This guide details the migration plan to move from the IoTHub Python v1 code base to the new and improved v2 code base. Note that this guide assumes the use of asynchronous code.
- v1
pip install azure-iothub-device-client
- v2
pip install azure-iot-device
When creating a device client on the V1 client the protocol was specified on in the constructor. With the v2 SDK we are currently only supporting the MQTT protocol so it only requires to supply the connection string when you create the client.
- v1
from iothub_client import IoTHubClient, IoTHubClientError, IoTHubTransportProvider, IoTHubClientResult
from iothub_client import IoTHubMessage, IoTHubMessageDispositionResult, IoTHubError, DeviceMethodReturnValue
client = IoTHubClient(connection_string, IoTHubTransportProvider.MQTT)
- v2
from azure.iot.device.aio import IoTHubDeviceClient
from azure.iot.device import Message
client = IoTHubDeviceClient.create_from_connection_string(connection_string)
await device_client.connect()
For x.509 device the v1 SDK required the user to supply the certificates in a call to set_options. Moving forward in the v2 SDK, we only require for the user to call the create function with an x.509 object containing the path to the x.509 file and key file with the optional pass phrase if necessary.
- v1
from iothub_client import IoTHubClient, IoTHubClientError, IoTHubTransportProvider, IoTHubClientResult
from iothub_client import IoTHubMessage, IoTHubMessageDispositionResult, IoTHubError, DeviceMethodReturnValue
client = IoTHubClient(connection_string, IoTHubTransportProvider.MQTT)
# Get the x.509 certificate information
client.set_option("x509certificate", X509_CERTIFICATE)
client.set_option("x509privatekey", X509_PRIVATEKEY)
- v2
from azure.iot.device.aio import IoTHubDeviceClient
from azure.iot.device import Message
# Get the x.509 certificate path from the environment
x509 = X509(
cert_file=os.getenv("X509_CERT_FILE"),
key_file=os.getenv("X509_KEY_FILE"),
pass_phrase=os.getenv("X509_PASS_PHRASE")
)
client = IoTHubDeviceClient.create_from_x509_certificate(hostname=hostname, device_id=device_id, x509=x509)
await device_client.connect()
- v1
# create the device client
message = IoTHubMessage("telemetry message")
message.message_id = "message id"
message.correlation_id = "correlation-id"
prop_map = message.properties()
prop_map.add("property", "property_value")
client.send_event_async(message, send_confirmation_callback, user_ctx)
- v2
# create the device client
message = Message("telemetry message")
message.message_id = "message id"
message.correlation_id = "correlation id"
message.custom_properties["property"] = "property_value"
await client.send_message(message)
- v1
# create the device client
def receive_message_callback(message, counter):
global RECEIVE_CALLBACKS
message = message.get_bytearray()
size = len(message_buffer)
print ( "the data in the message received was : <<<%s>>> & Size=%d" % (message_buffer[:size].decode('utf-8'), size) )
map_properties = message.properties()
key_value_pair = map_properties.get_internals()
print ( "custom properties are: %s" % key_value_pair )
return IoTHubMessageDispositionResult.ACCEPTED
client.set_message_callback(message_listener_callback, RECEIVE_CONTEXT)
- v2
# create the device client
# define behavior for receiving a message
def message_handler(message):
print("the data in the message received was ")
print(message.data)
print("custom properties are")
print(message.custom_properties)
# set the message handler on the client
client.on_message_received = message_handler