Notifications
You must be signed in to change notification settings - Fork 0
/
Copy pathDataStore.cs
133 lines (128 loc) · 3.24 KB
/
DataStore.cs
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
using OpenHardwareMonitor.Hardware;
using System;
using System.Collections.Generic;
using System.Linq;
using System.Security.Principal;
using System.Text;
using System.Threading.Tasks;
namespace TMP
{
class DataStore
{
}
class StartProfile // manager values and how it should work
{
public static int
percentUpper = 50,
percentLower = 45,
percentStep = 5,
percentLimitMax = 90,
percentLimitMin = 10,
tempMax = 85,
tempMin = 30,
waitTime = 7500;
public static void ApplyViaCMD()
{
CMD.SetMaxState(false, (uint)percentUpper, false);
CMD.SetMaxState(true, (uint)percentUpper, false);
CMD.SetMinState(false, (uint)percentLower, false);
CMD.SetMinState(true, (uint)percentLower);
}
}
class Config
{
public static int
tempUpdateInterval = 200;
public static bool
managerRunning = false;
}
class Util
{
private static CpuDataReader CDR = new CpuDataReader();
public static float GetMaxTemp(bool doUpdate)
{
IEnumerable<float> valueCollection;
IReadOnlyDictionary<string, float> tempCollection = CDR.GetTemperaturesInCelsius(doUpdate);
valueCollection = tempCollection.Values;
float highestTemp = 0;
foreach (float i in valueCollection) if (i > highestTemp) highestTemp = i;
return highestTemp;
}
public static float GetClockSpeed(bool doUpdate)
{
return CDR.GetClockSpeed(doUpdate);
}
public static float GetLoad(bool doUpdate)
{
return CDR.GetLoad(doUpdate);
}
public static bool IsElevated()
{
return WindowsIdentity.GetCurrent().Owner
.IsWellKnown(WellKnownSidType.BuiltinAdministratorsSid);
//var id = WindowsIdentity.GetCurrent();
//return id.Owner != id.User;
}
}
internal sealed class CpuDataReader : IDisposable
{
private readonly Computer _computer;
public CpuDataReader()
{
_computer = new Computer { CPUEnabled = true };
_computer.Open();
}
Dictionary<string, float> coreAndTemperature = new Dictionary<string, float>();
float clockSpeed = 0f;
float load = 0f;
public void UpdateData()
{
coreAndTemperature.Clear();
clockSpeed = 0f;
load = 0f;
foreach (var hardware in _computer.Hardware)
{
hardware.Update();
if (!hardware.Name.Contains("Intel")) // only intel supported for now
return;
foreach (var sensor in hardware.Sensors)
{
if (sensor.SensorType == SensorType.Temperature && sensor.Value.HasValue)
coreAndTemperature.Add(sensor.Name, sensor.Value.Value);
else if (sensor.SensorType == SensorType.Clock && sensor.Value.HasValue
&& sensor.Name.Contains("CPU Core")
&& sensor.Value.Value > clockSpeed)
clockSpeed = sensor.Value.Value;
else if (sensor.SensorType == SensorType.Load && sensor.Value.HasValue)
load = sensor.Value.Value;
}
}
}
public IReadOnlyDictionary<string, float> GetTemperaturesInCelsius(bool doUpdate)
{
if (doUpdate) UpdateData();
return coreAndTemperature;
}
public float GetClockSpeed(bool doUpdate)
{
if (doUpdate) UpdateData();
return clockSpeed;
}
public float GetLoad(bool doUpdate)
{
if (doUpdate) UpdateData();
return load;
}
public void Dispose()
{
try
{
_computer.Close();
}
catch (Exception)
{
//ignore closing errors
}
}
}
}