import streamlit as st
def calculate_fuel_required(boiler_production_rate_ton, enthalpy_steam, enthalpy_water, boiler_efficiency, gas_calorific_value_btu_ft3):
"""
Calculates the fuel required to produce steam.
Args:
boiler_production_rate_ton: The production rate of the boiler in tons.
enthalpy_steam: The enthalpy of the steam in kilojoules per kilogram.
enthalpy_water: The enthalpy of the water in kilojoules per kilogram.
boiler_efficiency: The efficiency of the boiler as a fraction.
gas_calorific_value_btu_ft3: The calorific value of the gas in Btu per cubic foot.
Returns:
The fuel required in cubic meters, or None if there's a division by zero error.
"""
# Conversion factors
kg_per_ton = 1000
kilojoules_per_btu = 1.055
cubic_meters_per_ft3 = 0.0283168
# Convert production rate ton to kg
boiler_production_rate_kg = boiler_production_rate_ton * kg_per_ton
# Convert Btu/ft³ to J/m³
gas_calorific_value_kj_m3 = gas_calorific_value_btu_ft3 * kilojoules_per_btu / cubic_meters_per_ft3
try:
fuel_required = boiler_production_rate_kg * (enthalpy_steam - enthalpy_water) / (boiler_efficiency * gas_calorific_value_kj_m3)
return fuel_required
except ZeroDivisionError:
return None # Handle division by zero
st.title("Boiler N.G Fuel Calculator")
st.caption("By Eng. Alias @ [email protected]")
hide_menu_style = """
<style>
#MainMenu {visibility: hidden;}
</style>
"""
st.markdown(hide_menu_style, unsafe_allow_html=True)
hide_streamlit_style = """
<style>
#MainMenu {visibility: hidden;}
footer {visibility: hidden;}
</style>
"""
st.markdown(hide_streamlit_style, unsafe_allow_html=True)
# Get User Input with container
with st.container():
boiler_efficiency = st.number_input("Boiler Efficiency", min_value=0.0, max_value=1.0,value=0.9)
boiler_production_rate_ton = st.number_input("Boiler Steam Production Rate (ton)", min_value=0.0,value=50.0)
enthalpy_steam = st.number_input("Enthalpy of Steam Outlet (kJ/kg)", min_value=0.0,value=3230.0)
enthalpy_water = st.number_input("Enthalpy of Water Input (kJ/kg)", min_value=0.0,value=615.0)
gas_calorific_value_btu_ft3 = st.number_input("Fuel Gas Calorific Value (Btu/ft³)", min_value=0.0,value=1100.0)
if st.button("Calculate"):
fuel_required = calculate_fuel_required(boiler_production_rate_ton, enthalpy_steam, enthalpy_water, boiler_efficiency, gas_calorific_value_btu_ft3)
if fuel_required is not None:
st.info(f"Approximately Fuel Required: {fuel_required:.2f} m3 ")
else:
st.error("Error: check inputs values not zero ! ")