There is a significant level difference between octave smoothed and the raw data #175

Open
3ll3d00d opened this issue Dec 28, 2018 · 2 comments
Labels
question Further information is requested

Comments

@3ll3d00d
Copy link
Owner

Applying fractional octave smoothing lifts the level significantly, some of this is to be expected but the difference is really quite large so it needs further investigation to determine if this is correct and/or can be accounted for

@aron7awol
Copy link

This seems to vary with the fraction of the octave, which may suggest a math error somewhere? (I admit I haven't looked at the method of smoothing so it's a shot in the dark, but figured I'd share what I noticed in my very limited testing)

@3ll3d00d
Copy link
Owner Author

3ll3d00d commented Jan 3, 2019

that is to be expected because the size of each bucket is changing, basically smaller fraction means smaller bin means less signal (energy) per bin