valves to enable/disable zones
function updateValves()
-- check valveStateTemp and update valve status
for n,v in pairs(zones) do
-- v[ZONE_NAME]=zonename (HeatingSP_n = setpoint temperature)
-- v[ZONE_TEMP_DEV]=tempsensor
-- v[ZONE_VALVE]=valve device
-- v[ZONE_WINTER_START]=start time
-- v[ZONE_WINTER_STOP]=end time
-- v[ZONE_WINTER_OFFSET]=offset outside the time slot (start time..end time)
--
-- if HeatPump == Off => don't activate electrovalve
if (otherdevices[DEVlist[1][1] ]=='Off') then
valveStateTemp[v[ZONE_VALVE] ]='Off'
end
-- update commandArray only when valve status have changed
if (v[ZONE_VALVE]~=nil and v[ZONE_VALVE]~='' and valveStateTemp[v[ZONE_VALVE] ]~=nil and otherdevices[v[ZONE_VALVE] ]~=valveStateTemp[v[ZONE_VALVE] ]) then
if (valveStateTemp[v[ZONE_VALVE] ] == 'On') then
deviceOn(v[ZONE_VALVE],HP,'v'..n)
else
deviceOff(v[ZONE_VALVE],HP,'v'..n)
end
log(E_INFO,'**** Valve for zone '..v[ZONE_NAME]..' changed to '..valveStateTemp[ v[ZONE_VALVE] ])
end
end
end
monthnow = tonumber(os.date("%m"))
timenow = os.date("*t")
minutesnow = timenow.min + timenow.hour * 60
-- check variables
json=require("dkjson")
HPmode='Off' -- Default: don't heat/cool
if (otherdevices[HPMode] == nil) then
log(E_WARNING,"A device must be created by hand!\n***************** ERROR *****************\nSelector switch Off/Winter/Summer does not exist => must be created!\nGo to Setup -> Hardware, create a Dummy hardware (if not exists) and then Create virtual sensor, name '".. HPMode .. "' type Selector switch\nGo to Switches panel, edit the new device " .. HPMode .. " and rename level1 to 'Winter', level2 to 'Summer' and delete level 30")
else
if (otherdevices[HPMode] == 'Winter') then
HPmode='Winter'
elseif (otherdevices[HPMode] == 'Summer') then
HPmode='Summer'
elseif (otherdevices[HPMode] ~= 'Off') then
log(E_WARNING,"Device "..HPmode.." must have the following level names:\n0 => 'Off', 10 => 'Winter' and 20 => 'Summer'")
end
end
if (uservariables['zHeatPump'] == nil) then
-- initialize variable
HPinit() --init HP table
-- create a Domoticz variable, coded in json, within all variables used in this module
checkVar('zHeatPump',2,json.encode(HP))
else
HP=json.decode(uservariables['zHeatPump'])
HPinit() -- check that all variables in HP table are initialized
end
if (uservariables['zHeatPumpZone'] == nil) then
-- initialize variable
HPZinit() --init HPZ table
-- create a Domoticz variable, coded in json, within all variables used in this module
checkVar('zHeatPumpZone',2,json.encode(HPZ))
else
HPZ=json.decode(uservariables['zHeatPumpZone'])
HPZinit() -- check that all variables in HP table are initialized
end
if (timenow.min==0) then
-- shift temperatures in HPZ['tn'] and compute new tempDerivate
HPZ['t4']=HPZ['t3']
HPZ['t3']=HPZ['t2']
HPZ['t2']=HPZ['t1']
HPZ['t1']=HPZ['t0']
-- HPZ['t0']=otherdevices[TempZoneAlwaysOn]
HPZ['t0']=HPZ['temp']
HPZ['gr']=math.floor((HPZ['t0']-HPZ['t1'])/0.01+(HPZ['t1']-HPZ['t2'])/0.0125+(HPZ['t2']-HPZ['t3'])/0.015+(HPZ['t3']-HPZ['t4'])/0.02)/200
else
HPZ['temp']=math.floor((HPZ['temp']*3+otherdevices[TempZoneAlwaysOn])/0.04)/100
end
tempDerivate=HPZ['gr']
levelOld=HP['Level'] -- save previous level
--levelOld=2 --DEBUG
diffMax=0
for n,v in pairs(zones) do -- check that temperature setpoint exist
-- n=zone name, v=CSV separated by | containing tempsensor and electrovalve device name
checkVar('TempSet_'..v[ZONE_NAME],1,21)
-- check that devices exist
if (otherdevices[v[ZONE_TEMP_DEV] ]==nil) then
log(E_CRITICAL,'Zone '..v[ZONE_NAME]..': temperature sensor '..v[ZONE_TEMP_DEV]..' does not exist')
end
if (v[ZONE_RH_DEV] and v[ZONE_RH_DEV]~='' and otherdevices[v[ZONE_RH_DEV] ]==nil) then
log(E_CRITICAL,'Zone '..v[ZONE_NAME]..': relative humidity device '..v[ZONE_RH_DEV]..' defined in config_heatpump.lua but does not exist')
end
if (v[ZONE_VALVE] and v[ZONE_VALVE]~='' and otherdevices[v[ZONE_VALVE] ]==nil) then
log(E_CRITICAL,'Zone '..v[ZONE_NAME]..': valve device '..v[ZONE_VALVE]..' defined in config_heatpump.lua but does not exist')
end
end
if (otherdevices[tempHPout] == nil) then
log(E_CRITICAL,'Please create a temperature sensor named "'..tempHPout..'" that measures the temperature of fluid from heat pump to the radiant/coil system')
goto mainEnd
end
if (otherdevices[tempHPin] == nil) then
log(E_CRITICAL,'Please create a temperature sensor named "'..tempHPin..'" that measures the temperature of fluid from the radiant/coil system back to the heat pump')
goto mainEnd
end
valveState=''
valveStateTemp={}
tempFluidLimit=25 -- initialize value to avoid any error
gasHeaterOn=0
-- check outdoorTemperature
-- outdoorTemperature=string.gsub(otherdevices[tempOutdoor],';.*','')
-- outdoorTemperature=tonumber(outdoorTemperature) -- extract temperature, in case the device contains also humdity and/or pressure
--
-- find outdoorTemperature and outdoorHumidity : otherdevices[tempOutdoor] is like "temp;hum;0;baro;" "-2.70;89;0;1024;0"
for t, h in string.gmatch(otherdevices[tempOutdoor], "([%d.-]+);([%d.]+);.*") do
outdoorTemperature=tonumber(t)
outdoorHumidity=tonumber(h)
break
end
-- Also, I have to consider the availability of power from photovoltaic
if (otherdevices[powerMeter]~=nil) then
-- power meter exists, returning value "usagePower;totalEnergy"
for str in otherdevices[powerMeter]:gmatch("[^;]+") do
instPower=tonumber(str)
break
end
avgPower=uservariables['avgPower'] -- use the average power instead of instant power!
else
avgPower=500 -- power meter does not exist: set avgPower to 500W by default
end
prodPower=0-avgPower
hplevel='Off' -- Off, Auto, Dehum
hpforced=0 -- if 1, force heat pump working even if no energy from solar
if (HPmode ~= 'Winter' and HPmode ~= 'Summer') then
-- Both heating and cooling are disabled
HP['Level']=LEVEL_OFF
levelOld=LEVEL_OFF
heatingCoolingEnabled=0
else
-- Winter or Summer
if (HPLevel==nil or otherdevices[HPLevel]==nil) then
hplevel='Off'
elseif (otherdevices[HPLevel]=='Night') then
hplevel='Auto'
hpforced=1
elseif (otherdevices[HPLevel]=='NightDehum') then
hplevel='Dehum'
hpforced=1
end
if (HPmode~='Summer' and hplevel='Dehum') then
-- cannot dry in Winter mode => cancel dehumidification level
hplevel='Off'
commandArray[HPLevel]='Off'
end
end
-- hplevel='Off', 'Auto' or 'Dehum'
-- hpforced=0 (normal) or 1 (force ON always if not enough power is available from photovoltaic)
if (hplevel~⁼'Off') then
heatingCoolingEnabled=1
-- Heating or cooling is enabled
-- initialize some variables, depending by the HPmode variable)
if (HPmode == 'Winter') then
-- Heating enabled
log(E_INFO,'================================= Winter ================================')
zone_start=ZONE_WINTER_START -- offset on zones[] structure
zone_stop=ZONE_WINTER_STOP
zone_offset=ZONE_WINTER_OFFSET
zone_weight=ZONE_WINTER_WEIGHT
-- diffMaxHigh is used to define when room temperature is distant from the set point
-- diffMaxHigh=0.3 -- if diffMax<diffMaxHigh, temperature is near the set point
-- reduce diffMaxHigh if outdoor temperature is low (to use higher temperatures to heat the building)
diffMaxHigh=0.3+(HP['otmin']/40)+HP['otmax']/60
diffMaxHigh_power=500 -- if usage power > diffMaxHigh_power, Level will be decreased in case of comfort temperature (diffMax<diffMaxHigh)
prodPower_incLevel=300 --minimum production power to increment level
spOffset=OVERHEAT
else
-- Cooling enabled
log(E_INFO,'================================= Summer ================================')
zone_start=ZONE_SUMMER_START -- offset on zones[] structure
zone_stop=ZONE_SUMMER_STOP
zone_offset=ZONE_SUMMER_OFFSET
zone_weight=ZONE_SUMMER_WEIGHT
-- cooling enabled only if consumed power is < 200 Watt. It's tolerated to consume more than 200W only if room temperature > setpoint + 2°C
diffMaxHigh=2 -- if diffMax<diffMaxHigh, temperature is near the set point
diffMaxHigh_power=200 -- if usage power > diffMaxHigh_power, Level will be decreased in case of comfort temperature (diffMax<diffMaxHigh)
prodPower_incLevel=500 --minimum production power to increment level
spOffset=OVERCOOL
end
realdiffMax=-10
diffMax=-10 -- max weighted difference between room setpoint and temperature
rhMax=0 -- max value of relative humidity
-- rhMax=70 -- DEBUG: force RH to a high value to force dehumidification
zonesOn=0 -- number of zones that are ON
-- HP['SPoff']==offset added to set point based on available energy, to overheat/overcool in case of extra energy
if (HP['SPoff']==0) then
if (peakPower()==false and (prodPower>1200 or (HPmode == 'Winter' and prodPower>400 --[[ or HP['Level']==LEVEL_WINTER_MAX ]] ))) then -- more than 800W fed to the electrical grid, or more than 1000W avg power (excluding power used by aux loads, that can be disconnected)
HP['SPoff']=spOffset -- increase setpoint by OVERHEAT parameter to overheat, in case of extra available energy
log(E_INFO,"Enable OverHeating/Cooling")
end
else
log(E_INFO,"SPoff != 0")
if ((HPmode == 'Summer' and prodPower<0) or (HPmode == 'Winter' and avgPower>500 and instPower>500)) then
HP['SPoff']=0
log(E_INFO,"Disable OverHeating/Cooling")
end
end
-- check temperatures and setpoints
for n,v in pairs(zones) do
-- v[ZONE_NAME]=zonename (HeatingSP_n = setpoint temperature)
-- v[ZONE_TEMP_DEV]=tempsensor
-- v[ZONE_RH_DEV]=relative humidity sensor
-- v[ZONE_VALVE]=valve device
-- v[zone_start]=start time for comfort
-- v[zone_stop]=end time for comfort
-- v[zone_offset]=offset to be used during the night, used to tolerate a lower temperature when rooms are unused
-- v[zone_weight]=weight to calculate the weighted difference between setpoint and current temperature (for some rooms, maybe it's not so important to get exactly the temperature indicated by the SetPoint variable)
--
-- check temperature offset defined for each zone (used to reduce temperature during the night
temperatureOffset=0
if (timenow.hour < v[zone_start] or timenow.hour >= v[zone_stop]) then
-- night: reduce the temperature setpoint
temperatureOffset=v[zone_offset]
end
rh=0
if (v[ZONE_RH_DEV]~='' and otherdevices[v[ZONE_RH_DEV] ]~=nil) then
rh=tonumber(otherdevices[v[ZONE_RH_DEV] ]);
if (rh>rhMax) then rhMax=rh end
end
-- diff=(setpoint+offset)-temperature: if diff>0 => must heat
if (v[ZONE_TEMP_DEV]==TempZoneAlwaysOn) then
temp=HPZ['temp']
else
temp=tonumber(otherdevices[ v[ZONE_TEMP_DEV] ])
end
realdiff=uservariables['TempSet_'..v[ZONE_NAME]]+temperatureOffset-temp; -- tempSet-temp+temperatureOffsetZone
diff=realdiff+HP['SPoff'] -- tempSet-temp+temperatureOffsetZone+temperatureOffsetGlobal
if (HPmode ~= 'Winter') then
-- summer => invert diff
realdiff=0-realdiff -- TempSet+offset(nighttime)-Temp
diff=0-diff -- TempSet+offset(nighttime)+offset(power)-Temp increased when there is extra power from PV
end
if (diff>0) then
-- must heat/cool!
valveState='On'
diff=diff*v[zone_weight] -- compute the weighted difference between room temperature and setpoint
realdiff=realdiff*v[zone_weight]
zonesOn=zonesOn+1
else
-- temperature <= (setpoint+offset) => diff<=0
valveState='Off'
end
if (diff>diffMax) then
diffMax=diff -- store in diffMax the maximum value of room difference between setpoint and temperature
end
if (realdiff>realdiffMax) then
realdiffMax=realdiff -- store in diffMax the maximum value of room difference between setpoint and temperature
end
if (v[ZONE_VALVE]~=nil and v[ZONE_VALVE]~='') then
valveStateTemp[v[ZONE_VALVE] ]=valveState
end
if (valveState=='On') then
log(E_INFO,valveState..' zone='..v[ZONE_NAME]..' RH='..rh..' Temp='..temp..' SP='..uservariables['TempSet_'..v[ZONE_NAME]]..'+'..temperatureOffset..'+('..HP['SPoff']..') diff='..diff)
else
log(E_DEBUG,valveState..' zone='..v[ZONE_NAME]..' RH='..rh..' Temp='..temp..' SP='..uservariables['TempSet_'..v[ZONE_NAME]]..'+'..temperatureOffset..'+('..HP['SPoff']..') diff='..diff)
end
end
log(E_INFO,'tempDerivate='..tempDerivate..' diffMax='..diffMax..' diffMaxHigh='..diffMaxHigh..' RHMax='..rhMax)
-- set outdoorTemperatureMin (reset every midnight)
if (minutesnow==0 or HP['otmin']==nil or HP['otmin']>outdoorTemperature) then
HP['otmin']=outdoorTemperature
end
-- set outdoorTemperatureMax (reset every noon)
if (minutesnow==720 or HP['otmax']==nil or HP['otmax']<outdoorTemperature) then
HP['otmax']=outdoorTemperature
end
-- Also, I have to consider the availability of power from photovoltaic
if (otherdevices[powerMeter]~=nil) then
-- power meter exists, returning value "usagePower;totalEnergy"
-- Also, script_device_power.lua is writing the user variable avgPower with average consumed power in the minute
if (inverterMeter ~= '' and otherdevices[inverterMeter]~=nil) then
-- inverterMeter device exists: extract power (skip energy or other values, separated by ;)
for p in otherdevices[inverterMeter]:gmatch("[^;]+") do
inverterPower=tonumber(p)
break
end
log(E_INFO,"AveragePower:"..uservariables['avgPower'].."W InstPower="..instPower.." From PV:"..inverterPower.."W")
else
log(E_INFO,"AveragePower:"..uservariables['avgPower'].."W")
end
-- Level indicate how much power the heating/cooling system can use, for example:
-- Level 1 => dehumidifier ON (HeatPump ON, Ventilation ON, Ventilation chiller ON
-- Level 2 => + radiant system ON
-- Level 3 => + HeatPump full power
-- Level 4 => + HeatPump Fancoil temperature (use with care with radiant system!!) Disabled by defaul
-- TODO: dehumidification during winter: how? My stupid CMV needs cold water to do that!
if (HPmode == 'Summer' and rhMax>60 and HP['Level']==LEVEL_OFF and prodPower>1000) then
-- high humidity: activate heatpump + ventilation + chiller (Level 1)
incLevel()
end
if (minutesnow<timeofday['SunriseInMinutes']+180 and diffMax<diffMaxHigh) then
-- in the morning, if temperature is not so distant from the setpoint, try to not consume from the grid
diffMaxHigh_power=0
end
-- In the morning, if room temperature is almost ok, try to export power to help the electricity grid
if (diffMax<diffMaxHigh and peakPower()) then
log(E_INFO,"Try to export energy, or not consuming during the night")
diffMax=-10
end
if (diffMax>0) then
if (EVPOWER_DEV~=nil and EVPOWER_DEV~='') then
-- A device measuring electric vehicle charging power exists
-- POWER_MAX is a variable with the maximum power that the electricity meter can supply forever
-- Increase POWER_MAX by power used by EV charger (Heat Pump has higher priority, so the EV charger should reduce its current/power)
for str in otherdevices[EVPOWER_DEV]:gmatch("[^;]+") do -- get power from device ("POWER;ENERGY;..."
POWER_MAX=POWER_MAX+tonumber(str)
break
end
end
if (avgPower<POWER_MAX) then
-- must heat/cool!
-- check that fluid is not too high (Winter) or too low (Summer), else disactivate HeatPump_Fancoil output (to switch heatpump to radiant fluid, not coil fluid temperature
if (HPmode == 'Winter') then
-- make tempFluidLimit higher if rooms are cold
tempFluidLimit=28
-- if outdoor temperature > 28 => tempFluidLimit-=(outdoorTemperature-28)/3
-- outdoorTemperatureMin<10 => if min outdoor temperature is low, increase the fluid temperature from heatpump
tempFluidLimit=tempFluidLimit+(10-HP['otmin'])/4+diffMax*8-tempDerivate*10 -- Tf=30+(10-outdoorTempMin)/4+deltaT*10+tempDerivate*10 otmin=-6, deltaT=0.4 => Tf=30+4+3.2=37.2°C
if (tempFluidLimit>TEMP_WINTER_HP_MAX) then
tempFluidLimit=TEMP_WINTER_HP_MAX
end
elseif (HPmode == 'Summer') then
-- during the Summer
-- make tempFluidLimit lower if rooms are warm
tempFluidLimit=18
-- if outdoor temperature > 28 => tempFluidLimit-=(outdoorTemperature-28)/3
if (outdoorTemperature>28) then
tempFluidLimit=tempFluidLimit-(outdoorTemperature-28)/3
end
-- also, regulate fluid temperature in base of of DeltaT
tempFluidLimit=tempFluidLimit-diffMax
-- if (diffMax<0.5) then tempFluidLimit=tempFluidLimit+0.5 end
-- if (diffMax<=0.2) then tempFluidLimit=tempFluidLimit+0.5 end
if (tempFluidLimit<TEMP_SUMMER_HP_MIN) then
tempFluidLimit=TEMP_SUMMER_HP_MIN
end
end
if (prodPower>prodPower_incLevel) then
-- more available power => increment level
if (HP['Level']>=levelMax) then
-- already at full power => increase fluid temperature in Winter, or decrease in the Summer
if (HPmode == 'Winter') then
tempFluidLimit=tempFluidLimit+2
else
tempFluidLimit=tempFluidLimit-1
end
elseif (HP['Level']==0) then
-- start heat pump
incLevel()
end
else
-- prodPower<prodPower_incLevel
-- no extra power from photovoltaic
log(E_DEBUG,"No enough power from PV")
if (HPmode == 'Winter') then
-- winter
if (diffMax>diffMaxHigh or (diffMax>0 and (monthnow>10 or monthnow<3))) then
-- too much difference from set point => start heating even in case there is not enough power from PV
log(E_DEBUG,"Too far from setpoint")
if (HP['Level']==0) then incLevel() end
else
-- diffMax<diffMaxHigh: rooms almost in temperature
if (monthnow>=3 and monthnow<=10) then
if (HP['Level']>0) then
log(E_INFO,"From Mar to Oct, no enough power from PV and rooms almost in temperature => decLevel")
decLevel()
end -- From Apr to Oct, turn off Heat Pump if no available power from PV
else
-- from November to March, keep heat pump ON, but at low power (rooms are almost in temperature)
if (HP['Level']>1) then
log(E_INFO,"From Nov to Feb, no enough power from PV and rooms almost in temperature => Level=2 or 1")
decLevel()
end
end
end
else
-- summer
if (avgPower>diffMaxHigh_power) then
-- if usage power > diffMaxHigh_power, Level will be decreased in case of comfort temperature (diffMax<diffMaxHigh)
log(E_DEBUG,"Decrease heatpump power")
decLevel()
end
end
end
tempFluid=tonumber(otherdevices[tempHPout])
if (HP['Level']>0) then
-- regulate fluid tempeature in case of max Level
if (HPmode == 'Winter') then
-- tempHPout < tempFluidLimit => FANCOIL
-- tempFluidLimit < tempHPout < tempFluidLimit+2 => FULLPOWER
-- tempHPout > tempFluidLimit+2 or tempHPin > tempFluidLimit => HALFPOWER
-- check that fluid is not decreasing abnormally
if (tempFluid>HP['HPout']) then
if (tempFluid>=HP['HPout']+1) then
HP['HPout']=tempFluid
if (HP['HPout']>=TEMP_WINTER_HP_MAX+2) then
log(TELEGRAM_LEVEL,"Fluid temperature is too high!! "..HP['HPout'].."°C")
end
end
elseif (tempFluid<HP['HPout']-1) then
HP['HPout']=tempFluid
if (otherdevices[HPSummer]=='On') then
log(TELEGRAM_LEVEL, HPSummer.." was On => disable it")
commandArray[HPSummer]='Off'
end
if (HP['HPout']<=TEMP_SUMMER_HP_MIN) then
--fluid temperature is decreasing below a reasonable value => send alert
log(TELEGRAM_LEVEL,"Fluid temperature from heat pump is very low!! "..HP['HPout'].."°C")
end
end
if (tempFluid<=(tempFluidLimit-1)) then
-- must heat!
if (HP['Level']<LEVEL_WINTER_FANCOIL) then
log(E_INFO,"Fluid temperature is low => must heat!")
incLevel()
elseif (HP['Level']<levelMax and ( --[[ ((timenow.hour>=23 or timenow.hour<7) and inverterMeter~='' and HP['otmax']<5) or ]] prodPower>=prodPower_incLevel or diffMax>=diffMaxHigh)) then
log(E_INFO,"Enable full power!")
incLevel()
end
else
-- fluid temperature > tempFluidLimit-1 => assure that heatpump power is low
if (HP['Level']>LEVEL_WINTER_FANCOIL) then
log(E_INFO,"Fluid temperature almost equal to limit => reduce power")
decLevel()
end
if (tempFluid>tempFluidLimit+2 or tonumber(otherdevices[tempHPin])>tempFluidLimit) then
log(E_INFO,"Fluid temperature to radiant/coil > "..tempFluidLimit.." => switch to radiant temperature")
while (HP['Level']>=LEVEL_WINTER_FANCOIL) do decLevel() end
end
end
else -- Summer
-- check that fluid is not increasing/decreasing abnormally
if (tempFluid<HP['HPout']) then
if (tempFluid<HP['HPout']-1) then
HP['HPout']=tempFluid
if (HP['HPout']<=TEMP_SUMMER_HP_MIN-2) then
log(TELEGRAM_LEVEL,"Fluid temperature from heat pump is too low!! "..HP['HPout'].."°C")
end
end
elseif (tempFluid>HP['HPout']+1) then
HP['HPout']=tempFluid
if (otherdevices[HPSummer]=='Off' and otherdevices[HPOn]=='On') then
-- heat pump was ON, but heat pump Summer input was Off: that's strange, in summer season!
log(TELEGRAM_LEVEL,HPSummer.." was Off => enable it")
commandArray[HPSummer]='On'
end
if (HP['HPout']>=30) then
log(TELEGRAM_LEVEL,"Fluid temperature from heat pump is too high!! "..HP['HPout'].."°C")
end
end
if (tempFluid>tempFluidLimit) then
-- must cool!
if (prodPower>=prodPower_incLevel and HP['Level']<levelMax) then
-- enough power from photovoltaic to increase level
incLevel()
-- elseif (avgPower>diffMaxHigh_power) then
-- -- not enough power from photovoltaic -> reduce heat pump level
-- log(E_INFO,"Not enough power from PV")
-- decLevel()
end
else
log(E_INFO,"Fluid temperature to radiant/coil < "..tempFluidLimit.." => switch to radiant temperature")
while (HP['Level']>1) do decLevel() end
end
end
end -- if (HP['Level']>0
else --avgPower>=POWER_MAX: decrement level
log(E_INFO,"Too much power consumption => decrease Heat Pump level")
decLevel()
end
else
-- diffMax<=0 => All zones are in temperature!
-- if (HPmode == 'Winter' and HP['otmin']<4 and (tempDerivate*8)<diffMax) then
if (HPmode == 'Winter' and HP['otmin']<4 and (timenow.month<3 or timenow.month>10) and (tempDerivate*8)<diffMax) then
-- room temperature is decreasing: turn ON heat pump at minimum level, but only in the winter
log(E_INFO,"Room temperature is decreasing: start HeatPump with Level="..LEVEL_ON)
HP['Level']=LEVEL_ON
elseif (HP['Level']>LEVEL_OFF) then
-- temperature and humidity are OK
log(E_INFO,"All zones are in temperature! RHMax="..rhMax)
decLevel()
end
end
else
log(E_DEBUG,'No power meter installed')
end
if (GasHeater~=nil and GasHeater~='' and otherdevices[GasHeater]~=nil and HPmode == 'Winter') then
-- boiler exists: activate it during the night if outdoorTemperature<GHoutdoorTemperatureMax and if diffMax>=GHdiffMax
if (otherdevices[GasHeater]=='On') then
-- add some histeresys to prevent gas heater switching ON/OFF continuously
GHdiffMax=GHdiffMax-0.1
GHoutdoorTemperatureMax=GHoutdoorTemperatureMax+1
GHoutdoorHumidityMin=GHoutdoorHumidityMin-2
end
-- starts gas heater only few hours before 8:00 (because gas heater takes a short time to heat the fluid, in comparison to HP)
-- starts GH only if outdoor temperature is low and (outdoor humidity is high, or diffMax is high (HP is not able to heat enough))
if (outdoorHumidity<GHoutdoorHumidityMin) then
-- start gas heater only if diffMax > GHdiffMax+0.4 (we trust in heat pump!)
GHdiffMax=GHdiffMax+0.4
end
if (minutesnow<GHtimeMax and minutesnow>=GHtimeMin and diffMax>=GHdiffMax and outdoorTemperature<GHoutdoorTemperatureMax and diffMax>=GHdiffMax) then
-- high humidity: prefer to start gas heate
HP['Level']=LEVEL_OFF -- force heat pump off and use only gas heater, in the night
if (otherdevices[GasHeater]~='On') then
log(E_INFO,"Night, low outdoor temperature, high humidity => Starts gas heater")
gasHeaterOn=1
deviceOn(GasHeater,HP,'DG')
-- enable devices that must be enabled when gas heater is On
for n,v in pairs(GHdevicesToEnable) do
commandArray[v]='On'
end
end
else
if (otherdevices[GasHeater]~='Off' and (HP['dGH']~=nil and HP['dGH']=='a')) then
deviceOff(GasHeater,HP,'DG')
gasHeaterOn=0
for n,v in pairs(GHdevicesToEnable) do
commandArray[v]='Off'
end
end
end
if (otherdevices[GasHeater]=='On') then
-- gas heater on by script, or forced ON by user => disable heat pump
gasHeaterOn=1
decLevel()
decLevel()
decLevel()
decLevel()
end
end
end -- heatingCoolingEnabled=1
-- now scan DEVlist and enable/disable all devices based on the current level HP['Level']
if (HPmode == 'Winter') then
devLevel=2
if (minutesnow>=HPNightStart or minutesnow<HPNightEnd) then
-- during the night, go to the minimum level to reduce noise
levelMax=LEVEL_WINTER_MAX_NIGHT
end
elseif (HPmode == 'Summer') then
devLevel=4
if (otherdevices[HPLevel]=='Dehum') then
-- Dehumidification -> set HP to the minimum level
levelMax=1
else
levelMax=LEVEL_SUMMER_MAX
if (minutesnow>=HPNightStart or minutesnow<HPNightEnd) then
levelMax=LEVEL_SUMMER_MAX_NIGHT
end
end
else
devLevel=2 -- default: Winter
end
if (HP['Level']>levelMax) then
log(E_INFO,"Reduce Level to levelMax="..levelMax)
HP['Level']=levelMax
end
if (HP['Level']<levelOld) then
-- decLevel requested => reduce level only after N minutes where the system ask to reduce level
-- My heat pump works very bad if level switch between LEVEL_WINTER_MAX and LEVE_WINTER_MAX-1
if (HP['t']==nil or HP['t']>=3) then
HP['t']=0
else
HP['t']=HP['t']+1
end
log(E_INFO,"Level decrease requested, t="..HP['t'].."/3")
HP['Level']=levelOld
if (HP['t']==3) then
-- in the last 5 minutes, the system requested to reduce heat pump level
HP['t']=0
HP['Level']=levelOld-1
end
else
HP['t']=0
end
for n,v in pairs(DEVlist) do
-- n=table index
-- v={deviceName, winterLevel, summerLevel}
log(E_DEBUG,"DevName="..v[1].." devLevel="..v[devLevel].." CurrentLevel="..HP['Level'].." levelMax="..levelMax )
if (v[devLevel]<255) then -- if devLevel is set to 255, device should be ignored
-- v[devLevel]=START level
-- v[devLevel+1]=STOP level e.g. HeatPump_HalfPower: start level=1, stop level=2, so this device should be activated only when HP['level']==1
if (HP['Level']>=v[devLevel+1] or HP['Level']<v[devLevel]) then
-- this device has a level > of current level => disable it
deviceOff(v[1],HP,'d'..n)
else
-- this device has a level <= of current level => enable it
deviceOn(v[1],HP,'d'..n)
end
end
end
updateValves() -- enable/disable the valve for each zone
-- other customizations....
-- Make sure that radiant circuit is enabled when outside temperature goes down, or in winter, because heat pump starts to avoid any damage with low temperatures
if (outdoorTemperature<=4 or (HPmode=='Winter' and HP['Level']>LEVEL_OFF) or (HPmode=='Summer' and HP['Level']>=2) or GasHeaterOn==1) then
if (otherdevices['Valve_Radiant_Coil']~='On') then
commandArray['Valve_Radiant_Coil']='On'
HP['trc']=0
end
else
HP['trc']=HP['trc']+1
if (otherdevices['Valve_Radiant_Coil']~='Off' and HP['trc']>=3) then
commandArray['Valve_Radiant_Coil']='Off'
end
end
if (otherdevices[HPLevel]=='Dehum') then
-- force dehumidification only
deviceOff('Valve_Radiant_Coil') -- disable radiant => use only MVHR or fan coils
if (tempFluid>TEMP_SUMMER_HP_MIN) then
deviceOn('HeatPump_Fancoil',HP,'DF')
else
deviceOn('HeatPump_Fancoil',HP,'DF')
end
deviceOn(VENTILATION_COIL_DEV,HP,'DC')
if (tempFluid<=18) then -- activate chiller only if fluid temperature from heat pump is cold enough
deviceOn(VENTILATION_DEHUMIDIFY_DEV,HP,'DD')
elseif (tempFluid>=20) then
deviceOff(VENTILATION_DEHUMIDIFY_DEV,HP,'DD')
end
elseif (HPmode~='Summer' or HP['Level']==0) then
deviceOff(VENTILATION_COIL_DEV,HP,'DC')
deviceOff(VENTILATION_DEHUMIDIFY_DEV,HP,'DD')
elseif (HPmode=='Summer') then
-- Summer, and Level~=0
if (HP['Level']==levelMax) then
if (tempFluid<=18) then -- activate chiller only if fluid temperature from heat pump is cold enough
deviceOn(VENTILATION_DEHUMIDIFY_DEV,HP,'DD')
elseif (tempFluid>=20) then
deviceOff(VENTILATION_DEHUMIDIFY_DEV,HP,'DD')
end
else
deviceOff(VENTILATION_DEHUMIDIFY_DEV,HP,'DD')
end
end
-- save variables
log(E_INFO,'Level:'..levelOld..'->'..HP['Level']..' GH='..gasHeaterOn..' HPLimit='..string.format("%.1f", tempFluidLimit)..' HPout='..otherdevices[tempHPout]..' HPin='..otherdevices[tempHPin]..' Outdoor='..otherdevices[tempOutdoor])
commandArray['Variable:zHeatPump']=json.encode(HP)
commandArray['Variable:zHeatPumpZone']=json.encode(HPZ)
log(E_DEBUG,'zHeatPump='..json.encode(HP))
log(E_DEBUG,'zHeatPumpZone='..json.encode(HPZ))
::mainEnd::
return commandArray