The n command sets th Cube into pairing mode. There are 2 ways to invoke this command
Send n:
to the Cube, starts pairing mode without timeout. e.g
n:\r\n
Send n:
to the Cube, starts pairing mode with timeout (in seconds in HEX)
e.g with timeout of 60 sec (60 sec = 0003c in HEX)
n:003c\r\n
Important:
- you can stop pairing mode whith an 'x:' command
- Before reading the response message wait until the chosen timeout has appeared or you have stopped pairing mode whith an 'x:' command. If you don't do, it is possible that your response messages does not fit anymore to the corresponding commands because of an timeout while reading a response...
The N message provides information about newly paired MAX! devices. This response is given after pairing started with the n:
command.
N:Aw4VzExFUTAwMTUzNDD/
The N Message is a base64 decoded string. After decoding:
00000000 03 0e 15 cc 4c 45 51 30 30 31 35 33 34 30 ff |....LEQ0015340.|
Description Length Example Value
=====================================================================
DeviceType 1 03 = wallthermostat
RF address 3 0e15cc
Serial 10 LEQ0015340
unknown 1 ff