config_heatpump_emmeti.lua
124 lines (110 loc) · 8.21 KB
/
config_heatpump_emmeti.lua
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
-- scripts/lua/config_heatingpump.lua - Configuration file for heating pump heater/cooler system
-- Written by Creasol, https://creasol.it - [email protected]
--
dofile "scripts/lua/globalvariables.lua" -- some variables common to all scripts
dofile "scripts/lua/globalfunctions.lua" -- some functions common to all scripts
-- Some constants
TEMP_HISTERESIS=0.1
TEMP_WINTER_HP_MAX=48 -- maximum fluid temperature from HP during the Winter
TEMP_SUMMER_HP_MIN=14 -- minimum fluid temperature from HP during the Summer
OVERHEAT=0.5 -- Increase temperature setpoint in case of available power from solar photovoltaic
OVERCOOL=-0.2 -- Decrease temperature setpoint in case of available power from solar photovoltaic
POWER_MAX=5500 -- Increment heat pump level only if consumed power is less than POWER_MAX
EVPOWER_DEV='EV Energy'
EVSTATE_DEV="EV State" -- EV state, used to know if vehicle is in charging state or not: "Dis", "Con", "Ch"
--GasHeater='GasHeater' -- Activate gas heater instead of heat pump when external temperature very low: set to '' if a boiler does not exist
GasHeater='' -- it's not cheaper not greener than PDC => manually enabled only if PDC is not able to keep the temperature
GRID_VOLTAGE='Inverter - AC Voltage' -- Device measuring house voltage: if above 248V, heatpump can consume all available power
powerMeter='PowerMeter Grid' -- device name of power meter, that measure consumed power from the electric grid (negative when photovoltaic produced more than house usage)
inverterMeter='PV_PowerMeter' -- Inverter output power (photovoltaic). Set to '' if not available
inverter2Meter='PV_Garden' -- Inverter for the 2nd renewable energy source. Set to '' if not available
heatpumpMeter='PowerMeter HeatPump' -- power meter that supply the heat pump ('' if not used)
TEMPHPOUT_DEV='Temp_HeatPumpFluidOut' -- Temperature of water produced by heat pump (before entering coils or underfloor radiant system)
TEMPHPIN_DEV= 'Temp_HeatPumpFluidIn' -- Temperature of water that exits from coils and/or underfloor radiant system, and gets into the Heat Pump again
tempOutdoor='Meteo outdoor' -- Temperature outdoor, or meteo sensor ("temp;humidity;pression;0")
HPOn='HeatPump' -- Device that enable/disable the heat pump (thermostat input?)
HPSummer='HeatPump_Summer' -- Device to set if HP must cooling instead of heating
HPMode='HeatPump_Mode' -- Selector switch for Off, Winter, Summer
HPLevel='HeatPump_Level' -- Selector switch to force a specific power level: Off, 1, 2, 3, ... Auto
HPStatus='HeatPump_Status' -- Virtual text device, where to write status data
HPStatusIDX=1723 -- IDX of the virtual text device HPStatus
HPStatus2IDX=2370 -- IDX of the virtual text device used in Energy Dashboard
HPCompressor='HeatPump - Compressor max' -- Device that set the max compressor level (0-100%)
HPCompressorNow='HeatPump - Compressor now' -- Device that set the max compressor level (0-100%)
HPTempOutlet='HeatPump - Temp. outlet' -- Outlet temperature
HPTempOutletComputed='HeatPump - Temp. outlet computed' -- Setpoint for the output temperature
HPTempWinterMin='HeatPump - Temp min outlet Winter' -- Device to set minimum outlet temperature for Winter (35°C)
HPTempWinterMinIDX=2045
HPTempWinterMax='HeatPump - Temp max outlet Winter' -- Device to set maximum outlet temperature for Winter (40°C)
HPTempWinterMaxIDX=2046
HPTempSummerMin='HeatPump - Temp min outlet Summer' -- Device to set minimum outlet temperature for Summer (15°C)
HPTempSummerMinIDX=2047
HPTempSummerMax='HeatPump - Temp max outlet Summer' -- Device to set maximum outlet temperature for Summer (17°C)
HPTempSummerMaxIDX=2048
-- fields for the following table
ZONE_NAME=1
ZONE_TEMP_DEV=2
ZONE_RH_DEV=3
ZONE_VALVE=4
ZONE_WINTER_START=5
ZONE_WINTER_STOP=6
ZONE_WINTER_OFFSET=7
ZONE_WINTER_WEIGHT=8
ZONE_SUMMER_START=9
ZONE_SUMMER_STOP=10
ZONE_SUMMER_OFFSET=11
ZONE_SUMMER_WEIGHT=12
-- heat pump working level
LEVEL_OFF=0 -- heat pump is completely OFF
LEVEL_ON=1 -- On, half power
DEVlist={
-- deviceName=name of each device involved in heating/cooling
-- winterLevel=heating level (0=OFF, 1=LOW, 2=MEDIUM, 3=HIGH)
-- summerLevel=cooling level (0=OFF, 1=LOW, 2=MEDIUM, 3=HIGH, 4=VERY HIGH)
-- First device MUST be the heat pump ON/OFF
-- *Level=10 or any value >=LEVEL_*_MAX+1 => always set OFF
-- *Level=255 => ignore
--'deviceName', winterLevel, summerLevel
-- start stop start stop
{'HeatPump', 1, 255, 1, 255 }, -- HeatPump input ON/OFF (thermostat input)
{'HeatPump_HalfPower', 1, 2, 1, 2 }, -- HeatPump input HalfPower (if On, works at 50% of nominal power)
{'HeatPump_Fancoil', 255, 255, 255, 255 }, -- HeatPump input Fancoil (set point for the fluid temperature: Off=use radiant, On=use coil with extreme temperatures
{'HeatPump_Summer', 255, 255, 1, 255 }, -- HeatPump input Summer (if On, the heat pump produce cold fluid) -- LEVEL_WINTER_MAX+1 => Always OFF
-- {'VMC_CaldoFreddo', 255, 255, 1, 255 }, -- Ventilation input coil: if On, the coil supplied by heat pump is enabled (to heat/cool air)
{'VMC_Deumidificazione', 255, 255, 255, 255 }, -- Ventilation input dryer: if On, the internal ciller is turned on to dehumidify air
}
HP_ON='HeatPump' -- device corresponding to heatpump on/off
zones={
-- start and stop indicates the comport period (hour of the day) when temperature must be equal to the setpoint
-- offset is the max tolerated difference from set temperature outside the comfort period
-- weight is used to set the importance of temperature in each rooms. 1=very important, 0.5 means that temperature can be a bit different from the set point, 0=ignore temperature in this room. If weight is less than 1, it's tolerated a greater offset in case there is not enough energy from renewable (photovoltaic)
--
-- for example: <---------- Winter --------> <---------- Summer ---------->
-- zone name temp device_name Rel.Hum device valve start stop offset weight start stop offset weight
-- ['Cucina']={ 'Temp_Cucina', 'RH_Cucina', '', 5, 22, 0.2, 1, 7, 23, 0.2, 1},
-- Zone name is "Cucina" (kitchen)
-- Temperature sensor is "Temp_Cucina"
-- RH sensor is "RH_Cucina"
-- No electrovalve for this room (always enabled)
-- During the winter, keep the setpoint from 5:00 to 22:00 (comfort period), and keep setpoint-0.2 (offset) outside the comfort period. This zone is really important, so weight=1
-- During the summer, keep setpoin from 7:00 to 23:00, then temperature can raise to setpoint+0.2. Weight is 1 (important zone)
--
-- <---------- Winter --------> <---------- Summer ---------->
-- zone name temp device_name Rel.Hum device valve start stop offset weight start stop offset weight
{'Cucina', 'Temp_Cucina', 'RH_Cucina', '', 4, 20, -0.2, 1, 7, 23, 0.2, 1},
{'Studio', 'Temp_Studio', '', '', 9, 18, -0.2, 0.2, 8, 19, 0.5, 0.8},
{'Bagno', 'Temp_Bagno', '', 'Valve_Bagno', 11, 21, -1, 0.3, 16, 19, 1, 0.5},
{'Camera', 'Temp_Camera', 'RH_Camera', 'Valve_Camera', 13, 22, -0.6, 0.5, 10, 23, 0.5, 0.8},
{'Camera_Valentina','Temp_Camera_Valentina','', 'Valve_Camera_Valentina', 13, 22, -0.8, 0.3, 13, 23, 0.5, 0.8},
{'Camera_Ospiti', 'Temp_Camera_Ospiti','', 'Valve_Camera_Ospiti', 13, 22, -0.8, 0.3, 13, 23, 0.5, 0.3},
{'Stireria', 'Temp_Stireria', '', 'Valve_Stireria', 13, 18, -1, 0.3, 8, 20, 1, 0.3},
}
-- Temperature device for a zone that is always active (used to compute gradients)
TempZoneAlwaysOn='Temp_Cucina'
-- GasHeater parameters
GHdiffMax=0.4 -- activate gas heater, during the night, if difference between setpoint and temperature is >0.4°C
GHoutdoorTemperatureMax=2 -- GasHeater disabled if outdoor temperature >= GHoutdoorTemperatureMax
GHoutdoorHumidityMin=88 -- Minimum outdoor humidity to start GasHeater, else start heat pump
GHtimeMin=300 -- Minutes from midnight when GasHeater will be enabled (or heatpump, if outdoor humidity is not high)
GHtimeMax=480 -- Minutes from midnight when GasHeater will be disabled
GHdevicesToEnable={} -- Device to enable when gas heater is ON {'devicename1','devicename2'}